Skip to content

BOREAL vs DUOHOME heat pumps

Measured against models of the same size and duct type, DUOHOME scores higher on 4 of the 6 ratings. BOREAL has 28 outdoor models, DUOHOME has 22 outdoor models. BOREAL and DUOHOME have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BOREAL and DUOHOME on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, DUOHOME scores higher on 4 of the 6 ratings.
  • BOREAL
  • DUOHOME
  • Other ranked manufacturers
BOREALDUOHOME

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBOREALDUOHOME
Efficiency index44%median —53%median —
COP at 5°F33%median 1.8152%median 1.99
Capacity retention at 5°F62% (higher)median 74%39% (higher)median 66%
HSPF237%median 8.561%median 9.3
SEER244%median 19.857%median 20.0
EER242%median 11.344%median 10.7
Heating capacity at 5°F56% (higher)median 13,300 Btu/h44% (higher)median 14,800 Btu/h
Outdoor models2822
AHRI certifications4837

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBOREALDUOHOME
CEE 2025 Tier 1 (Split ASHP)71.4%20 models59.1%13 models
CEE 2026 Tier 1 (Split ASHP)67.9%19 models50%11 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)67.9%19 models27.3%6 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate39.3%11 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • BOREAL
  • DUOHOME
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBOREALDUOHOME
Ducted, up to 1.5 tons2 · index 44%2 · index 69%
Ducted, 2 tons2 · index 53%1 · index 84%
Ducted, 2.5 to 3 tons3 · index 52%4 · index 55%
Ducted, 3.5 to 4.5 tons1 · index 63%4 · index 53%
Ducted, 5 tons and upNone1 · index 54%
Non-ducted, up to 1.5 tons15 · index 33%9 · index 50%
Non-ducted, 2 tons3 · index 47%2 · index 48%
Non-ducted, 2.5 to 3 tons8 · index 57%5 · index 50%
Non-ducted, 3.5 to 4.5 tonsNone3 · index 43%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBOREALCold-climate score, best modelDUOHOMECold-climate score, best model
Ducted, up to 1.5 tons37.6(50 is the typical model of its size class)KULA12HPJ1OBwith ducted air handler BDUCT12HPJ1DA2 of 2 models qualify · AHRI 21746405552.6(50 is the typical model of its size class) (higher)D2OA-18HFN1-M1 of 2 models qualify · AHRI 211911389
Ducted, 2 tons50.3(50 is the typical model of its size class)MBRS24HPJ1OE1 of 1 models qualify · AHRI 21382984780.6(50 is the typical model of its size class) (higher)DOD33-24HFN1-MT0Wwith ducted air handler DTIU-24HWFN1-M1 of 1 models qualify · AHRI 214797741
Ducted, 2.5 to 3 tons55.5(50 is the typical model of its size class)ENVBR36HPJ1OAwith ducted air handler ENVBR36HPJ1IB4 of 4 models qualify · AHRI 20813026557.7(50 is the typical model of its size class) (higher)D3OJ-27HFN1-M1 of 4 models qualify · AHRI 211911392
Ducted, 3.5 to 4.5 tons58.3(50 is the typical model of its size class)ENVBR60HPJ1OAwith ducted air handler ENVBR48HPJ1IB1 of 1 models qualify · AHRI 208130266None on this board (0 of 4 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons74.0(50 is the typical model of its size class) (higher)MBRS18HPJ1OE13 of 15 models qualify · AHRI 21117434664.6(50 is the typical model of its size class)DOX230-09HFN1-MW5Wwith ductless indoor unit DCA3U-09HRFN1-M(C)3 of 9 models qualify · AHRI 214875723
Non-ducted, 2 tons77.3(50 is the typical model of its size class) (higher)MBRS24HPJ1OE2 of 3 models qualify · AHRI 21117434761.4(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ductless indoor unit DCD1-24HRFN1-MT0W(GA)1 of 2 models qualify · AHRI 214875724
Non-ducted, 2.5 to 3 tons74.7(50 is the typical model of its size class) (higher)MBRS42HPJ1OE7 of 8 models qualify · AHRI 21117435051.5(50 is the typical model of its size class)D3OJ-27HFN1-M1 of 5 models qualify · AHRI 211911391
Non-ducted, 3.5 to 4.5 tonsNo models in this size classNone on this board (0 of 3 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBOREALAll-around score, best modelDUOHOMEAll-around score, best model
Ducted, up to 1.5 tons55.6(50 is the typical model of its size class)KULA12HPJ1OBwith ducted air handler BDUCT12HPJ1DA2 of 2 models have all five ratings · AHRI 21746405578.8(50 is the typical model of its size class) (higher)DOX430-18HFN1-MU0Wwith ducted air handler DTIU-18HWFN1-M2 of 2 models have all five ratings · AHRI 214797740
Ducted, 2 tons60.8(50 is the typical model of its size class)ENVBR36HPJ1OAwith ducted air handler ENVBR24HPJ1IB2 of 2 models have all five ratings · AHRI 20813026484.0(50 is the typical model of its size class) (higher)DOD33-24HFN1-MT0Wwith ducted air handler DTIU-24HWFN1-M1 of 1 models have all five ratings · AHRI 214797741
Ducted, 2.5 to 3 tons53.0(50 is the typical model of its size class)MBRS30HPJ1OE3 of 3 models have all five ratings · AHRI 21382984871.7(50 is the typical model of its size class) (higher)D3OJ-27HFN1-M3 of 4 models have all five ratings · AHRI 211911392
Ducted, 3.5 to 4.5 tons63.3(50 is the typical model of its size class)ENVBR60HPJ1OAwith ducted air handler ENVBR48HPJ1IB1 of 1 models have all five ratings · AHRI 20813026663.5(50 is the typical model of its size class) (higher)D5OG-48HFN1-M3 of 4 models have all five ratings · AHRI 211911398
Ducted, 5 tons and upNo models in this size class54.3(50 is the typical model of its size class)DOE30U-60HFN1-Mwith ducted air handler DHG-60HWFN1-MW1 of 1 models have all five ratings · AHRI 206314613
Non-ducted, up to 1.5 tons79.6(50 is the typical model of its size class) (higher)KULA09HPL1OBwith ductless indoor unit KULA09HPL1IB15 of 15 models have all five ratings · AHRI 21382984172.1(50 is the typical model of its size class)DOX230-12HFN1-MV5Wwith ductless indoor unit DCA3U-12HRFN1-M(C)9 of 9 models have all five ratings · AHRI 214875728
Non-ducted, 2 tons72.2(50 is the typical model of its size class) (higher)MBRS24HPJ1OE3 of 3 models have all five ratings · AHRI 21117434767.4(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ductless indoor unit DCD1-24HRFN1-MT0W(GA)2 of 2 models have all five ratings · AHRI 214875724
Non-ducted, 2.5 to 3 tons70.9(50 is the typical model of its size class) (higher)MBRS42HPJ1OE7 of 8 models have all five ratings · AHRI 21117435068.0(50 is the typical model of its size class)D3OJ-27HFN1-M4 of 5 models have all five ratings · AHRI 211911391
Non-ducted, 3.5 to 4.5 tonsNo models in this size class48.3(50 is the typical model of its size class)D5OG-48HFN1-M3 of 3 models have all five ratings · AHRI 211911397

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBOREALDUOHOME
COP at 5°Fbeats 89% · 2.21MBRS18HPJ1OENon-ducted, up to 1.5 tonsbeats 92% · 2.28DOX230-12HFN1-MV5WNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 86% · 89%MBRS30HPJ1OEDucted, 2.5 to 3 tonsbeats 72% · 59%DOE30U-60HFN1-MDucted, 5 tons and up
HSPF2beats 82% · 10.0MBRS30HPJ1OENon-ducted, 2.5 to 3 tonsbeats 98% · 11.2DOD33-24HFN1-MT0WDucted, 2 tons
SEER2beats 95% · 27.0KULA09HPL1OBNon-ducted, up to 1.5 tonsbeats 98% · 21.0D3OJ-27HFN1-MDucted, 2.5 to 3 tons
EER2beats 89% · 14.6KULA09HPL1OBNon-ducted, up to 1.5 tonsbeats 85% · 12.5DOD33-24HFN1-MT0WDucted, 2 tons
Heating capacity at 5°Fbeats 87% · 14,500 Btu/hKULA18HPJ1OBNon-ducted, up to 1.5 tonsbeats 77% · 12,900 Btu/hD2OA-18HFN1-MNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BOREAL vs DUOHOME: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,707 models (37.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BOREAL (median, middle 50%)
  • DUOHOME (median, middle 50%)
Heating capacity, % of its 47°F maximum70%58%COP at maximum capacity1.821.95

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,707100%100%100%100%100%
All rated models, 17°F3,70765%68%76%83%92%
All rated models, 5°F3,70755%58%67%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7072.642.873.13.323.53
All rated models, 17°F3,7071.982.052.22.342.49
All rated models, 5°F3,7071.81.831.922.032.21
BOREAL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BOREAL, 47°F21100%100%100%100%100%
BOREAL, 17°F2175%77%87%91%100%
BOREAL, 5°F2157%65%70%75%75%
BOREAL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BOREAL, 47°F212.9933.173.323.4
BOREAL, 17°F212.032.052.122.32.4
BOREAL, 5°F211.751.81.821.872.1
DUOHOME: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
DUOHOME, 47°F18100%100%100%100%100%
DUOHOME, 17°F1863%66%68%71%75%
DUOHOME, 5°F1852%55%58%63%65%
DUOHOME: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
DUOHOME, 47°F182.632.773.083.233.54
DUOHOME, 17°F181.952.062.172.252.4
DUOHOME, 5°F181.81.811.952.052.29

Source: NEEP ccASHP list · as of

More comparisons