Skip to content

CanAir vs ENERGI AIR: heat pump ratings compared

Against heat pumps of the same size and type, a typical CanAir model beats 56% and a typical ENERGI AIR model 39%. CanAir rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

CanAir

56%

of similar heat pumps beaten by its typical model

Above average

44 models listed

ENERGI AIR

39%

of similar heat pumps beaten by its typical model

Well below average

46 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCanAir: Beats 50%ENERGI AIR: Beats 40%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCanAir: Beats 58%ENERGI AIR: Beats 13%
  • Winter-long heating efficiencyHSPF2CanAir: Beats 70%ENERGI AIR: Beats 21%
  • Summer-long cooling efficiencySEER2CanAir: Beats 57%ENERGI AIR: Beats 31%
  • Hot-day cooling efficiencyEER2CanAir: Beats 47%ENERGI AIR: Beats 67%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    CanAir
    64%
    ENERGI AIR
    7%
  • Xcel CC

    CanAir
    57%
    ENERGI AIR
    0%
  • CEE Advanced

    CanAir
    0%
    ENERGI AIR
    0%
  • ENERGY STAR CC

    CanAir
    59%
    ENERGI AIR
    0%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

CanAir

  1. 1C28MC328H21CanAir2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 66.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    74.7score / 100Heating 67 · Cooling 83
  2. 2C28MC436H22CanAir3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 64.0Meets none of the standards tracked here
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.70 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Good
    71.4score / 100Heating 64 · Cooling 79
  3. 3CDH2036C22with ducted air handler CDH2036F21CanAir3 tons · 35,000 Btu/h · DuctedCold-climate pick, score 68.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    97% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    16.3 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Good
    68.5score / 100Heating 69 · Cooling 68

ENERGI AIR

  1. 1GSZC703610A*with ducted air handler CAPTA4230*4A*+MBVC2001**-1AENERGI AIR3 tons · 34,800 Btu/h · DuctedNot a cold-climate pick: keeps 50% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    50% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    8.2 (HSPF2)
    Good
    Cooling efficiency
    17.2 (SEER2)
    Good
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    64.3score / 100Heating 45 · Cooling 84
  2. 2GSZH503610A*with ducted air handler CAPTA4230*4A*+MBVC1601**-1AENERGI AIR3 tons · 34,200 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    52% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    58.5score / 100Heating 41 · Cooling 76
  3. 3GSZH503010A*with indoor coil CAPTA4230*4A and furnace GM9S960805CUAENERGI AIR2.5 tons · 28,400 Btu/h · DuctedNot a cold-climate pick: keeps 47% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    49% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.95 (COP at 5°F)
    Good
    Winter efficiency
    7.5 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    54.0score / 100Heating 32 · Cooling 76

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter