Skip to content

BlueRidge vs York heat pumps

Measured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings. BlueRidge has 194 outdoor models, York has 239 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BlueRidge and York on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings.
  • BlueRidge
  • York
  • Other ranked manufacturers
BlueRidgeYork

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBlueRidgeYork
Efficiency index57% (higher)median — · 10th ranked54% (higher)median — · 12th ranked
COP at 5°F57%median 2.00 · 13th ranked67%median 2.13 · 2nd ranked
Capacity retention at 5°F55% (higher)median 74% · 12th ranked53% (higher)median 70% · 14th ranked
HSPF260% (higher)median 9.5 · 9th ranked45% (higher)median 8.1 · 20th ranked
SEER258% (higher)median 19.0 · 9th ranked40% (higher)median 16.0 · 25th ranked
EER254%median 11.9 · 15th ranked58%median 11.7 · 11th ranked
Heating capacity at 5°F57% (higher)median 19,000 Btu/h · 11th ranked55% (higher)median 20,000 Btu/h · 14th ranked
Outdoor models194239
AHRI certifications1,700109,938

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBlueRidgeYork
CEE 2025 Tier 1 (Split ASHP)75.3%146 models54.4%130 models
CEE 2026 Tier 1 (Split ASHP)73.2%142 models54.4%130 models
CEE Advanced Tier (Split ASHP)3.6%7 models7.5%18 models
Xcel Energy Colorado cold-climate ASHP (2025)68%132 models41.4%99 models
DOE Cold Climate Heat Pump Challenge3.6%7 models7.5%18 models
ENERGY STAR Cold Climate64.4%125 models38.1%91 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • BlueRidge
  • York
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBlueRidgeYork
Ducted, up to 1.5 tons29 · index 70%24 · index 56%
Ducted, 2 tons21 · index 59%21 · index 48%
Ducted, 2.5 to 3 tons38 · index 56%58 · index 50%
Ducted, 3.5 to 4.5 tons36 · index 60%70 · index 50%
Ducted, 5 tons and up5 · index 64%13 · index 43%
Non-ducted, up to 1.5 tons74 · index 55%49 · index 61%
Non-ducted, 2 tons17 · index 51%17 · index 63%
Non-ducted, 2.5 to 3 tons26 · index 51%16 · index 52%
Non-ducted, 3.5 to 4.5 tons20 · index 47%6 · index 56%
Non-ducted, 5 tons and up2 · index 59%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBlueRidgeCold-climate score, best modelYorkCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD24 of 29 models qualify · AHRI 21585393880.8(50 is the typical model of its size class)YPAS18BLFASDQ1with ducted air handler YPPIMB18UFA1DQ11 of 22 models qualify · AHRI 218694255
Ducted, 2 tons85.8(50 is the typical model of its size class)BMS2421HHYCwith ducted air handler BMC24HCDAlso listed as BXS5A24UC018 of 22 models qualify · AHRI 21585394590.1(50 is the typical model of its size class) (higher)HH824E2S11with ducted air handler D(A,C,E)36A4K+JMC12B2SN1+TDR12 of 23 models qualify · AHRI 218026253
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class)BMS36HHUYCwith ducted air handler BMS36HCDAlso listed as BXL2A36UC022 of 37 models qualify · AHRI 21585396192.1(50 is the typical model of its size class) (higher)HH836E2S11with indoor coil D(A,C,E)36A4K+TDR and furnace Z9ET080C16SMPS122 of 60 models qualify · AHRI 218350129
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class)BNG3Z60UCMwith ducted air handler BNGFZ60DH0Also listed as BNG3Z60UCN29 of 36 models qualify · AHRI 21799260790.1(50 is the typical model of its size class) (higher)HH860E2S11with ducted air handler DM59A4K+JMC20D2SN1+TDR19 of 68 models qualify · AHRI 218026269
Ducted, 5 tons and upNone on this board (0 of 5 models qualify)64.2(50 is the typical model of its size class)PH9E60N00D212 of 13 models qualify · AHRI 218450295
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC053 of 74 models qualify · AHRI 21585390192.4(50 is the typical model of its size class)YPAS18BLFASDQ1with ductless indoor unit YPCIB18UFA1DQ42 of 49 models qualify · AHRI 218694256
Non-ducted, 2 tons90.1(50 is the typical model of its size class)BMS2421HHYCwith ductless indoor unit BMC24CCAlso listed as BXS5A24UC014 of 17 models qualify · AHRI 21585393397.0(50 is the typical model of its size class) (higher)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ14 of 17 models qualify · AHRI 218694257
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class)BMS36HHUYCwith ductless indoor unit BMS36FCCAlso listed as BXL2A36UC021 of 26 models qualify · AHRI 21585396497.3(50 is the typical model of its size class) (higher)YPAS30BLFASDQ1with ductless indoor unit YPCIB30UFA1DQ12 of 16 models qualify · AHRI 218694248
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC017 of 20 models qualify · AHRI 21585399059.5(50 is the typical model of its size class)YPAS48BUFASDQ1with ductless indoor unit YPPFCB48UFA1DQ4 of 6 models qualify · AHRI 218696687
Non-ducted, 5 tons and upNone on this board (0 of 2 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBlueRidgeAll-around score, best modelYorkAll-around score, best model
Ducted, up to 1.5 tons95.1(50 is the typical model of its size class) (higher)BMS626HHYCwith ducted air handler BMC6LCD29 of 29 models have all five ratings · AHRI 21585393880.7(50 is the typical model of its size class)YPAS12BLFASDQ1with ducted air handler YPPIMB12UFA1DQ23 of 23 models have all five ratings · AHRI 218694251
Ducted, 2 tons78.9(50 is the typical model of its size class) (higher)BMS2423YCwith ducted air handler BMC24HCDAlso listed as BXS3A24SC021 of 21 models have all five ratings · AHRI 21585392477.5(50 is the typical model of its size class)HH824E2S11with ducted air handler D(A,C,E)36A4K+JME08B2SN1+TDR25 of 25 models have all five ratings · AHRI 218026254
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC037 of 37 models have all five ratings · AHRI 21585398691.3(50 is the typical model of its size class) (higher)YPAS30BUFASDQ1with ducted air handler YPPIMB30UFA1DQ39 of 55 models have all five ratings · AHRI 218694240
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)BMMZ48CAlso listed as BXM1A48SC037 of 37 models have all five ratings · AHRI 21585397786.0(50 is the typical model of its size class) (higher)HH860E2S11with ducted air handler D(A,C,E)60B3K+JMC20D2SN1+TDR45 of 69 models have all five ratings · AHRI 218014963
Ducted, 5 tons and up67.2(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 21637190970.5(50 is the typical model of its size class) (higher)PH9E60N00D216 of 14 models have all five ratings · AHRI 218450295
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC072 of 74 models have all five ratings · AHRI 21585390190.1(50 is the typical model of its size class)YRACXJ12WHAAwith ductless indoor unit YRAKXJ12PHAA49 of 49 models have all five ratings · AHRI 218037193
Non-ducted, 2 tons87.8(50 is the typical model of its size class) (higher)BMS2423YCwith ductless indoor unit BMC24HHYWAlso listed as BXS3A24SC016 of 17 models have all five ratings · AHRI 21585390085.7(50 is the typical model of its size class)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ17 of 17 models have all five ratings · AHRI 218694257
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC026 of 26 models have all five ratings · AHRI 21585398585.2(50 is the typical model of its size class) (higher)YPAS30BUFASDQ1with ductless indoor unit YPCIB30UFA1DQ16 of 16 models have all five ratings · AHRI 218694244
Non-ducted, 3.5 to 4.5 tons75.4(50 is the typical model of its size class) (higher)BMMZ48HHCAlso listed as BXM3A48UC020 of 20 models have all five ratings · AHRI 21585398867.8(50 is the typical model of its size class)YRAMX42N5HBA6 of 6 models have all five ratings · AHRI 218080472
Non-ducted, 5 tons and up59.0(50 is the typical model of its size class)BMMZ60CAlso listed as BXM1A60SC02 of 2 models have all five ratings · AHRI 215853994No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBlueRidgeYork
COP at 5°Fbeats 99% · 2.51BMS1226YCAlso listed as BXS3A12SC0Non-ducted, up to 1.5 tonsbeats 100% · 3.55UPC24CN23STG1Ducted, 2 tons
Capacity retention at 5°Fbeats 100% · 150%BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 147%YRACXJ09WHAANon-ducted, up to 1.5 tons
HSPF2beats 100% · 15.6BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 12.0YPAS30BUFASDQ1Non-ducted, 2.5 to 3 tons
SEER2beats 100% · 35.0BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 22.0YH960E2C11Also sold as Coleman XH960E2C11Ducted, 3.5 to 4.5 tons
EER2beats 99% · 18.0BMS626HHYCAlso listed as BXS5A06UC0Non-ducted, up to 1.5 tonsbeats 99% · 14.4YPAS36BLFASDQ1Non-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hBMS1826SHYCAlso listed as BXS6A18UC0Non-ducted, up to 1.5 tonsbeats 100% · 23,000 Btu/hYRACXJ18WHAAAlso listed as YRACXJ18WHBANon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BlueRidge vs York: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BlueRidge (median, middle 50%)
  • York (median, middle 50%)
Heating capacity, % of its 47°F maximum66%72%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
BlueRidge: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F175100%100%100%100%100%
BlueRidge, 17°F17564%68%74%82%88%
BlueRidge, 5°F17557%60%66%78%83%
BlueRidge: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F1752.883.073.233.473.59
BlueRidge, 17°F1752.032.192.332.412.61
BlueRidge, 5°F1751.831.9622.142.31
York: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
York, 47°F50100%100%100%100%100%
York, 17°F5066%73%79%88%97%
York, 5°F5058%62%72%80%84%
York: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
York, 47°F502.72.963.233.43.62
York, 17°F502.152.22.32.42.51
York, 5°F501.81.8822.12.2

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter