Skip to content

BROCK vs NG Trade heat pumps

Measured against models of the same size and duct type, NG Trade scores higher on 4 of the 6 ratings. BROCK has 24 outdoor models, NG Trade has 15 outdoor models. BROCK and NG Trade have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BROCK and NG Trade on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, NG Trade scores higher on 4 of the 6 ratings.
  • BROCK
  • NG Trade
  • Other ranked manufacturers
BROCKNG Trade

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBROCKNG Trade
Efficiency index42%median —56%median —
COP at 5°F62% (higher)median 2.1750% (higher)median 1.90
Capacity retention at 5°F14%median 46%41%median 67%
HSPF226%median 7.559%median 9.2
SEER232%median 14.967%median 21.4
EER268% (higher)median 11.955% (higher)median 12.2
Heating capacity at 5°F17%median 17,150 Btu/h43%median 12,600 Btu/h
Outdoor models2415
AHRI certifications2,98625

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBROCKNG Trade
CEE 2025 Tier 1 (Split ASHP)16.7%4 models80%12 models
CEE 2026 Tier 1 (Split ASHP)12.5%3 models73.3%11 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models46.7%7 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models33.3%5 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • BROCK
  • NG Trade
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBROCKNG Trade
Ducted, up to 1.5 tons1 · index 39%1 · index 60%
Ducted, 2 tons3 · index 38%None
Ducted, 2.5 to 3 tons7 · index 40%2 · index 64%
Ducted, 3.5 to 4.5 tons10 · index 43%1 · index 64%
Ducted, 5 tons and up3 · index 65%None
Non-ducted, up to 1.5 tonsNone9 · index 56%
Non-ducted, 2 tonsNone2 · index 48%
Non-ducted, 2.5 to 3 tonsNone3 · index 53%
Non-ducted, 3.5 to 4.5 tonsNone1 · index 48%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBROCKCold-climate score, best modelNG TradeCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)52.6(50 is the typical model of its size class)MOBMH180C1 of 1 models qualify · AHRI 213307863
Ducted, 2 tonsNone on this board (0 of 3 models qualify)No models in this size class
Ducted, 2.5 to 3 tonsNone on this board (0 of 7 models qualify)57.6(50 is the typical model of its size class)MOBMH270C1 of 2 models qualify · AHRI 213307866
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 10 models qualify)None on this board (0 of 1 models qualify)
Ducted, 5 tons and upNone on this board (0 of 3 models qualify)No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class76.3(50 is the typical model of its size class)OMEGA181Ewith ductless indoor unit IMEGA181E4 of 9 models qualify · AHRI 214442655
Non-ducted, 2 tonsNo models in this size class66.2(50 is the typical model of its size class)OMEGA241Ewith ductless indoor unit IMEGA241E1 of 2 models qualify · AHRI 214377801
Non-ducted, 2.5 to 3 tonsNo models in this size class51.5(50 is the typical model of its size class)MOBMH270C1 of 3 models qualify · AHRI 213307865
Non-ducted, 3.5 to 4.5 tonsNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBROCKAll-around score, best modelNG TradeAll-around score, best model
Ducted, up to 1.5 tons41.2(50 is the typical model of its size class)PH5SAN418**AA*with indoor coil CAP**2517AL and furnace PG80ESUA36040B1 of 1 models have all five ratings · AHRI 21127601259.8(50 is the typical model of its size class) (higher)MOBMH180C1 of 1 models have all five ratings · AHRI 213307863
Ducted, 2 tons62.2(50 is the typical model of its size class)PH7TAN424**AA*with indoor coil CAP**3721AL and furnace PG80VTLB60090C3 of 3 models have all five ratings · AHRI 213169195No models in this size class
Ducted, 2.5 to 3 tons66.5(50 is the typical model of its size class)PH7TAN436**AA*with ducted air handler PF4TNBD60L5 of 7 models have all five ratings · AHRI 21392545871.7(50 is the typical model of its size class) (higher)MOBMH270C2 of 2 models have all five ratings · AHRI 213307866
Ducted, 3.5 to 4.5 tons72.5(50 is the typical model of its size class) (higher)PH7TAN448**AA*with ducted air handler PF4TNBD60L8 of 10 models have all five ratings · AHRI 21328064963.5(50 is the typical model of its size class)MOBMH480C1 of 1 models have all five ratings · AHRI 213867401
Ducted, 5 tons and up64.9(50 is the typical model of its size class)PH5SAN460**AA*with ducted air handler PF4TNBD60L1 of 3 models have all five ratings · AHRI 213280500No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class85.0(50 is the typical model of its size class)OMEGA091Ewith ductless indoor unit IMEGA091E9 of 9 models have all five ratings · AHRI 214377798
Non-ducted, 2 tonsNo models in this size class73.3(50 is the typical model of its size class)OMEGA241Ewith ductless indoor unit IMEGA241E2 of 2 models have all five ratings · AHRI 214377801
Non-ducted, 2.5 to 3 tonsNo models in this size class68.0(50 is the typical model of its size class)MOBMH270C3 of 3 models have all five ratings · AHRI 213307865
Non-ducted, 3.5 to 4.5 tonsNo models in this size class48.3(50 is the typical model of its size class)MOBMH480C1 of 1 models have all five ratings · AHRI 213867400

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBROCKNG Trade
COP at 5°Fbeats 90% · 2.34PH7TAN436**AA*Ducted, 2.5 to 3 tonsbeats 97% · 2.22OMEGA241ENon-ducted, 2 tons
Capacity retention at 5°Fbeats 35% · 60%PH5SAN436**AA*Ducted, 2.5 to 3 tonsbeats 79% · 99%OMEGA181ENon-ducted, up to 1.5 tons
HSPF2beats 52% · 8.1PH5SAN460**AA*Ducted, 5 tons and upbeats 95% · 9.7MOBMH480CDucted, 3.5 to 4.5 tons
SEER2beats 82% · 17.5PH7TAN448**AA*Ducted, 3.5 to 4.5 tonsbeats 98% · 21.0MOBMH270CDucted, 2.5 to 3 tons
EER2beats 99% · 12.5PH5SAN460**AA*Ducted, 5 tons and upbeats 95% · 15.8OMEGA091ENon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 40% · 30,200 Btu/hPH7TAN460**AA*Ducted, 3.5 to 4.5 tonsbeats 91% · 17,742 Btu/hOMEGA181ENon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter