Skip to content

BlueRidge vs Trane heat pumps

Measured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings. BlueRidge has 194 outdoor models, Trane has 370 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BlueRidge and Trane on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings.
  • BlueRidge
  • Trane
  • Other ranked manufacturers
BlueRidgeTrane

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBlueRidgeTrane
Efficiency index57% (higher)median — · 10th ranked50% (higher)median — · 19th ranked
COP at 5°F57%median 2.00 · 13th ranked69%median 2.27 · 1st ranked
Capacity retention at 5°F55% (higher)median 74% · 12th ranked43% (higher)median 65% · 25th ranked
HSPF260% (higher)median 9.5 · 9th ranked35% (higher)median 7.5 · 27th ranked
SEER258% (higher)median 19.0 · 9th ranked40% (higher)median 15.5 · 26th ranked
EER254%median 11.9 · 15th ranked67%median 11.7 · 3rd ranked
Heating capacity at 5°F57% (higher)median 19,000 Btu/h · 11th ranked44% (higher)median 21,400 Btu/h · 25th ranked
Outdoor models194370
AHRI certifications1,70093,740

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBlueRidgeTrane
CEE 2025 Tier 1 (Split ASHP)75.3%146 models38.6%143 models
CEE 2026 Tier 1 (Split ASHP)73.2%142 models36.2%134 models
CEE Advanced Tier (Split ASHP)3.6%7 models2.4%9 models
Xcel Energy Colorado cold-climate ASHP (2025)68%132 models25.4%94 models
DOE Cold Climate Heat Pump Challenge3.6%7 models2.4%9 models
ENERGY STAR Cold Climate64.4%125 models16.8%62 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • BlueRidge
  • Trane
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBlueRidgeTrane
Ducted, up to 1.5 tons29 · index 70%19 · index 49%
Ducted, 2 tons21 · index 59%40 · index 42%
Ducted, 2.5 to 3 tons38 · index 56%108 · index 50%
Ducted, 3.5 to 4.5 tons36 · index 60%133 · index 53%
Ducted, 5 tons and up5 · index 64%46 · index 50%
Non-ducted, up to 1.5 tons74 · index 55%15 · index 55%
Non-ducted, 2 tons17 · index 51%4 · index 44%
Non-ducted, 2.5 to 3 tons26 · index 51%7 · index 56%
Non-ducted, 3.5 to 4.5 tons20 · index 47%3 · index 63%
Non-ducted, 5 tons and up2 · index 59%2 · index 68%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBlueRidgeCold-climate score, best modelTraneCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD24 of 29 models qualify · AHRI 21585393892.7(50 is the typical model of its size class)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB6 of 21 models qualify · AHRI 216794262
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)BMS2421HHYCwith ducted air handler BMC24HCDAlso listed as BXS5A24UC018 of 22 models qualify · AHRI 21585394577.9(50 is the typical model of its size class)5A6H7024A1with ducted air handler CM24D3J+TDR13 of 38 models qualify · AHRI 217155223
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class)BMS36HHUYCwith ducted air handler BMS36HCDAlso listed as BXL2A36UC022 of 37 models qualify · AHRI 21585396195.1(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5TAMXD06AV41Also sold as American Standard 5A5V0X36A126 of 108 models qualify · AHRI 218868829
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class)BNG3Z60UCMwith ducted air handler BNGFZ60DH0Also listed as BNG3Z60UCN29 of 36 models qualify · AHRI 21799260792.8(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP39 of 133 models qualify · AHRI 216794596
Ducted, 5 tons and upNone on this board (0 of 5 models qualify)81.8(50 is the typical model of its size class)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA2 of 46 models qualify · AHRI 218451025
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC053 of 74 models qualify · AHRI 21585390170.1(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models qualify · AHRI 218067082
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)BMS2421HHYCwith ductless indoor unit BMC24CCAlso listed as BXS5A24UC014 of 17 models qualify · AHRI 21585393339.6(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models qualify · AHRI 215385437
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)BMS36HHUYCwith ductless indoor unit BMS36FCCAlso listed as BXL2A36UC021 of 26 models qualify · AHRI 21585396474.4(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA5 of 7 models qualify · AHRI 218451026
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC017 of 20 models qualify · AHRI 21585399067.5(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models qualify · AHRI 218451027
Non-ducted, 5 tons and upNone on this board (0 of 2 models qualify)64.2(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models qualify · AHRI 218451028

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBlueRidgeAll-around score, best modelTraneAll-around score, best model
Ducted, up to 1.5 tons95.1(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD29 of 29 models have all five ratings · AHRI 21585393885.1(50 is the typical model of its size class)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRP18 of 18 models have all five ratings · AHRI 216794699
Ducted, 2 tons78.9(50 is the typical model of its size class)BMS2423YCwith ducted air handler BMC24HCDAlso listed as BXS3A24SC021 of 21 models have all five ratings · AHRI 21585392481.5(50 is the typical model of its size class) (higher)5A6V0X24A1with indoor coil 5PX*BD06AS3 and furnace S9V2B060D3VSB+VCKIT28 of 28 models have all five ratings · AHRI 218036320
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC037 of 37 models have all five ratings · AHRI 21585398695.7(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5PX*D010AS3+P0V0D000M50SD+LRPAlso sold as American Standard 5A5V0X36A175 of 111 models have all five ratings · AHRI 218868823
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)BMMZ48CAlso listed as BXM1A48SC037 of 37 models have all five ratings · AHRI 21585397789.2(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP107 of 143 models have all five ratings · AHRI 216794476
Ducted, 5 tons and up67.2(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 21637190974.8(50 is the typical model of its size class) (higher)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA9 of 46 models have all five ratings · AHRI 218451025
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC072 of 74 models have all five ratings · AHRI 21585390173.9(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models have all five ratings · AHRI 218067082
Non-ducted, 2 tons87.8(50 is the typical model of its size class) (higher)BMS2423YCwith ductless indoor unit BMC24HHYWAlso listed as BXS3A24SC016 of 17 models have all five ratings · AHRI 21585390051.4(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models have all five ratings · AHRI 215385437
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)BMMZ36HHCAlso listed as BXM3A36UC026 of 26 models have all five ratings · AHRI 21585398576.7(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA7 of 7 models have all five ratings · AHRI 218451026
Non-ducted, 3.5 to 4.5 tons75.4(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC020 of 20 models have all five ratings · AHRI 21585398873.8(50 is the typical model of its size class)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models have all five ratings · AHRI 218451027
Non-ducted, 5 tons and up59.0(50 is the typical model of its size class)BMMZ60CAlso listed as BXM1A60SC02 of 2 models have all five ratings · AHRI 21585399468.0(50 is the typical model of its size class) (higher)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models have all five ratings · AHRI 218451028

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBlueRidgeTrane
COP at 5°Fbeats 99% · 2.51BMS1226YCAlso listed as BXS3A12SC0Non-ducted, up to 1.5 tonsbeats 100% · 3.205TWR4036A1Ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 100% · 150%BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 136%5A6H7036A1Ducted, 2.5 to 3 tons
HSPF2beats 100% · 15.6BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 13.53TXK2224AF00HAAAlso listed as 3TXK2236AF00HAA, 3TVHS036SF000AADucted, 2.5 to 3 tons
SEER2beats 100% · 35.0BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 99% · 21.65TWV0X36A1Also sold as American Standard 5A6V0X36A1Ducted, 2.5 to 3 tons
EER2beats 99% · 18.0BMS626HHYCAlso listed as BXS5A06UC0Non-ducted, up to 1.5 tonsbeats 99% · 13.55TCV0X36A1Also sold as American Standard 5A5V0X36A1Ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hBMS1826SHYCAlso listed as BXS6A18UC0Non-ducted, up to 1.5 tonsbeats 100% · 27,200 Btu/h5TWV0X24A1Ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BlueRidge vs Trane: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BlueRidge (median, middle 50%)
  • Trane (median, middle 50%)
Heating capacity, % of its 47°F maximum66%70%COP at maximum capacity2.002.10

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
BlueRidge: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F175100%100%100%100%100%
BlueRidge, 17°F17564%68%74%82%88%
BlueRidge, 5°F17557%60%66%78%83%
BlueRidge: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F1752.883.073.233.473.59
BlueRidge, 17°F1752.032.192.332.412.61
BlueRidge, 5°F1751.831.9622.142.31
Trane: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Trane, 47°F52100%100%100%100%100%
Trane, 17°F5271%73%85%90%93%
Trane, 5°F5257%64%70%73%76%
Trane: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Trane, 47°F522.472.923.143.664
Trane, 17°F522.142.22.42.52.6
Trane, 5°F521.81.962.12.22.22

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy