Skip to content

Bladex vs YONAN: heat pump ratings compared

Against heat pumps of the same size and type, a typical Bladex model beats 57% and a typical YONAN model 55%. Bladex rates slightly higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

Bladex

57%

of similar heat pumps beaten by its typical model

Above average

56 models listed

YONAN

55%

of similar heat pumps beaten by its typical model

Above average

55 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FBladex: Beats 46%YONAN: Beats 55%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBladex: Beats 62%YONAN: Beats 37%
  • Winter-long heating efficiencyHSPF2Bladex: Beats 68%YONAN: Beats 61%
  • Summer-long cooling efficiencySEER2Bladex: Beats 60%YONAN: Beats 61%
  • Hot-day cooling efficiencyEER2Bladex: Beats 49%YONAN: Beats 51%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Bladex
    66%
    YONAN
    67%
  • Xcel CC

    Bladex
    57%
    YONAN
    35%
  • CEE Advanced

    Bladex
    0%
    YONAN
    0%
  • ENERGY STAR CC

    Bladex
    0%
    YONAN
    0%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

Bladex

  1. 1B40XS-36SPHP1BladexAlso listed as B40X-36SPHP1S3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 79.9Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.4 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    83.7score / 100Heating 80 · Cooling 88
  2. 2B30K-27SPHP1BladexAlso listed as B30K-27SPHP12.5 tons · 27,000 Btu/h · DuctedCold-climate pick, score 80.4Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    101% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.8 (EER2)
    Great
    81.9score / 100Heating 80 · Cooling 83
  3. 3B30I-28SPHP1BladexAlso listed as B30I-28SPHP12.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 66.8Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    74.7score / 100Heating 67 · Cooling 83

YONAN

  1. 1YSMO-30HRN1YONANAlso listed as YSMO-27HFN12.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 57.6Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.83 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    71.7score / 100Heating 58 · Cooling 86
  2. 2YSMO-36HRN1YONANAlso listed as YSMO-36HFN13 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 64% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    65% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.68 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    56.5score / 100Heating 44 · Cooling 69
  3. 3YOD-36HFN1with ducted air handler YTI-36HWFN1YONAN3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 55% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.91 (COP at 5°F)
    Good
    Winter efficiency
    8.8 (HSPF2)
    Good
    Cooling efficiency
    15.8 (SEER2)
    Below the middle
    Hot-day cooling
    8.8 (EER2)
    Below the middle
    37.7score / 100Heating 48 · Cooling 28

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter