Skip to content

CARRIER CORPORATION vs KLIMAIRE heat pumps

Measured against models of the same size and duct type, KLIMAIRE scores higher on 5 of the 6 ratings. CARRIER CORPORATION has 64 outdoor models, KLIMAIRE has 63 outdoor models. CARRIER CORPORATION and KLIMAIRE have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CARRIER CORPORATION and KLIMAIRE on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, KLIMAIRE scores higher on 5 of the 6 ratings.
  • CARRIER CORPORATION
  • KLIMAIRE
  • Other ranked manufacturers
CARRIER …KLIMAIRE

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCARRIER CORPORATIONKLIMAIRE
Efficiency index41%median —52%median —
COP at 5°F20%median 1.7546%median 1.90
Capacity retention at 5°F10%median 40%44%median 66%
HSPF223%median 7.153%median 9.0
SEER246%median 16.054%median 19.0
EER277% (higher)median 11.740% (higher)median 10.0
Heating capacity at 5°F6%median 17,250 Btu/h44%median 15,500 Btu/h
Outdoor models6463
AHRI certifications64107

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCARRIER CORPORATIONKLIMAIRE
CEE 2025 Tier 1 (Split ASHP)0%0 models52.4%33 models
CEE 2026 Tier 1 (Split ASHP)0%0 models46%29 models
CEE Advanced Tier (Split ASHP)0%0 models1.6%1 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models33.3%21 models
DOE Cold Climate Heat Pump Challenge0%0 models1.6%1 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 3 groups where both have models
  • CARRIER CORPORATION
  • KLIMAIRE
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCARRIER CORPORATIONKLIMAIRE
Ducted, 2.5–3 tons21 · index 41%7 · index 57%
Ducted, 3.5–4.5 tons22 · index 37%5 · index 53%
Ducted, 5 tons and up21 · index 52%3 · index 56%
Ducted, up to 1.5 tonsNone7 · index 68%
Ducted, 2 tonsNone4 · index 76%
Non-ducted, up to 1.5 tonsNone29 · index 49%
Non-ducted, 2 tonsNone8 · index 49%
Non-ducted, 2.5–3 tonsNone15 · index 40%
Non-ducted, 3.5–4.5 tonsNone6 · index 41%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCARRIER CORPORATIONCold-climate score, best modelKLIMAIRECold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class74.9(50 is the typical model of its size class)KSIH009-H225-O-2with ducted air handler KDIP09-H26 of 7 models qualify · AHRI 209862170
Ducted, 2 tonsNo models in this size class80.3(50 is the typical model of its size class)KSIE024-H220-O-2with ducted air handler KDIP24-H24 of 4 models qualify · AHRI 209862163
Ducted, 2.5–3 tonsNone on this board (0 of 21 models qualify)74.7(50 is the typical model of its size class)KOIF36H2-1Swith ducted air handler KIDF36H2-1S3 of 7 models qualify · AHRI 212316042
Ducted, 3.5–4.5 tonsNone on this board (0 of 22 models qualify)73.8(50 is the typical model of its size class)KOIF48H2-1Swith ducted air handler KIDF48H2-1S2 of 5 models qualify · AHRI 212316043
Ducted, 5 tons and upNone on this board (0 of 21 models qualify)None on this board (0 of 3 models qualify)
Non-ducted, up to 1.5 tonsNo models in this size class80.2(50 is the typical model of its size class)KSIE009-H221-O-2with ductless indoor unit KSIE009-H221-IW-212 of 29 models qualify · AHRI 209862149
Non-ducted, 2 tonsNo models in this size class86.1(50 is the typical model of its size class)KSIH024-H220-O-2with ductless indoor unit KTIS24-H23 of 8 models qualify · AHRI 212316044
Non-ducted, 2.5–3 tonsNo models in this size class49.3(50 is the typical model of its size class)KMIR327-H217-22 of 15 models qualify · AHRI 209862187
Non-ducted, 3.5–4.5 tonsNo models in this size class56.3(50 is the typical model of its size class)KSIR048-H218-2with ductless indoor unit KFUF048-H2G11 of 6 models qualify · AHRI 209862179

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCARRIER CORPORATIONAll-around score, best modelKLIMAIREAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class85.2(50 is the typical model of its size class)KSIH009-H225-O-2with ducted air handler KDIP09-H27 of 7 models have all five ratings · AHRI 209862170
Ducted, 2 tonsNo models in this size class83.8(50 is the typical model of its size class)KSIE024-H220-O-2with ducted air handler KDIP24-H24 of 4 models have all five ratings · AHRI 209862163
Ducted, 2.5–3 tons41.3(50 is the typical model of its size class)50GCQ(T,H)04***3A*****1 of 21 models have all five ratings · AHRI 21661284972.0(50 is the typical model of its size class) (higher)KMIR430-H217-26 of 7 models have all five ratings · AHRI 209862191
Ducted, 3.5–4.5 tons50.5(50 is the typical model of its size class)50GCQ(T,H)05***3A*****2 of 22 models have all five ratings · AHRI 21661285063.5(50 is the typical model of its size class) (higher)KMIR545-H219-24 of 5 models have all five ratings · AHRI 209862197
Ducted, 5 tons and up51.5(50 is the typical model of its size class)50GCQ(T,H)06***3A*****1 of 21 models have all five ratings · AHRI 21661303557.1(50 is the typical model of its size class) (higher)KSIR060-H218-2with ducted air handler KDIS060-H2G1Also listed as KSIR060-H218-2(3)3 of 3 models have all five ratings · AHRI 209862177
Non-ducted, up to 1.5 tonsNo models in this size class84.4(50 is the typical model of its size class)KSIH009-H225-O-2with ductless indoor unit KSIH009-H225-IW-224 of 29 models have all five ratings · AHRI 209862153
Non-ducted, 2 tonsNo models in this size class72.0(50 is the typical model of its size class)KSIE024-H220-O-2with ductless indoor unit KUIR24-H26 of 8 models have all five ratings · AHRI 209862165
Non-ducted, 2.5–3 tonsNo models in this size class66.7(50 is the typical model of its size class)KMIR327-H217-210 of 15 models have all five ratings · AHRI 209862187
Non-ducted, 3.5–4.5 tonsNo models in this size class48.3(50 is the typical model of its size class)KMIR545-H219-24 of 6 models have all five ratings · AHRI 209862196

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCARRIER CORPORATIONKLIMAIRE
COP at 5°Fbeats 32% · 1.8450GCQ(T,H)05***3A*****Ducted, 3.5–4.5 tonsbeats 96% · 2.38KSIE018-H220-O-2Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 21% · 40%50GCQ(T,H)06***3A*****Ducted, 5 tons and upbeats 93% · 108%KSIH009-H225-O-2Ducted, up to 1.5 tons
HSPF2beats 40% · 7.550GCQ(J,L)06***1*Also listed as 50GCQ(J,L)06***5, 50GCQ(J,L)06***6, 50GCQ(M,P)06***1, 50GCQ(M,P)06***6 and 8 moreDucted, 5 tons and upbeats 98% · 12.0KSIH009-H225-O-2Ducted, up to 1.5 tons
SEER2beats 70% · 16.050GCQ(J,L)06***1*Also listed as 50GCQ(J,L)06***5, 50GCQ(J,L)06***6, 50GCQ(M,P)06***1, 50GCQ(M,P)06***6 and 8 moreDucted, 5 tons and upbeats 98% · 21.0KMIR327-H217-2Ducted, 2.5–3 tons
EER2beats 89% · 12.050GCQ(J,L)06***1*Also listed as 50GCQ(J,L)06***5, 50GCQ(J,L)06***6, 50GCQ(M,P)06***1, 50GCQ(M,P)06***6 and 8 moreDucted, 5 tons and upbeats 95% · 15.8KSIH009-H225-O-2Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 9% · 17,900 Btu/h50GCQ(T,H)05***3A*****Ducted, 3.5–4.5 tonsbeats 95% · 48,500 Btu/hKOIF60H2-1SDucted, 3.5–4.5 tons