Skip to content

EXNOS vs HAIER heat pumps

Measured against models of the same size and duct type, HAIER scores higher on 5 of the 6 ratings. EXNOS has 38 outdoor models, HAIER has 38 outdoor models. EXNOS and HAIER have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
EXNOS and HAIER on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, HAIER scores higher on 5 of the 6 ratings.
  • EXNOS
  • HAIER
  • Other ranked manufacturers
EXNOSHAIER

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingEXNOSHAIER
Efficiency index33%median —51%median —
COP at 5°F36% (higher)median 1.8030% (higher)median 1.80
Capacity retention at 5°F31%median 70%62%median 80%
HSPF243%median 9.568%median 9.5
SEER231%median 20.054%median 20.0
EER227%median 10.542%median 12.0
Heating capacity at 5°F38%median 9,500 Btu/h64%median 20,100 Btu/h
Outdoor models3838
AHRI certifications382,391

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardEXNOSHAIER
CEE 2025 Tier 1 (Split ASHP)63.2%24 models94.7%36 models
CEE 2026 Tier 1 (Split ASHP)60.5%23 models84.2%32 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)50%19 models81.6%31 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models71.1%27 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 4 groups where both have models
  • EXNOS
  • HAIER
  • All models of the group
Ducted, up to 1.5 tons1.901,902 modelsDucted, 2 tons2.001,132 modelsDucted, 2.5–3 tons2.002,029 modelsDucted, 3.5–4.5 tons2.002,290 modelsDucted, 5 tons and up2.00341 modelsNon-ducted, up to 1.5 tons1.943,990 modelsNon-ducted, 2 tons2.00987 modelsNon-ducted, 2.5–3 tons2.001,210 modelsNon-ducted, 3.5–4.5 tons2.00591 modelsNon-ducted, 5 tons and up2.0588 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeEXNOSHAIER
Ducted, up to 1.5 tonsNone9 · index 52%
Ducted, 2 tonsNone6 · index 45%
Ducted, 2.5–3 tonsNone8 · index 52%
Ducted, 3.5–4.5 tonsNone7 · index 54%
Ducted, 5 tons and upNone1 · index 75%
Non-ducted, up to 1.5 tons27 · index 34%14 · index 49%
Non-ducted, 2 tons5 · index 28%5 · index 51%
Non-ducted, 2.5–3 tons5 · index 30%5 · index 45%
Non-ducted, 3.5–4.5 tons1 · index 27%2 · index 50%
Non-ducted, 5 tons and upNone1 · index 68%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeEXNOSCold-climate score, best modelHAIERCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class68.4(50 is the typical model of its size class)2Q20RT2BE**9 of 9 models qualify · AHRI 217021965
Ducted, 2 tonsNo models in this size class64.7(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler NAM24V1TA55 of 6 models qualify · AHRI 217269589
Ducted, 2.5–3 tonsNo models in this size class79.0(50 is the typical model of its size class)AU36VFPTYA6 of 8 models qualify · AHRI 218394141
Ducted, 3.5–4.5 tonsNo models in this size class80.4(50 is the typical model of its size class)AU48VFPTYA5 of 7 models qualify · AHRI 218394142
Ducted, 5 tons and upNo models in this size class81.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394143
Non-ducted, up to 1.5 tons70.0(50 is the typical model of its size class) (higher)T20230W20E12Also listed as T18230W2016 of 27 models qualify · AHRI 21808340667.3(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models qualify · AHRI 218073018
Non-ducted, 2 tonsNone on this board (0 of 5 models qualify)62.8(50 is the typical model of its size class)3Q24RT2BE**4 of 5 models qualify · AHRI 217009757
Non-ducted, 2.5–3 tons48.4(50 is the typical model of its size class)T28230W20E112 of 5 models qualify · AHRI 21808848874.1(50 is the typical model of its size class) (higher)AU36VFPTYA4 of 5 models qualify · AHRI 218394138
Non-ducted, 3.5–4.5 tons24.6(50 is the typical model of its size class)T42230W20E111 of 1 models qualify · AHRI 21808849067.5(50 is the typical model of its size class) (higher)AU48VFPTYA2 of 2 models qualify · AHRI 218394139
Non-ducted, 5 tons and upNo models in this size class64.2(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394140

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeEXNOSAll-around score, best modelHAIERAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class66.8(50 is the typical model of its size class)1Q09RT2BE**with ducted air handler US09MB2BE9 of 9 models have all five ratings · AHRI 217036491
Ducted, 2 tonsNo models in this size class67.2(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler NAM30E3TA56 of 6 models have all five ratings · AHRI 217270222
Ducted, 2.5–3 tonsNo models in this size class75.0(50 is the typical model of its size class)AU36VFPTYA8 of 8 models have all five ratings · AHRI 218394141
Ducted, 3.5–4.5 tonsNo models in this size class70.2(50 is the typical model of its size class)AU48VFPTYA7 of 7 models have all five ratings · AHRI 218394142
Ducted, 5 tons and upNo models in this size class74.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394143
Non-ducted, up to 1.5 tons73.8(50 is the typical model of its size class)T20230W20E12Also listed as T18230W2027 of 27 models have all five ratings · AHRI 21808340678.7(50 is the typical model of its size class) (higher)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models have all five ratings · AHRI 218073018
Non-ducted, 2 tons41.0(50 is the typical model of its size class)A24230W20E12with ductless indoor unit A24230N20E12Also listed as A24230W208225 of 5 models have all five ratings · AHRI 21808339568.5(50 is the typical model of its size class) (higher)3Q24RT2BE**5 of 5 models have all five ratings · AHRI 217009757
Non-ducted, 2.5–3 tons39.9(50 is the typical model of its size class)T28230W20E115 of 5 models have all five ratings · AHRI 21808848876.5(50 is the typical model of its size class) (higher)AU36VFPTYA5 of 5 models have all five ratings · AHRI 218394138
Non-ducted, 3.5–4.5 tons26.9(50 is the typical model of its size class)T42230W20E111 of 1 models have all five ratings · AHRI 21808849073.9(50 is the typical model of its size class) (higher)AU48VFPTYA2 of 2 models have all five ratings · AHRI 218394139
Non-ducted, 5 tons and upNo models in this size class67.9(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394140

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingEXNOSHAIER
COP at 5°Fbeats 87% · 2.10A36230W20E12Also listed as A36230W20822Non-ducted, 2.5–3 tonsbeats 89% · 2.30QS15H36HA5***Ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 63% · 80%T20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tonsbeats 97% · 82%AU60VFPTYADucted, 5 tons and up
HSPF2beats 81% · 10.5T20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tonsbeats 100% · 13.5AU36VFPTYADucted, 2.5–3 tons
SEER2beats 77% · 24.0T20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tonsbeats 95% · 27.01Q09RT2BE**Non-ducted, up to 1.5 tons
EER2beats 72% · 13.0T20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tonsbeats 99% · 14.4AU36VFPTYANon-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 89% · 16,000 Btu/hT20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tonsbeats 99% · 20,000 Btu/h2Q20RT2BE**Ducted, up to 1.5 tons

More comparisons