Skip to content

AURUS vs LUORISE heat pumps

Measured against models of the same size and duct type, AURUS and LUORISE split the 6 ratings 3–3. AURUS has 12 outdoor models, LUORISE has 27 outdoor models. AURUS and LUORISE have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AURUS and LUORISE on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AURUS and LUORISE split the 6 ratings 3–3.
  • AURUS
  • LUORISE
  • Other ranked manufacturers
AURUSLUORISE

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAURUSLUORISE
Efficiency index32% (higher)median —30% (higher)median —
COP at 5°F41% (higher)median 1.8531% (higher)median 1.90
Capacity retention at 5°F21%median 70%30%median 71%
HSPF235%median 9.542%median 9.5
SEER231% (higher)median 17.028% (higher)median 20.0
EER227% (higher)median 9.521% (higher)median 9.5
Heating capacity at 5°F32%median 9,100 Btu/h36%median 12,000 Btu/h
Outdoor models1227
AHRI certifications1227

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAURUSLUORISE
CEE 2025 Tier 1 (Split ASHP)33.3%4 models48.1%13 models
CEE 2026 Tier 1 (Split ASHP)33.3%4 models48.1%13 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)33.3%4 models51.9%14 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate33.3%4 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 3 groups where both have models
  • AURUS
  • LUORISE
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAURUSLUORISE
Non-ducted, up to 1.5 tons8 · index 35%16 · index 33%
Non-ducted, 2 tons2 · index 31%6 · index 24%
Non-ducted, 2.5–3 tons2 · index 8%4 · index 26%
Non-ducted, 3.5–4.5 tonsNone1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAURUSCold-climate score, best modelLUORISECold-climate score, best model
Non-ducted, up to 1.5 tons59.5(50 is the typical model of its size class)ARU454-H12A2/INVL-US2with ductless indoor unit ARU454-H12A2/INVL-US23 of 8 models qualify · AHRI 21698095962.1(50 is the typical model of its size class) (higher)L01-2Z-18K2V-20S-O8 of 16 models qualify · AHRI 218046436
Non-ducted, 2 tons36.7(50 is the typical model of its size class)ARU454-H24A2/INVL-US2with ductless indoor unit ARU454-H24A2/INVL-US21 of 2 models qualify · AHRI 21698096137.4(50 is the typical model of its size class) (higher)L01-CS-24K2V-20S-Owith ductless indoor unit L01-CS-24K2V-20S-WC-I3 of 6 models qualify · AHRI 218468367
Non-ducted, 2.5–3 tonsNone on this board (0 of 2 models qualify)47.6(50 is the typical model of its size class)L01-3Z-27K2V-20S-O2 of 4 models qualify · AHRI 218046437
Non-ducted, 3.5–4.5 tonsNo models in this size class24.7(50 is the typical model of its size class)L01-5Z-42K2V-20S-O1 of 1 models qualify · AHRI 218046439

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAURUSAll-around score, best modelLUORISEAll-around score, best model
Non-ducted, up to 1.5 tons67.7(50 is the typical model of its size class) (higher)ARU454-H12A2/INVL-US2with ductless indoor unit ARU454-H12A2/INVL-US27 of 8 models have all five ratings · AHRI 21698095962.2(50 is the typical model of its size class)L01-2Z-18K2V-20S-O16 of 16 models have all five ratings · AHRI 218046436
Non-ducted, 2 tons48.3(50 is the typical model of its size class) (higher)ARU454-H24A2/INVL-US2with ductless indoor unit ARU454-H24A2/INVL-US22 of 2 models have all five ratings · AHRI 21698096135.1(50 is the typical model of its size class)L01-FC-24K2V-20S-Owith ductless indoor unit L01-FC-24K2V-20S-WC-I6 of 6 models have all five ratings · AHRI 218468373
Non-ducted, 2.5–3 tons7.6(50 is the typical model of its size class)ARU32-H36A2/INVL-US2with ductless indoor unit ARU32-H36A2/INVL-US21 of 2 models have all five ratings · AHRI 21698095838.7(50 is the typical model of its size class) (higher)L01-3Z-27K2V-20S-O4 of 4 models have all five ratings · AHRI 218046437
Non-ducted, 3.5–4.5 tonsNo models in this size class27.2(50 is the typical model of its size class)L01-5Z-42K2V-20S-O1 of 1 models have all five ratings · AHRI 218046439

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAURUSLUORISE
COP at 5°Fbeats 96% · 2.21ARU-H36A2-INVX-USNon-ducted, 2.5–3 tonsbeats 63% · 2.00L01-2Z-18K2V-20S-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 49% · 74%ARU454-H24A2/INVL-US2Non-ducted, 2 tonsbeats 69% · 86%L01-DU-09K2V-20S-ONon-ducted, up to 1.5 tons
HSPF2beats 64% · 10.0ARU454-H12A2/INVL-US2Non-ducted, up to 1.5 tonsbeats 64% · 10.0L01-18K2V-20S-P-ONon-ducted, up to 1.5 tons
SEER2beats 79% · 23.0ARU454-H24A2/INVL-US2Non-ducted, 2 tonsbeats 84% · 25.0L01-2Z-18K2V-20S-ONon-ducted, up to 1.5 tons
EER2beats 70% · 13.0ARU454-H12A2/INVL-US2Non-ducted, up to 1.5 tonsbeats 56% · 12.5L01-09K2V-20S-P-ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 79% · 13,600 Btu/hARU454-H18A2/INVL-US2Non-ducted, up to 1.5 tonsbeats 83% · 14,000 Btu/hL01-2Z-18K2V-20S-ONon-ducted, up to 1.5 tons

More comparisons