Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
BlueRidge vs York heat pumps
Measured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings. BlueRidge has 83 outdoor models, York has 179 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- BlueRidge
- York
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | BlueRidge | York |
|---|---|---|
| Efficiency index | 54% (higher)median — · 17th ranked | 51% (higher)median — · 21st ranked |
| COP at 5°F | 51%median 1.95 · 16th ranked | 69%median 2.20 · 5th ranked |
| Capacity retention at 5°F | 57% (higher)median 70% · 11th ranked | 50% (higher)median 69% · 18th ranked |
| HSPF2 | 55% (higher)median 9.1 · 10th ranked | 37% (higher)median 7.7 · 23rd ranked |
| SEER2 | 50% (higher)median 18.9 · 14th ranked | 38% (higher)median 15.2 · 24th ranked |
| EER2 | 49%median 11.0 · 16th ranked | 57%median 11.0 · 9th ranked |
| Heating capacity at 5°F | 57% (higher)median 20,000 Btu/h · 9th ranked | 49% (higher)median 24,200 Btu/h · 17th ranked |
| Outdoor models | 83 | 179 |
| AHRI certifications | 1,245 | 65,299 |
Share of models meeting each standard
| Standard | BlueRidge | York |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 61.4%51 models | 26.3%47 models |
| CEE 2026 Tier 1 (Split ASHP) | 57.8%48 models | 26.3%47 models |
| CEE Advanced Tier (Split ASHP) | 2.4%2 models | 0.6%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 45.8%38 models | 25.7%46 models |
| DOE Cold Climate Heat Pump Challenge | 2.4%2 models | 0.6%1 models |
| ENERGY STAR Cold Climate | 47%39 models | 2.2%4 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- BlueRidge
- York
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | BlueRidge | York |
|---|---|---|
| Ducted, up to 1.5 tons | 7 · index 52% | 8 · index 42% |
| Ducted, 2 tons | 5 · index 54% | 17 · index 47% |
| Ducted, 2.5–3 tons | 21 · index 59% | 53 · index 51% |
| Ducted, 3.5–4.5 tons | 12 · index 61% | 71 · index 60% |
| Ducted, 5 tons and up | 1 · index 63% | 19 · index 50% |
| Non-ducted, up to 1.5 tons | 25 · index 50% | 9 · index 25% |
| Non-ducted, 2 tons | 7 · index 54% | 2 · index 41% |
| Non-ducted, 2.5–3 tons | 18 · index 56% | 6 · index 54% |
| Non-ducted, 3.5–4.5 tons | 9 · index 42% | 5 · index 46% |
| Non-ducted, 5 tons and up | None | 2 · index 46% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BlueRidgeCold-climate score, best model | YorkCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 65.4(50 is the typical model of its size class) (higher)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models qualify · AHRI 207571387 | 59.7(50 is the typical model of its size class)THF2B18S21with ducted air handler AE(D,N,U)+CM24D24+TDR7 of 8 models qualify · AHRI 214606310 |
| Ducted, 2 tons | 79.4(50 is the typical model of its size class) (higher)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models qualify · AHRI 207571393 | 60.6(50 is the typical model of its size class)THE2B24T21with ducted air handler AX242BTA10 of 16 models qualify · AHRI 211634285 |
| Ducted, 2.5–3 tons | 80.4(50 is the typical model of its size class)BMM27HH2C12 of 21 models qualify · AHRI 212360179 | 83.8(50 is the typical model of its size class) (higher)HMH72B341with indoor coil CM36B36+TDR and furnace TM9V120D20MP1222 of 53 models qualify · AHRI 211628039 |
| Ducted, 3.5–4.5 tons | 74.9(50 is the typical model of its size class)BMM48HHC4 of 12 models qualify · AHRI 207641301 | 77.7(50 is the typical model of its size class) (higher)RHP15048B21with ducted air handler L(E,G)M60A4Also sold as Champion Heating and Cooling THF2B48T2124 of 72 models qualify · AHRI 213612208 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 70.2(50 is the typical model of its size class)YMKE60BNJMFMO-X1 of 19 models qualify · AHRI 205739196 |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class) (higher)BMY6HH27Cwith ductless indoor unit BMY6HH27WM14 of 25 models qualify · AHRI 207826692 | 64.2(50 is the typical model of its size class)DHS18CMB22S5 of 9 models qualify · AHRI 207616532 |
| Non-ducted, 2 tons | 85.4(50 is the typical model of its size class) (higher)BMY24HH22Cwith ductless indoor unit BM24MFCC4 of 7 models qualify · AHRI 207571394 | 66.1(50 is the typical model of its size class)DHS24CMB22S1 of 2 models qualify · AHRI 207616534 |
| Non-ducted, 2.5–3 tons | 87.0(50 is the typical model of its size class) (higher)BMM36HH2C10 of 18 models qualify · AHRI 213363376 | 60.8(50 is the typical model of its size class)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models qualify · AHRI 203994967 |
| Non-ducted, 3.5–4.5 tons | 80.5(50 is the typical model of its size class) (higher)BMM48HHC6 of 9 models qualify · AHRI 207641300 | 31.6(50 is the typical model of its size class)DHS42CMB22S1 of 5 models qualify · AHRI 207616540 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | BlueRidgeAll-around score, best model | YorkAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 64.5(50 is the typical model of its size class) (higher)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models have all five ratings · AHRI 207571387 | 57.1(50 is the typical model of its size class)YH2F18SB21with ducted air handler AE*S+CM24C24+TDR7 of 7 models have all five ratings · AHRI 216437405 |
| Ducted, 2 tons | 80.1(50 is the typical model of its size class) (higher)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models have all five ratings · AHRI 207571393 | 77.1(50 is the typical model of its size class)YMSJYH024BAAND-1with ducted air handler YMSJXH024BAAN--517 of 17 models have all five ratings · AHRI 217734524 |
| Ducted, 2.5–3 tons | 83.7(50 is the typical model of its size class) (higher)BMM36HH2C18 of 20 models have all five ratings · AHRI 213363377 | 76.1(50 is the typical model of its size class)YMSJYH048BAAND-1with ducted air handler YMSJXH048BAAN--534 of 51 models have all five ratings · AHRI 217734526 |
| Ducted, 3.5–4.5 tons | 82.0(50 is the typical model of its size class)BMM48HHC10 of 13 models have all five ratings · AHRI 207641301 | 83.7(50 is the typical model of its size class) (higher)YZV48B21with indoor coil XAMC48HE3N1+CC and furnace TM9V100C16MP1248 of 73 models have all five ratings · AHRI 211207031 |
| Ducted, 5 tons and up | 62.6(50 is the typical model of its size class)BHP17L60P-**Awith indoor coil BC1P60C+TDR+TXV and furnace BG801UH090CE201 of 1 models have all five ratings · AHRI 212619866 | 75.1(50 is the typical model of its size class) (higher)YMKE60BNJMFMO-X12 of 20 models have all five ratings · AHRI 205739196 |
| Non-ducted, up to 1.5 tons | 92.0(50 is the typical model of its size class) (higher)BMY6HH27Cwith ductless indoor unit BMY6HH27WM25 of 25 models have all five ratings · AHRI 207826692 | 50.6(50 is the typical model of its size class)DHS18CMB22S9 of 9 models have all five ratings · AHRI 207616532 |
| Non-ducted, 2 tons | 84.3(50 is the typical model of its size class) (higher)BMY24HH22Cwith ductless indoor unit BMY24HH22WM7 of 7 models have all five ratings · AHRI 207339186 | 55.4(50 is the typical model of its size class)DHS24CMB22S2 of 2 models have all five ratings · AHRI 207616534 |
| Non-ducted, 2.5–3 tons | 78.8(50 is the typical model of its size class) (higher)BMM27HH2C16 of 18 models have all five ratings · AHRI 212360178 | 74.6(50 is the typical model of its size class)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models have all five ratings · AHRI 203994967 |
| Non-ducted, 3.5–4.5 tons | 73.8(50 is the typical model of its size class) (higher)BMM48HHC9 of 9 models have all five ratings · AHRI 207641300 | 67.0(50 is the typical model of its size class)YVAHP048B21S*Also sold as Coleman CVAHP048B21S3 of 5 models have all five ratings · AHRI 203994968 |
| Non-ducted, 5 tons and up | No models in this size class | 68.5(50 is the typical model of its size class)YVAHP060B21S*2 of 2 models have all five ratings · AHRI 203994964 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | BlueRidge | York |
|---|---|---|
| COP at 5°F | beats 96% · 2.77BHP17L48P-**ADucted, 3.5–4.5 tons | beats 100% · 3.44THE2B42T21Ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 99% · 144%BMKH0938/ONon-ducted, up to 1.5 tons | beats 100% · 149%THE2B18S21Ducted, up to 1.5 tons |
| HSPF2 | beats 99% · 11.0BMY36HHUCDucted, 2.5–3 tons | beats 98% · 10.0YVAHP048B21S*Also sold as Coleman CVAHP048B21SDucted, 3.5–4.5 tons |
| SEER2 | beats 99% · 20.9BMM48HHCDucted, 3.5–4.5 tons | beats 96% · 18.0YMKE60BNJMFMO-XDucted, 5 tons and up |
| EER2 | beats 99% · 14.0BHP17L24P-**ADucted, 2 tons | beats 100% · 16.7YVAHP048B21S*Also sold as Coleman CVAHP048B21SNon-ducted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 99% · 56,500 Btu/hBMY60HHUCNon-ducted, 3.5–4.5 tons | beats 99% · 21,800 Btu/hDHS18CMB22SNon-ducted, up to 1.5 tons |