Skip to content

BlueRidge vs Trane heat pumps

Measured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings. BlueRidge has 83 outdoor models, Trane has 309 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BlueRidge and Trane on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings.
  • BlueRidge
  • Trane
  • Other ranked manufacturers
BlueRidgeTrane

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBlueRidgeTrane
Efficiency index54% (higher)median — · 13th ranked53% (higher)median — · 17th ranked
COP at 5°F53%median 1.95 · 16th ranked70%median 2.18 · 4th ranked
Capacity retention at 5°F57% (higher)median 70% · 11th ranked44% (higher)median 63% · 22nd ranked
HSPF256% (higher)median 9.1 · 10th ranked35% (higher)median 7.8 · 25th ranked
SEER250% (higher)median 18.9 · 13th ranked37% (higher)median 15.2 · 25th ranked
EER249%median 11.0 · 16th ranked65%median 11.7 · 3rd ranked
Heating capacity at 5°F57% (higher)median 20,000 Btu/h · 9th ranked41% (higher)median 20,000 Btu/h · 22nd ranked
Outdoor models83309
AHRI certifications1,245103,959

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBlueRidgeTrane
CEE 2025 Tier 1 (Split ASHP)61.4%51 models31.4%97 models
CEE 2026 Tier 1 (Split ASHP)57.8%48 models26.2%81 models
CEE Advanced Tier (Split ASHP)1.2%1 models0.3%1 models
Xcel Energy Colorado cold-climate ASHP (2025)45.8%38 models22%68 models
DOE Cold Climate Heat Pump Challenge1.2%1 models0.3%1 models
ENERGY STAR Cold Climate43.4%36 models9.4%29 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • BlueRidge
  • Trane
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBlueRidgeTrane
Ducted, up to 1.5 tons7 · index 52%25 · index 35%
Ducted, 2 tons5 · index 55%53 · index 51%
Ducted, 2.5 to 3 tons21 · index 59%86 · index 54%
Ducted, 3.5 to 4.5 tons12 · index 61%108 · index 60%
Ducted, 5 tons and up1 · index 63%7 · index 47%
Non-ducted, up to 1.5 tons25 · index 51%23 · index 38%
Non-ducted, 2 tons7 · index 55%7 · index 55%
Non-ducted, 2.5 to 3 tons18 · index 57%10 · index 60%
Non-ducted, 3.5 to 4.5 tons9 · index 42%1 · index 19%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBlueRidgeCold-climate score, best modelTraneCold-climate score, best model
Ducted, up to 1.5 tons65.8(50 is the typical model of its size class) (higher)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models qualify · AHRI 20757138763.0(50 is the typical model of its size class)4A6H4018N1with ducted air handler AE(D,N,U)+CM30B34+TDR12 of 22 models qualify · AHRI 212361095
Ducted, 2 tons79.6(50 is the typical model of its size class) (higher)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models qualify · AHRI 20757139375.5(50 is the typical model of its size class)4TXD2036A10NU**with ducted air handler F,PE*G3493022 of 55 models qualify · AHRI 212396553
Ducted, 2.5 to 3 tons80.4(50 is the typical model of its size class)BMM27HH2C12 of 21 models qualify · AHRI 21236017982.2(50 is the typical model of its size class) (higher)4TWV0X36A1with indoor coil D(A,C,E)48C34+TDR and furnace S9V2C080U5PSC+RP32 of 87 models qualify · AHRI 215472282
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)BMM48HHC4 of 12 models qualify · AHRI 20764130184.2(50 is the typical model of its size class) (higher)4A6C7048A3with ducted air handler 4PX*DU60BS3+P0V0C000M50SCAlso listed as 4A6C7048A417 of 108 models qualify · AHRI 213867310
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 7 models qualify)
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)BMY6HH27Cwith ductless indoor unit BMY6HH27WM14 of 25 models qualify · AHRI 20782669280.8(50 is the typical model of its size class)4TXK3809B10NU**with ductless indoor unit 4MXW3809B10NU16 of 23 models qualify · AHRI 204340354
Non-ducted, 2 tons86.3(50 is the typical model of its size class) (higher)BMY24HH22Cwith ductless indoor unit BM24MFCC4 of 7 models qualify · AHRI 20757139477.3(50 is the typical model of its size class)4TXM2124A13N0**4 of 7 models qualify · AHRI 210435406
Non-ducted, 2.5 to 3 tons87.5(50 is the typical model of its size class) (higher)BMM36HH2C10 of 18 models qualify · AHRI 21336337674.7(50 is the typical model of its size class)4TXM2142A15N0**7 of 10 models qualify · AHRI 210435409
Non-ducted, 3.5 to 4.5 tons80.7(50 is the typical model of its size class) (higher)BMM48HHC6 of 9 models qualify · AHRI 20764130031.6(50 is the typical model of its size class)4TXM2336A15NU**1 of 1 models qualify · AHRI 206319651

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBlueRidgeAll-around score, best modelTraneAll-around score, best model
Ducted, up to 1.5 tons64.7(50 is the typical model of its size class) (higher)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models have all five ratings · AHRI 20757138753.0(50 is the typical model of its size class)4TWR5018N1with indoor coil D(A,C,E)30A34+TDR and furnace *UD2B060A9V3Also sold as American Standard 4A6H5018N120 of 23 models have all five ratings · AHRI 212367293
Ducted, 2 tons80.2(50 is the typical model of its size class) (higher)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models have all five ratings · AHRI 20757139377.1(50 is the typical model of its size class)4TWV8X24A1with indoor coil D(A,C,E)36C34+TDR and furnace S9V2B060U4PSB+RP42 of 52 models have all five ratings · AHRI 215472297
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class)BMM36HH2C18 of 20 models have all five ratings · AHRI 21336337785.1(50 is the typical model of its size class) (higher)4TWV0X36A1with indoor coil D(A,C,E)48C34+TDR and furnace S9V2C080U5PSC+RP69 of 83 models have all five ratings · AHRI 215472282
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class)BMM48HHC10 of 13 models have all five ratings · AHRI 20764130186.3(50 is the typical model of its size class) (higher)4A6C7048A3with ducted air handler 4PX*DU60BS3+P0V0C000M50SCAlso listed as 4A6C7048A490 of 114 models have all five ratings · AHRI 213867310
Ducted, 5 tons and up62.8(50 is the typical model of its size class)BHP17L60P-**Awith indoor coil BC1P60C+TDR+TXV and furnace BG801UH090CE201 of 1 models have all five ratings · AHRI 21261986681.2(50 is the typical model of its size class) (higher)4TWL9060A1with indoor coil TEM8B0C60V51+TDR and furnace N/AAlso sold as American Standard 4A6L9060A16 of 7 models have all five ratings · AHRI 207820927
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)BMY6HH27Cwith ductless indoor unit BMY6HH27WM25 of 25 models have all five ratings · AHRI 20782669289.1(50 is the typical model of its size class)4TXK3809B10NU**with ductless indoor unit 4MXW3809B10NU21 of 23 models have all five ratings · AHRI 204340354
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)BMY24HH22Cwith ductless indoor unit BMY24HH22WM7 of 7 models have all five ratings · AHRI 20733918672.4(50 is the typical model of its size class)4TXK2524A10N0**with ductless indoor unit 4MXW2524A10N05 of 7 models have all five ratings · AHRI 207629151
Non-ducted, 2.5 to 3 tons79.3(50 is the typical model of its size class) (higher)BMM27HH2C16 of 18 models have all five ratings · AHRI 21236017870.9(50 is the typical model of its size class)4TXM2142A15N0**7 of 10 models have all five ratings · AHRI 210435409
Non-ducted, 3.5 to 4.5 tons73.9(50 is the typical model of its size class) (higher)BMM48HHC9 of 9 models have all five ratings · AHRI 20764130018.7(50 is the typical model of its size class)4TXM2336A15NU**1 of 1 models have all five ratings · AHRI 206319651

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBlueRidgeTrane
COP at 5°Fbeats 96% · 2.77BHP17L48P-**ADucted, 3.5 to 4.5 tonsbeats 100% · 3.604A6C7048A3Also listed as 4A6C7048A4Ducted, 3.5 to 4.5 tons
Capacity retention at 5°Fbeats 99% · 144%BMKH0938/ONon-ducted, up to 1.5 tonsbeats 100% · 120%4A6H4042N1Ducted, 3.5 to 4.5 tons
HSPF2beats 99% · 11.0BMY36HHUCDucted, 2.5 to 3 tonsbeats 88% · 11.04TXK3809B10NU**Non-ducted, up to 1.5 tons
SEER2beats 99% · 20.9BMM48HHCDucted, 3.5 to 4.5 tonsbeats 99% · 19.04TWL9060A1Also sold as American Standard 4A6L9060A1Ducted, 5 tons and up
EER2beats 99% · 14.0BHP17L24P-**ADucted, 2 tonsbeats 99% · 16.64TXK3809B10NU**Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 56,500 Btu/hBMY60HHUCNon-ducted, 3.5 to 4.5 tonsbeats 100% · 34,000 Btu/hE4HL5018A1000ADucted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BlueRidge vs Trane: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BlueRidge (median, middle 50%)
  • Trane (median, middle 50%)
Heating capacity, % of its 47°F maximum70%71%COP at maximum capacity1.921.84

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
BlueRidge: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F50100%100%100%100%100%
BlueRidge, 17°F5066%70%76%84%92%
BlueRidge, 5°F5054%57%70%77%83%
BlueRidge: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F502.642.813.063.213.45
BlueRidge, 17°F501.982.12.232.312.41
BlueRidge, 5°F501.81.831.9222.09
Trane: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Trane, 47°F22100%100%100%100%100%
Trane, 17°F2272%73%83%88%99%
Trane, 5°F2257%70%71%75%83%
Trane: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Trane, 47°F222.93.033.183.223.39
Trane, 17°F221.912.042.32.42.49
Trane, 5°F221.81.81.841.942.2

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy