Both views use the same certified data. This device remembers your choice.
HAIER heat pump efficiency: 38 outdoor models compared
HAIER has 38 heat pump outdoor models certified with this refrigerant group, in 2,395 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes HAIER makes. HAIER has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 38
- AHRI certifications
- 2,395
- Efficiency index
- 51%
- Typical model vs same-size, same-type peers (58 models)
- Meet CEE 2025
- 94.7%
- 36 models
How HAIER compares with comparable models
- HAIER
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index58 models scored | 51% | Not ranked | — |
| COP at 5°F58 models scored | 32% | Not ranked | 1.80 |
| Capacity retention at 5°F58 models scored | 62% | Not ranked | 80% |
| HSPF258 models scored | 68% | Not ranked | 9.5 |
| SEER258 models scored | 53% | Not ranked | 20.0 |
| EER258 models scored | 42% | Not ranked | 12.0 |
| Heating capacity at 5°F58 models scored | 64% | Not ranked | 19,950 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 94.7% | 36 |
| CEE 2026 Tier 1 (Split ASHP) | 84.2% | 32 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 81.6% | 31 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 71.1% | 27 |
Sizes and duct types offered
- HAIER (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 9 | 52% | 41% | 67% | 63% |
| Ducted, 2 tons | 6 | 45% | 35% | 70% | 48% |
| Ducted, 2.5 to 3 tons | 8 | 52% | 50% | 78% | 56% |
| Ducted, 3.5 to 4.5 tons | 7 | 54% | 50% | 77% | 63% |
| Ducted, 5 tons and up | 1 | 75% | 49% | 100% | 70% |
| Non-ducted, up to 1.5 tons | 14 | 49% | 20% | 60% | 51% |
| Non-ducted, 2 tons | 5 | 51% | 16% | 67% | 47% |
| Non-ducted, 2.5 to 3 tons | 5 | 45% | 16% | 62% | 36% |
| Non-ducted, 3.5 to 4.5 tons | 2 | 50% | 19% | 44% | 50% |
| Non-ducted, 5 tons and up | 1 | 68% | 18% | 89% | 55% |
Every HAIER model in the market
- HAIER models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
HAIER in the cold
- All listed models (median, middle 50% and 80%)
- HAIER (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HAIER, 47°F | 35 | 100% | 100% | 100% | 100% | 100% |
| HAIER, 17°F | 35 | 59% | 60% | 64% | 76% | 80% |
| HAIER, 5°F | 35 | 63% | 70% | 73% | 81% | 91% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HAIER, 47°F | 35 | 3.08 | 3.2 | 3.5 | 3.65 | 3.76 |
| HAIER, 17°F | 35 | 2.21 | 2.4 | 2.5 | 2.6 | 2.8 |
| HAIER, 5°F | 35 | 1.8 | 1.8 | 1.8 | 1.83 | 2.06 |
Source: NEEP ccASHP list · as of
Top HAIER models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AU60VFPTYAHaier | 5 tons60,000 Btu/h · Ducted | 82% | 2.00 | 11.0 | 53,000 | 16.8 | CEE 25CEE 26Xcel | 2 | 218394143 | Ducted, 5 tons and up | 81.8 |
| 2AU48VFPTYAHaier | 4 tons48,000 Btu/h · Ducted | 98% | 2.00 | 10.9 | 48,000 | 16.0 | CEE 25CEE 26Xcel | 2 | 218394142 | Ducted, 3.5 to 4.5 tons | 80.4 |
| 3AU36VFPTYAHaier | 3 tons36,000 Btu/h · Ducted | 95% | 2.00 | 13.5 | 39,000 | 18.0 | CEE 25CEE 26Xcel | 2 | 218394141 | Ducted, 2.5 to 3 tons | 79.1 |
| 41U36T3PC*HEHAIERwith ducted air handler PE(S,T)38J | 2.5 tons31,400 Btu/h · Ducted | 91% | 2.49 | 9.0 | 31,400 | 17.0 | CEE 25CEE 26XcelES CC | 186 | 218857292 | Ducted, 2.5 to 3 tons | 78.9 |
| 51U24T3PS*HEHAIERwith ducted air handler PE(S,T)35J | 2 tons21,800 Btu/h · Ducted | 87% | 2.47 | 9.0 | 19,900 | 17.0 | CEE 25CEE 26XcelES CC | 137 | 218857291 | Ducted, 2 tons | 74.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 11Q09RT2BE**HAIER · Arctic Singlewith ductless indoor unit US09AB2BE | 1 ton9,000 Btu/h · Non-ducted | 100% | 1.80 | 12.0 | 25.0 | 14.6 | CEE 25CEE 26XcelES CC | 5 | 218073018 | Non-ducted, up to 1.5 tons | 78.7 | 67.4 | 90.1 | 67.4 |
| 2AU36VFPTYAHaier | 3 tons35,600 Btu/h · Non-ducted | 98% | 2.00 | 10.8 | 22.0 | 14.4 | CEE 25CEE 26Xcel | 2 | 218394138 | Non-ducted, 2.5 to 3 tons | 76.7 | 74.4 | 79.0 | 74.4 |
| 3AU36VFPTYAHaier | 3 tons36,000 Btu/h · Ducted | 95% | 2.00 | 13.5 | 18.0 | 11.9 | CEE 25CEE 26Xcel | 2 | 218394141 | Ducted, 2.5 to 3 tons | 75.0 | 79.1 | 70.8 | 79.1 |
| 4AU60VFPTYAHaier | 5 tons60,000 Btu/h · Ducted | 82% | 2.00 | 11.0 | 16.8 | 11.5 | CEE 25CEE 26Xcel | 2 | 218394143 | Ducted, 5 tons and up | 74.8 | 81.8 | 67.8 | 81.8 |
| 5AU48VFPTYAHaier | 4 tons48,000 Btu/h · Non-ducted | 98% | 2.00 | 10.6 | 21.6 | 13.0 | CEE 25CEE 26Xcel | 2 | 218394139 | Non-ducted, 3.5 to 4.5 tons | 73.8 | 67.5 | 80.2 | 67.5 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | 1U36T3PC*HE | 2.49 | Ducted, 2.5 to 3 tons | 93% | 218857292 |
| Capacity retention at 5°F | AU60VFPTYA | 82% | Ducted, 5 tons and up | 97% | 218394143 |
| HSPF2 | AU36VFPTYA | 13.5 | Ducted, 2.5 to 3 tons | 100% | 218394141 |
| SEER2 | 1Q09RT2BE** | 27.0 | Non-ducted, up to 1.5 tons | 95% | 215876548 |
| EER2 | AU36VFPTYA | 14.4 | Non-ducted, 2.5 to 3 tons | 99% | 218394138 |
| Heating capacity at 5°F | 2Q20RT2BE** | 20,000 Btu/h | Ducted, up to 1.5 tons | 99% | 217021965 |
HAIER size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 68.4(50 is the typical model of its size class)2Q20RT2BE**9 of 9 models qualify · AHRI 217021965 | 66.8(50 is the typical model of its size class)1Q09RT2BE**with ducted air handler US09MB2BE9 of 9 models have all five ratings · AHRI 217036491 |
| Ducted, 2 tons | 74.5(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler PE(S,T)35J5 of 6 models qualify · AHRI 218857291 | 67.3(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler NAM30E3TA56 of 6 models have all five ratings · AHRI 217270222 |
| Ducted, 2.5 to 3 tons | 79.1(50 is the typical model of its size class)AU36VFPTYA6 of 8 models qualify · AHRI 218394141 | 75.0(50 is the typical model of its size class)AU36VFPTYA8 of 8 models have all five ratings · AHRI 218394141 |
| Ducted, 3.5 to 4.5 tons | 80.4(50 is the typical model of its size class)AU48VFPTYA5 of 7 models qualify · AHRI 218394142 | 70.2(50 is the typical model of its size class)AU48VFPTYA7 of 7 models have all five ratings · AHRI 218394142 |
| Ducted, 5 tons and up | 81.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394143 | 74.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394143 |
| Non-ducted, up to 1.5 tons | 67.4(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models qualify · AHRI 218073018 | 78.7(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models have all five ratings · AHRI 218073018 |
| Non-ducted, 2 tons | 62.9(50 is the typical model of its size class)3Q24RT2BE**4 of 5 models qualify · AHRI 217009757 | 68.8(50 is the typical model of its size class)3Q24RT2BE**5 of 5 models have all five ratings · AHRI 217009757 |
| Non-ducted, 2.5 to 3 tons | 74.4(50 is the typical model of its size class)AU36VFPTYA4 of 5 models qualify · AHRI 218394138 | 76.7(50 is the typical model of its size class)AU36VFPTYA5 of 5 models have all five ratings · AHRI 218394138 |
| Non-ducted, 3.5 to 4.5 tons | 67.5(50 is the typical model of its size class)AU48VFPTYA2 of 2 models qualify · AHRI 218394139 | 73.8(50 is the typical model of its size class)AU48VFPTYA2 of 2 models have all five ratings · AHRI 218394139 |
| Non-ducted, 5 tons and up | 64.2(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394140 | 68.0(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394140 |
Newest HAIER certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| 1U24T3PS*HEHAIERwith ducted air handler PE(S,T)27J | 1.5 tons20,600 Btu/h · Ducted | 2.35 | 88% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 137 | 218859859 |
| 1U36T3PC*HEHAIERwith ducted air handler PE(S,T)38J | 2.5 tons31,400 Btu/h · Ducted | 2.49 | 91% | 9.0 | 17.0 | CEE 25CEE 26XcelES CC | 186 | 218857292 |
| QS15H60HA5***HAIER · Connect 2026with indoor coil NCU[C,U]60DT5****+TDR and furnace NF97U135T5D | 4.5 tons53,000 Btu/h · Ducted | 1.70 | 71% | 7.9 | 14.3 | None | 120 | 218837969 |
| QS15H48HA5***HAIER · Connect 2026with indoor coil NCU[C,U]5060CT5****+TDR and furnace NF97U110T5C | 3.5 tons43,500 Btu/h · Ducted | 2.00 | 65% | 8.1 | 15.3 | CEE 25 | 304 | 218837949 |
| QS15H42HA5***HAIER · Connect 2026with indoor coil NCU[C,U]49CT5****+TDR and furnace NF97U110T5C | 3.5 tons42,000 Btu/h · Ducted | 2.00 | 65% | 7.9 | 15.8 | CEE 25 | 244 | 218837938 |
Compare HAIER
HAIER includes these brand names as listed in AHRI: HAIER. Standards are checked against published thresholds; program rules beyond ratings are not checked.