BlueRidge vs Friedrich heat pumps

Measured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings. BlueRidge has 83 outdoor models, Friedrich has 117 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BlueRidge and Friedrich on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings.
  • BlueRidge
  • Friedrich
  • Other ranked manufacturers
BlueRidgeFriedrich

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBlueRidgeFriedrich
Efficiency index54% (higher)median — · 13th ranked44% (higher)median — · 26th ranked
COP at 5°F53%median 1.95 · 16th ranked57%median 2.10 · 9th ranked
Capacity retention at 5°F57% (higher)median 70% · 11th ranked44% (higher)median 58% · 21st ranked
HSPF256% (higher)median 9.1 · 10th ranked32% (higher)median 7.5 · 26th ranked
SEER250% (higher)median 18.9 · 13th ranked36% (higher)median 15.2 · 26th ranked
EER249% (higher)median 11.0 · 16th ranked39% (higher)median 10.6 · 26th ranked
Heating capacity at 5°F57% (higher)median 20,000 Btu/h · 9th ranked39% (higher)median 15,600 Btu/h · 25th ranked
Outdoor models83117
AHRI certifications1,2453,091

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBlueRidgeFriedrich
CEE 2025 Tier 1 (Split ASHP)61.4%51 models37.6%44 models
CEE 2026 Tier 1 (Split ASHP)57.8%48 models37.6%44 models
CEE Advanced Tier (Split ASHP)1.2%1 models1.7%2 models
Xcel Energy Colorado cold-climate ASHP (2025)45.8%38 models32.5%38 models
DOE Cold Climate Heat Pump Challenge1.2%1 models1.7%2 models
ENERGY STAR Cold Climate43.4%36 models24.8%29 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • BlueRidge
  • Friedrich
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBlueRidgeFriedrich
Ducted, up to 1.5 tons7 · index 52%21 · index 27%
Ducted, 2 tons5 · index 55%16 · index 45%
Ducted, 2.5 to 3 tons21 · index 59%22 · index 52%
Ducted, 3.5 to 4.5 tons12 · index 61%28 · index 47%
Ducted, 5 tons and up1 · index 63%7 · index —
Non-ducted, up to 1.5 tons25 · index 51%19 · index 56%
Non-ducted, 2 tons7 · index 55%6 · index 48%
Non-ducted, 2.5 to 3 tons18 · index 57%6 · index 26%
Non-ducted, 3.5 to 4.5 tons9 · index 42%1 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBlueRidgeCold-climate score, best modelFriedrichCold-climate score, best model
Ducted, up to 1.5 tons65.8(50 is the typical model of its size class) (higher)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models qualify · AHRI 20757138756.7(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A4 of 20 models qualify · AHRI 205048198
Ducted, 2 tons79.6(50 is the typical model of its size class) (higher)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models qualify · AHRI 20757139374.7(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU5 of 17 models qualify · AHRI 213829710
Ducted, 2.5 to 3 tons80.4(50 is the typical model of its size class)BMM27HH2C12 of 21 models qualify · AHRI 21236017980.5(50 is the typical model of its size class) (higher)FRP18AZ36AJVCwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU5 of 22 models qualify · AHRI 213829722
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)BMM48HHC4 of 12 models qualify · AHRI 20764130176.5(50 is the typical model of its size class) (higher)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR962V1005A21M47 of 28 models qualify · AHRI 214279028
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 7 models qualify)
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)BMY6HH27Cwith ductless indoor unit BMY6HH27WM14 of 25 models qualify · AHRI 20782669279.0(50 is the typical model of its size class)FPHFR09A3Awith ductless indoor unit FPHFC09A3B18 of 19 models qualify · AHRI 205048197
Non-ducted, 2 tons86.3(50 is the typical model of its size class) (higher)BMY24HH22Cwith ductless indoor unit BM24MFCC4 of 7 models qualify · AHRI 20757139473.4(50 is the typical model of its size class)FPHFR24A3Awith ductless indoor unit FPHFC24A3B5 of 6 models qualify · AHRI 205123805
Non-ducted, 2.5 to 3 tons87.5(50 is the typical model of its size class) (higher)BMM36HH2C10 of 18 models qualify · AHRI 21336337678.2(50 is the typical model of its size class)FPHFR36A3Awith ductless indoor unit FPHSC36A3B2 of 6 models qualify · AHRI 205150421
Non-ducted, 3.5 to 4.5 tons80.7(50 is the typical model of its size class) (higher)BMM48HHC6 of 9 models qualify · AHRI 20764130041.8(50 is the typical model of its size class)FPHMR42A3A1 of 1 models qualify · AHRI 205141513

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBlueRidgeAll-around score, best modelFriedrichAll-around score, best model
Ducted, up to 1.5 tons64.7(50 is the typical model of its size class) (higher)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models have all five ratings · AHRI 20757138758.1(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A16 of 20 models have all five ratings · AHRI 205048198
Ducted, 2 tons80.2(50 is the typical model of its size class)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models have all five ratings · AHRI 20757139383.5(50 is the typical model of its size class) (higher)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU12 of 17 models have all five ratings · AHRI 213829710
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class)BMM36HH2C18 of 20 models have all five ratings · AHRI 21336337786.0(50 is the typical model of its size class) (higher)FRP18AZ36AJVCwith ducted air handler FRHMVZ6021SEACA12 of 22 models have all five ratings · AHRI 213087287
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)BMM48HHC10 of 13 models have all five ratings · AHRI 20764130180.4(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR802V1005A21UH17 of 27 models have all five ratings · AHRI 214610153
Ducted, 5 tons and up62.8(50 is the typical model of its size class)BHP17L60P-**Awith indoor coil BC1P60C+TDR+TXV and furnace BG801UH090CE201 of 1 models have all five ratings · AHRI 21261986669.9(50 is the typical model of its size class) (higher)FWP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace FR97MV1005A21DH1 of 8 models have all five ratings · AHRI 213841738
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)BMY6HH27Cwith ductless indoor unit BMY6HH27WM25 of 25 models have all five ratings · AHRI 20782669285.6(50 is the typical model of its size class)MRH09Y3JAwith ductless indoor unit MWH09Y3JA18 of 19 models have all five ratings · AHRI 201763897
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)BMY24HH22Cwith ductless indoor unit BMY24HH22WM7 of 7 models have all five ratings · AHRI 20733918668.5(50 is the typical model of its size class)FPHMR24A3A6 of 6 models have all five ratings · AHRI 204101246
Non-ducted, 2.5 to 3 tons79.3(50 is the typical model of its size class) (higher)BMM27HH2C16 of 18 models have all five ratings · AHRI 21236017870.2(50 is the typical model of its size class)FPHMR36A3A6 of 6 models have all five ratings · AHRI 204101247
Non-ducted, 3.5 to 4.5 tons73.9(50 is the typical model of its size class) (higher)BMM48HHC9 of 9 models have all five ratings · AHRI 20764130044.4(50 is the typical model of its size class)FPHMR42A3A1 of 1 models have all five ratings · AHRI 205141512

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBlueRidgeFriedrich
COP at 5°Fbeats 96% · 2.77BHP17L48P-**ADucted, 3.5 to 4.5 tonsbeats 97% · 2.80WFPU17Z243CDucted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 144%BMKH0938/ONon-ducted, up to 1.5 tonsbeats 100% · 105%FRP18AZ48AJVCDucted, 3.5 to 4.5 tons
HSPF2beats 99% · 11.0BMY36HHUCDucted, 2.5 to 3 tonsbeats 83% · 9.5FPHFR36A3ADucted, 2.5 to 3 tons
SEER2beats 99% · 20.9BMM48HHCDucted, 3.5 to 4.5 tonsbeats 96% · 27.5MRH09Y3JANon-ducted, up to 1.5 tons
EER2beats 99% · 14.0BHP17L24P-**ADucted, 2 tonsbeats 93% · 15.5MRH09Y3JANon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 56,500 Btu/hBMY60HHUCNon-ducted, 3.5 to 4.5 tonsbeats 100% · 43,500 Btu/hFRP18AZ36AJVCDucted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BlueRidge vs Friedrich: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BlueRidge (median, middle 50%)
  • Friedrich (median, middle 50%)
Heating capacity, % of its 47°F maximum70%72%COP at maximum capacity1.922.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
BlueRidge: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F50100%100%100%100%100%
BlueRidge, 17°F5066%70%76%84%92%
BlueRidge, 5°F5054%57%70%77%83%
BlueRidge: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F502.642.813.063.213.45
BlueRidge, 17°F501.982.12.232.312.41
BlueRidge, 5°F501.81.831.9222.09
Friedrich: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F25100%100%100%100%100%
Friedrich, 17°F2565%72%79%83%93%
Friedrich, 5°F2550%59%72%75%77%
Friedrich: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F252.242.72.93.213.51
Friedrich, 17°F251.9222.282.42.72
Friedrich, 5°F251.821.8622.012.25

Source: NEEP ccASHP list · as of