Skip to content

Antarctic Star vs AURUS heat pumps

Measured against models of the same size and duct type, Antarctic Star scores higher on 4 of the 6 ratings. Antarctic Star has 12 outdoor models, AURUS has 12 outdoor models. Antarctic Star and AURUS have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Antarctic Star and AURUS on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Antarctic Star scores higher on 4 of the 6 ratings.
  • Antarctic Star
  • AURUS
  • Other ranked manufacturers
Antarcti…AURUS

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAntarctic StarAURUS
Efficiency index36% (higher)median —33% (higher)median —
COP at 5°F62% (higher)median 2.0341% (higher)median 1.85
Capacity retention at 5°F30% (higher)median 68%23% (higher)median 70%
HSPF227%median 9.037%median 9.5
SEER238% (higher)median 19.832% (higher)median 17.0
EER225%median 10.629%median 9.5
Heating capacity at 5°F36% (higher)median 10,400 Btu/h33% (higher)median 9,100 Btu/h
Outdoor models1212
AHRI certifications1212

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAntarctic StarAURUS
CEE 2025 Tier 1 (Split ASHP)75%9 models33.3%4 models
CEE 2026 Tier 1 (Split ASHP)75%9 models33.3%4 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)50%6 models33.3%4 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models33.3%4 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 2 groups where both have models
  • Antarctic Star
  • AURUS
  • All models of the group
Non-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAntarctic StarAURUS
Non-ducted, up to 1.5 tons9 · index 39%8 · index 37%
Non-ducted, 2 tons3 · index 25%2 · index 33%
Non-ducted, 2.5 to 3 tonsNone2 · index 8%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAntarctic StarCold-climate score, best modelAURUSCold-climate score, best model
Non-ducted, up to 1.5 tons49.0(50 is the typical model of its size class)SE7203P-9K-ASZwith ductless indoor unit SE7203S-9K-ASZAlso listed as SE7203P-9K, SE7203PW-9K-ZAZ6 of 9 models qualify · AHRI 21808047061.2(50 is the typical model of its size class) (higher)ARU454-H12A2/INVL-US2with ductless indoor unit ARU454-H12A2/INVL-US23 of 8 models qualify · AHRI 216980959
Non-ducted, 2 tonsNone on this board (0 of 3 models qualify)38.7(50 is the typical model of its size class)ARU454-H24A2/INVL-US2with ductless indoor unit ARU454-H24A2/INVL-US21 of 2 models qualify · AHRI 216980961
Non-ducted, 2.5 to 3 tonsNo models in this size classNone on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAntarctic StarAll-around score, best modelAURUSAll-around score, best model
Non-ducted, up to 1.5 tons41.8(50 is the typical model of its size class)SE7203P-9K-ASZwith ductless indoor unit SE7203S-9K-ASZAlso listed as SE7203P-9K, SE7203PW-9K-ZAZ9 of 9 models have all five ratings · AHRI 21808047069.5(50 is the typical model of its size class) (higher)ARU454-H12A2/INVL-US2with ductless indoor unit ARU454-H12A2/INVL-US27 of 8 models have all five ratings · AHRI 216980959
Non-ducted, 2 tons25.2(50 is the typical model of its size class)SE7203P-24K-ASZwith ductless indoor unit SE7203S-24K-ASZAlso listed as SE7203P-24K, SE7203PW-24K-ZAZ3 of 3 models have all five ratings · AHRI 21808047150.9(50 is the typical model of its size class) (higher)ARU454-H24A2/INVL-US2with ductless indoor unit ARU454-H24A2/INVL-US22 of 2 models have all five ratings · AHRI 216980961
Non-ducted, 2.5 to 3 tonsNo models in this size class8.0(50 is the typical model of its size class)ARU32-H36A2/INVL-US2with ductless indoor unit ARU32-H36A2/INVL-US21 of 2 models have all five ratings · AHRI 216980958

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAntarctic StarAURUS
COP at 5°Fbeats 74% · 2.09SE7203P-18K-ASZAlso listed as SE7203S-18K, SE7203SW-18K-ZAZNon-ducted, up to 1.5 tonsbeats 95% · 2.21ARU-H36A2-INVX-USNon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 63% · 80%SE7203P-9K-ASZAlso listed as SE7203P-9K, SE7203PW-9K-ZAZNon-ducted, up to 1.5 tonsbeats 53% · 74%ARU454-H24A2/INVL-US2Non-ducted, 2 tons
HSPF2beats 30% · 9.0SE7203P-9K-ASZAlso listed as SE7203P-9K, SE7203PW-9K-ZAZNon-ducted, up to 1.5 tonsbeats 66% · 10.0ARU454-H12A2/INVL-US2Non-ducted, up to 1.5 tons
SEER2beats 59% · 22.0A7201P-12K-ELAlso listed as A7201PW-12K-EL, A7201PW-12K-ZAZNon-ducted, up to 1.5 tonsbeats 81% · 23.0ARU454-H24A2/INVL-US2Non-ducted, 2 tons
EER2beats 31% · 11.0SE7203P-18K-ASZAlso listed as SE7203S-18K, SE7203SW-18K-ZAZNon-ducted, up to 1.5 tonsbeats 73% · 13.0ARU454-H12A2/INVL-US2Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 74% · 12,600 Btu/hSE7203P-18K-ASZAlso listed as SE7203S-18K, SE7203SW-18K-ZAZNon-ducted, up to 1.5 tonsbeats 80% · 13,600 Btu/hARU454-H18A2/INVL-US2Non-ducted, up to 1.5 tons