Skip to content

BROCK vs ForestAir heat pumps

Measured against models of the same size and duct type, ForestAir scores higher on 4 of the 6 ratings. BROCK has 24 outdoor models, ForestAir has 22 outdoor models. BROCK and ForestAir have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BROCK and ForestAir on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ForestAir scores higher on 4 of the 6 ratings.
  • BROCK
  • ForestAir
  • Other ranked manufacturers
BROCKForestAir

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBROCKForestAir
Efficiency index42%median —58%median —
COP at 5°F62% (higher)median 2.1746% (higher)median 1.80
Capacity retention at 5°F14%median 46%56%median 77%
HSPF226%median 7.535%median 9.0
SEER232%median 14.958%median 21.8
EER268% (higher)median 11.947% (higher)median 12.0
Heating capacity at 5°F17%median 17,150 Btu/h56%median 13,200 Btu/h
Outdoor models2422
AHRI certifications2,98624

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBROCKForestAir
CEE 2025 Tier 1 (Split ASHP)16.7%4 models68.2%15 models
CEE 2026 Tier 1 (Split ASHP)12.5%3 models68.2%15 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models54.5%12 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models4.5%1 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 2 groups where both have models
  • BROCK
  • ForestAir
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBROCKForestAir
Ducted, up to 1.5 tons1 · index 39%None
Ducted, 2 tons3 · index 38%1 · index 61%
Ducted, 2.5 to 3 tons7 · index 40%None
Ducted, 3.5 to 4.5 tons10 · index 43%1 · index 63%
Ducted, 5 tons and up3 · index 65%None
Non-ducted, up to 1.5 tonsNone14 · index 57%
Non-ducted, 2 tonsNone4 · index 59%
Non-ducted, 2.5 to 3 tonsNone2 · index 53%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBROCKCold-climate score, best modelForestAirCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)No models in this size class
Ducted, 2 tonsNone on this board (0 of 3 models qualify)No models in this size class
Ducted, 2.5 to 3 tonsNone on this board (0 of 7 models qualify)55.4(50 is the typical model of its size class)FAD36W/A-D(U)with ducted air handler FAD36AH2/A-D(U)1 of 1 models qualify · AHRI 208939392
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 10 models qualify)58.3(50 is the typical model of its size class)FAD60W/A-D(U)with ducted air handler FAD48AH2/A-D(U)1 of 1 models qualify · AHRI 208939393
Ducted, 5 tons and upNone on this board (0 of 3 models qualify)No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class69.8(50 is the typical model of its size class)FA-H12-D23TL/O-ESwith ductless indoor unit FA-H12-D23TL/I-ES9 of 14 models qualify · AHRI 207797362
Non-ducted, 2 tonsNo models in this size class52.4(50 is the typical model of its size class)FGH-24ES/E25-Owith ductless indoor unit FGH-24ES/E25-I1 of 4 models qualify · AHRI 211624984
Non-ducted, 2.5 to 3 tonsNo models in this size classNone on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBROCKAll-around score, best modelForestAirAll-around score, best model
Ducted, up to 1.5 tons41.2(50 is the typical model of its size class)PH5SAN418**AA*with indoor coil CAP**2517AL and furnace PG80ESUA36040B1 of 1 models have all five ratings · AHRI 211276012No models in this size class
Ducted, 2 tons62.2(50 is the typical model of its size class) (higher)PH7TAN424**AA*with indoor coil CAP**3721AL and furnace PG80VTLB60090C3 of 3 models have all five ratings · AHRI 21316919560.8(50 is the typical model of its size class)FAD36W/A-D(U)with ducted air handler FAD24AH2/A-D(U)1 of 1 models have all five ratings · AHRI 208939391
Ducted, 2.5 to 3 tons66.5(50 is the typical model of its size class)PH7TAN436**AA*with ducted air handler PF4TNBD60L5 of 7 models have all five ratings · AHRI 213925458No models in this size class
Ducted, 3.5 to 4.5 tons72.5(50 is the typical model of its size class) (higher)PH7TAN448**AA*with ducted air handler PF4TNBD60L8 of 10 models have all five ratings · AHRI 21328064963.3(50 is the typical model of its size class)FAD60W/A-D(U)with ducted air handler FAD48AH2/A-D(U)1 of 1 models have all five ratings · AHRI 208939393
Ducted, 5 tons and up64.9(50 is the typical model of its size class)PH5SAN460**AA*with ducted air handler PF4TNBD60L1 of 3 models have all five ratings · AHRI 213280500No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class71.5(50 is the typical model of its size class)FA-H12-D23TL/O-ESwith ductless indoor unit FA-H12-D23TL/I-ES10 of 14 models have all five ratings · AHRI 207797362
Non-ducted, 2 tonsNo models in this size class72.5(50 is the typical model of its size class)FGH-24ES/E25-Owith ductless indoor unit FGH-24ES/E25-I3 of 4 models have all five ratings · AHRI 211624984
Non-ducted, 2.5 to 3 tonsNo models in this size class52.7(50 is the typical model of its size class)FA-H36-D21TL/O4-ES1 of 2 models have all five ratings · AHRI 207804203

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBROCKForestAir
COP at 5°Fbeats 90% · 2.34PH7TAN436**AA*Ducted, 2.5 to 3 tonsbeats 89% · 2.21FA-H18-D23TL/O-ESNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 35% · 60%PH5SAN436**AA*Ducted, 2.5 to 3 tonsbeats 73% · 81%FAD60W/A-D(U)Ducted, 3.5 to 4.5 tons
HSPF2beats 52% · 8.1PH5SAN460**AA*Ducted, 5 tons and upbeats 73% · 9.0FAD60W/A-D(U)Ducted, 3.5 to 4.5 tons
SEER2beats 82% · 17.5PH7TAN448**AA*Ducted, 3.5 to 4.5 tonsbeats 97% · 24.0FGH-24ES/E25-ONon-ducted, 2 tons
EER2beats 99% · 12.5PH5SAN460**AA*Ducted, 5 tons and upbeats 90% · 14.7FGH-09ES/E25-ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 40% · 30,200 Btu/hPH7TAN460**AA*Ducted, 3.5 to 4.5 tonsbeats 87% · 14,500 Btu/hFGH-18ES/E25-ONon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter