Skip to content

HAIER vs Kerr heat pumps

Measured against models of the same size and duct type, Kerr scores higher on 6 of the 6 ratings. HAIER has 38 outdoor models, Kerr has 38 outdoor models. HAIER and Kerr have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
HAIER and Kerr on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Kerr scores higher on 6 of the 6 ratings.
  • HAIER
  • Kerr
  • Other ranked manufacturers
HAIERKerr

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHAIERKerr
Efficiency index51%median —67%median —
COP at 5°F32%median 1.8059%median 2.00
Capacity retention at 5°F62%median 80%78%median 95%
HSPF268%median 9.579%median 10.0
SEER253%median 20.064%median 19.5
EER242%median 12.064%median 11.9
Heating capacity at 5°F64%median 19,950 Btu/h74%median 18,500 Btu/h
Outdoor models3838
AHRI certifications2,395113

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHAIERKerr
CEE 2025 Tier 1 (Split ASHP)94.7%36 models78.9%30 models
CEE 2026 Tier 1 (Split ASHP)84.2%32 models76.3%29 models
CEE Advanced Tier (Split ASHP)0%0 models2.6%1 models
Xcel Energy Colorado cold-climate ASHP (2025)81.6%31 models89.5%34 models
DOE Cold Climate Heat Pump Challenge0%0 models2.6%1 models
ENERGY STAR Cold Climate71.1%27 models89.5%34 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • HAIER
  • Kerr
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHAIERKerr
Ducted, up to 1.5 tons9 · index 52%7 · index 76%
Ducted, 2 tons6 · index 45%3 · index 60%
Ducted, 2.5 to 3 tons8 · index 52%7 · index 66%
Ducted, 3.5 to 4.5 tons7 · index 54%5 · index 62%
Ducted, 5 tons and up1 · index 75%None
Non-ducted, up to 1.5 tons14 · index 49%18 · index 67%
Non-ducted, 2 tons5 · index 51%3 · index 60%
Non-ducted, 2.5 to 3 tons5 · index 45%3 · index 68%
Non-ducted, 3.5 to 4.5 tons2 · index 50%2 · index 67%
Non-ducted, 5 tons and up1 · index 68%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHAIERCold-climate score, best modelKerrCold-climate score, best model
Ducted, up to 1.5 tons68.4(50 is the typical model of its size class)2Q20RT2BE**9 of 9 models qualify · AHRI 21702196582.9(50 is the typical model of its size class) (higher)A-KHP18SA-1with ducted air handler B-KHP18DA-17 of 7 models qualify · AHRI 217482433
Ducted, 2 tons74.5(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler PE(S,T)35J5 of 6 models qualify · AHRI 21885729185.8(50 is the typical model of its size class) (higher)A-KHP24SA-1with ducted air handler B-KHP24DA-13 of 3 models qualify · AHRI 217482436
Ducted, 2.5 to 3 tons79.1(50 is the typical model of its size class)AU36VFPTYA6 of 8 models qualify · AHRI 21839414182.7(50 is the typical model of its size class) (higher)A-KHP365A-17 of 7 models qualify · AHRI 216097146
Ducted, 3.5 to 4.5 tons80.4(50 is the typical model of its size class)AU48VFPTYA5 of 7 models qualify · AHRI 21839414282.6(50 is the typical model of its size class) (higher)A-KHP486A-15 of 5 models qualify · AHRI 216097150
Ducted, 5 tons and up81.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394143No models in this size class
Non-ducted, up to 1.5 tons67.4(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models qualify · AHRI 21807301897.0(50 is the typical model of its size class) (higher)A-KHP06SA-1with ductless indoor unit B-KHP06SA-112 of 18 models qualify · AHRI 216097110
Non-ducted, 2 tons62.9(50 is the typical model of its size class)3Q24RT2BE**4 of 5 models qualify · AHRI 21700975790.1(50 is the typical model of its size class) (higher)A-KHP24SA-1with ductless indoor unit B-KHP24CA-13 of 3 models qualify · AHRI 217482434
Non-ducted, 2.5 to 3 tons74.4(50 is the typical model of its size class)AU36VFPTYA4 of 5 models qualify · AHRI 21839413878.3(50 is the typical model of its size class) (higher)A-KHP365A-13 of 3 models qualify · AHRI 216097148
Non-ducted, 3.5 to 4.5 tons67.5(50 is the typical model of its size class)AU48VFPTYA2 of 2 models qualify · AHRI 21839413973.6(50 is the typical model of its size class) (higher)A-KHP486A-12 of 2 models qualify · AHRI 216097152
Non-ducted, 5 tons and up64.2(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394140No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHAIERAll-around score, best modelKerrAll-around score, best model
Ducted, up to 1.5 tons66.8(50 is the typical model of its size class)1Q09RT2BE**with ducted air handler US09MB2BE9 of 9 models have all five ratings · AHRI 21703649187.0(50 is the typical model of its size class) (higher)A-KHP09SA-1with ducted air handler B-KHP09DA-17 of 7 models have all five ratings · AHRI 217482423
Ducted, 2 tons67.3(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler NAM30E3TA56 of 6 models have all five ratings · AHRI 21727022278.6(50 is the typical model of its size class) (higher)A-KHP24SA-1with ducted air handler B-KHP24DA-13 of 3 models have all five ratings · AHRI 217482436
Ducted, 2.5 to 3 tons75.0(50 is the typical model of its size class)AU36VFPTYA8 of 8 models have all five ratings · AHRI 21839414183.9(50 is the typical model of its size class) (higher)A-KHP365A-17 of 7 models have all five ratings · AHRI 216097146
Ducted, 3.5 to 4.5 tons70.2(50 is the typical model of its size class)AU48VFPTYA7 of 7 models have all five ratings · AHRI 21839414284.3(50 is the typical model of its size class) (higher)A-KHP486A-15 of 5 models have all five ratings · AHRI 216097150
Ducted, 5 tons and up74.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394143No models in this size class
Non-ducted, up to 1.5 tons78.7(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models have all five ratings · AHRI 21807301896.6(50 is the typical model of its size class) (higher)A-KHP06SA-1with ductless indoor unit B-KHP06SA-116 of 18 models have all five ratings · AHRI 216097110
Non-ducted, 2 tons68.8(50 is the typical model of its size class)3Q24RT2BE**5 of 5 models have all five ratings · AHRI 21700975778.3(50 is the typical model of its size class) (higher)A-KHP24SA-1with ductless indoor unit B-KHP24SA-1Also listed as A-ZKP24SA-13 of 3 models have all five ratings · AHRI 216097114
Non-ducted, 2.5 to 3 tons76.7(50 is the typical model of its size class)AU36VFPTYA5 of 5 models have all five ratings · AHRI 21839413878.8(50 is the typical model of its size class) (higher)A-KHP365A-13 of 3 models have all five ratings · AHRI 216097145
Non-ducted, 3.5 to 4.5 tons73.8(50 is the typical model of its size class)AU48VFPTYA2 of 2 models have all five ratings · AHRI 21839413975.4(50 is the typical model of its size class) (higher)A-KHP486A-12 of 2 models have all five ratings · AHRI 216097149
Non-ducted, 5 tons and up68.0(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394140No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHAIERKerr
COP at 5°Fbeats 93% · 2.491U36T3PC*HEDucted, 2.5 to 3 tonsbeats 97% · 2.40A-KHP06SA-1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 82%AU60VFPTYADucted, 5 tons and upbeats 100% · 150%A-KZP06SA-1Also listed as A-ZKP06SA-1Non-ducted, up to 1.5 tons
HSPF2beats 100% · 13.5AU36VFPTYADucted, 2.5 to 3 tonsbeats 100% · 15.6A-KZP06SA-1Also listed as A-ZKP06SA-1Non-ducted, up to 1.5 tons
SEER2beats 95% · 27.01Q09RT2BE**Non-ducted, up to 1.5 tonsbeats 100% · 27.0A-ZKP15SA-1Ducted, up to 1.5 tons
EER2beats 99% · 14.4AU36VFPTYANon-ducted, 2.5 to 3 tonsbeats 99% · 18.0A-KHP06SA-1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 20,000 Btu/h2Q20RT2BE**Ducted, up to 1.5 tonsbeats 99% · 22,600 Btu/hA-KZP18SA-1Also listed as A-ZKP18SA-1Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
HAIER vs Kerr: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • HAIER (median, middle 50%)
  • Kerr (median, middle 50%)
Heating capacity, % of its 47°F maximum73%78%COP at maximum capacity1.802.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
HAIER: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
HAIER, 47°F35100%100%100%100%100%
HAIER, 17°F3559%60%64%76%80%
HAIER, 5°F3563%70%73%81%91%
HAIER: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
HAIER, 47°F353.083.23.53.653.76
HAIER, 17°F352.212.42.52.62.8
HAIER, 5°F351.81.81.81.832.06
Kerr: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Kerr, 47°F38100%100%100%100%100%
Kerr, 17°F3868%74%80%85%92%
Kerr, 5°F3857%72%78%81%82%
Kerr: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Kerr, 47°F382.843.053.193.33.46
Kerr, 17°F3822.172.262.42.6
Kerr, 5°F381.851.9222.12.34

Source: NEEP ccASHP list · as of