AURUS vs LUORISE heat pumps

Measured against models of the same size and duct type, AURUS scores higher on 5 of the 6 ratings. AURUS has 12 outdoor models, LUORISE has 12 outdoor models. AURUS and LUORISE have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AURUS and LUORISE on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AURUS scores higher on 5 of the 6 ratings.
  • AURUS
  • LUORISE
  • Other ranked manufacturers
AURUSLUORISE

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAURUSLUORISE
Efficiency index36% (higher)median —23% (higher)median —
COP at 5°F39% (higher)median 1.8024% (higher)median 1.80
Capacity retention at 5°F41% (higher)median 69%35% (higher)median 70%
HSPF230% (higher)median 8.518% (higher)median 8.5
SEER241% (higher)median 19.026% (higher)median 19.0
EER215%median 10.015%median 10.0
Heating capacity at 5°F50% (higher)median 15,000 Btu/h34% (higher)median 8,600 Btu/h
Outdoor models1212
AHRI certifications1212

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAURUSLUORISE
CEE 2025 Tier 1 (Split ASHP)50%6 models83.3%10 models
CEE 2026 Tier 1 (Split ASHP)41.7%5 models66.7%8 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)33.3%4 models66.7%8 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 2 groups where both have models
  • AURUS
  • LUORISE
  • All models of the group
Ducted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAURUSLUORISE
Ducted, 2 tons1 · index 48%None
Ducted, 2.5 to 3 tons1 · index 63%None
Ducted, 3.5 to 4.5 tons2 · index 51%None
Non-ducted, up to 1.5 tons6 · index 20%10 · index 22%
Non-ducted, 2 tons2 · index 26%2 · index 26%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAURUSCold-climate score, best modelLUORISECold-climate score, best model
Ducted, 2 tons62.1(50 is the typical model of its size class)ARU-H24CD/INVS-USwith ducted air handler ARU-H24AH/INVS-US1 of 1 models qualify · AHRI 208842390No models in this size class
Ducted, 2.5 to 3 tons75.2(50 is the typical model of its size class)ARU-H36CD/INVS-USwith ducted air handler ARU-H36AH/INVS-US1 of 1 models qualify · AHRI 208842391No models in this size class
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tons30.5(50 is the typical model of its size class)ARU-H12A1/INVL-US2with ductless indoor unit ARU-H12A1/INVL-US2Also listed as ARU-H12A2/INVL-US22 of 6 models qualify · AHRI 21061010330.5(50 is the typical model of its size class)L01-12K1V-19S-P-Owith ductless indoor unit L01-12K1V-19S-WC-IAlso listed as L01-12K1V-19S-O, L01-12K2V-19S-P-O, L01-12K2V-19S-O8 of 10 models qualify · AHRI 214390714
Non-ducted, 2 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAURUSAll-around score, best modelLUORISEAll-around score, best model
Ducted, 2 tons48.4(50 is the typical model of its size class)ARU-H24CD/INVS-USwith ducted air handler ARU-H24AH/INVS-US1 of 1 models have all five ratings · AHRI 208842390No models in this size class
Ducted, 2.5 to 3 tons63.1(50 is the typical model of its size class)ARU-H36CD/INVS-USwith ducted air handler ARU-H36AH/INVS-US1 of 1 models have all five ratings · AHRI 208842391No models in this size class
Ducted, 3.5 to 4.5 tons57.1(50 is the typical model of its size class)ARU-H48CD/INVS-USwith ducted air handler ARU-H48AH/INVS-US2 of 2 models have all five ratings · AHRI 208842392No models in this size class
Non-ducted, up to 1.5 tons24.8(50 is the typical model of its size class)ARU-H12A1/INVL-US2with ductless indoor unit ARU-H12A1/INVL-US2Also listed as ARU-H12A2/INVL-US24 of 6 models have all five ratings · AHRI 21061010324.8(50 is the typical model of its size class)L01-12K1V-19S-P-Owith ductless indoor unit L01-12K1V-19S-WC-IAlso listed as L01-12K1V-19S-O, L01-12K2V-19S-P-O, L01-12K2V-19S-O10 of 10 models have all five ratings · AHRI 214390714
Non-ducted, 2 tons26.1(50 is the typical model of its size class)ARU-H24A2/INVL-US2with ductless indoor unit ARU-H24A2/INVL-US21 of 2 models have all five ratings · AHRI 21061010626.1(50 is the typical model of its size class)L01-24K2V-19S-P-Owith ductless indoor unit L01-24K2V-19S-WC-IAlso listed as L01-24K2V-19S-O2 of 2 models have all five ratings · AHRI 214390722

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAURUSLUORISE
COP at 5°Fbeats 75% · 2.05ARU-H36CD/INVS-USDucted, 2.5 to 3 tonsbeats 31% · 1.80L01-24K2V-19S-P-OAlso listed as L01-24K2V-19S-ONon-ducted, 2 tons
Capacity retention at 5°Fbeats 64% · 76%ARU-H36CD/INVS-USDucted, 2.5 to 3 tonsbeats 48% · 70%L01-12K1V-19S-P-OAlso listed as L01-12K1V-19S-O, L01-12K2V-19S-P-O, L01-12K2V-19S-ONon-ducted, up to 1.5 tons
HSPF2beats 83% · 9.5ARU-H36CD/INVS-USDucted, 2.5 to 3 tonsbeats 21% · 8.5L01-24K2V-19S-P-OAlso listed as L01-24K2V-19S-ONon-ducted, 2 tons
SEER2beats 82% · 17.5ARU-H48CD/INVS-USDucted, 3.5 to 4.5 tonsbeats 36% · 19.0L01-24K2V-19S-P-OAlso listed as L01-24K2V-19S-ONon-ducted, 2 tons
EER2beats 29% · 10.1ARU-H48CD/INVS-USDucted, 3.5 to 4.5 tonsbeats 24% · 10.0L01-24K2V-19S-P-OAlso listed as L01-24K2V-19S-ONon-ducted, 2 tons
Heating capacity at 5°Fbeats 64% · 26,000 Btu/hARU-H36CD/INVS-USDucted, 2.5 to 3 tonsbeats 62% · 11,600 Btu/hL01-18K2V-19S-P-OAlso listed as L01-18K2V-19S-ONon-ducted, up to 1.5 tons