Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AURUS vs LUORISE heat pumps
Measured against models of the same size and duct type, AURUS and LUORISE split the 6 ratings 3–3. AURUS has 12 outdoor models, LUORISE has 27 outdoor models. AURUS and LUORISE have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AURUS
- LUORISE
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AURUS | LUORISE |
|---|---|---|
| Efficiency index | 32% (higher)median — | 30% (higher)median — |
| COP at 5°F | 41% (higher)median 1.85 | 31% (higher)median 1.90 |
| Capacity retention at 5°F | 21%median 70% | 30%median 71% |
| HSPF2 | 35%median 9.5 | 42%median 9.5 |
| SEER2 | 31% (higher)median 17.0 | 28% (higher)median 20.0 |
| EER2 | 27% (higher)median 9.5 | 21% (higher)median 9.5 |
| Heating capacity at 5°F | 32%median 9,100 Btu/h | 36%median 12,000 Btu/h |
| Outdoor models | 12 | 27 |
| AHRI certifications | 12 | 27 |
Share of models meeting each standard
| Standard | AURUS | LUORISE |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.3%4 models | 48.1%13 models |
| CEE 2026 Tier 1 (Split ASHP) | 33.3%4 models | 48.1%13 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 33.3%4 models | 51.9%14 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 33.3%4 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AURUS
- LUORISE
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AURUS | LUORISE |
|---|---|---|
| Non-ducted, up to 1.5 tons | 8 · index 35% | 16 · index 33% |
| Non-ducted, 2 tons | 2 · index 31% | 6 · index 24% |
| Non-ducted, 2.5–3 tons | 2 · index 8% | 4 · index 26% |
| Non-ducted, 3.5–4.5 tons | None | 1 · index 27% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AURUSCold-climate score, best model | LUORISECold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 59.5(50 is the typical model of its size class)ARU454-H12A2/INVL-US2with ductless indoor unit ARU454-H12A2/INVL-US23 of 8 models qualify · AHRI 216980959 | 62.1(50 is the typical model of its size class) (higher)L01-2Z-18K2V-20S-O8 of 16 models qualify · AHRI 218046436 |
| Non-ducted, 2 tons | 36.7(50 is the typical model of its size class)ARU454-H24A2/INVL-US2with ductless indoor unit ARU454-H24A2/INVL-US21 of 2 models qualify · AHRI 216980961 | 37.4(50 is the typical model of its size class) (higher)L01-CS-24K2V-20S-Owith ductless indoor unit L01-CS-24K2V-20S-WC-I3 of 6 models qualify · AHRI 218468367 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 47.6(50 is the typical model of its size class)L01-3Z-27K2V-20S-O2 of 4 models qualify · AHRI 218046437 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 24.7(50 is the typical model of its size class)L01-5Z-42K2V-20S-O1 of 1 models qualify · AHRI 218046439 |
All-around best
| Size and duct type | AURUSAll-around score, best model | LUORISEAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 67.7(50 is the typical model of its size class) (higher)ARU454-H12A2/INVL-US2with ductless indoor unit ARU454-H12A2/INVL-US27 of 8 models have all five ratings · AHRI 216980959 | 62.2(50 is the typical model of its size class)L01-2Z-18K2V-20S-O16 of 16 models have all five ratings · AHRI 218046436 |
| Non-ducted, 2 tons | 48.3(50 is the typical model of its size class) (higher)ARU454-H24A2/INVL-US2with ductless indoor unit ARU454-H24A2/INVL-US22 of 2 models have all five ratings · AHRI 216980961 | 35.1(50 is the typical model of its size class)L01-FC-24K2V-20S-Owith ductless indoor unit L01-FC-24K2V-20S-WC-I6 of 6 models have all five ratings · AHRI 218468373 |
| Non-ducted, 2.5–3 tons | 7.6(50 is the typical model of its size class)ARU32-H36A2/INVL-US2with ductless indoor unit ARU32-H36A2/INVL-US21 of 2 models have all five ratings · AHRI 216980958 | 38.7(50 is the typical model of its size class) (higher)L01-3Z-27K2V-20S-O4 of 4 models have all five ratings · AHRI 218046437 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 27.2(50 is the typical model of its size class)L01-5Z-42K2V-20S-O1 of 1 models have all five ratings · AHRI 218046439 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AURUS | LUORISE |
|---|---|---|
| COP at 5°F | beats 96% · 2.21ARU-H36A2-INVX-USNon-ducted, 2.5–3 tons | beats 63% · 2.00L01-2Z-18K2V-20S-ONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 49% · 74%ARU454-H24A2/INVL-US2Non-ducted, 2 tons | beats 69% · 86%L01-DU-09K2V-20S-ONon-ducted, up to 1.5 tons |
| HSPF2 | beats 64% · 10.0ARU454-H12A2/INVL-US2Non-ducted, up to 1.5 tons | beats 64% · 10.0L01-18K2V-20S-P-ONon-ducted, up to 1.5 tons |
| SEER2 | beats 79% · 23.0ARU454-H24A2/INVL-US2Non-ducted, 2 tons | beats 84% · 25.0L01-2Z-18K2V-20S-ONon-ducted, up to 1.5 tons |
| EER2 | beats 70% · 13.0ARU454-H12A2/INVL-US2Non-ducted, up to 1.5 tons | beats 56% · 12.5L01-09K2V-20S-P-ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 79% · 13,600 Btu/hARU454-H18A2/INVL-US2Non-ducted, up to 1.5 tons | beats 83% · 14,000 Btu/hL01-2Z-18K2V-20S-ONon-ducted, up to 1.5 tons |