Skip to content

CARRIER CORPORATION vs KLIMAIRE heat pumps

Measured against models of the same size and duct type, KLIMAIRE scores higher on 5 of the 6 ratings. CARRIER CORPORATION has 8 outdoor models, KLIMAIRE has 25 outdoor models. CARRIER CORPORATION and KLIMAIRE have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CARRIER CORPORATION and KLIMAIRE on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, KLIMAIRE scores higher on 5 of the 6 ratings.
  • CARRIER CORPORATION
  • KLIMAIRE
  • Other ranked manufacturers
CARRIER …KLIMAIRE

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCARRIER CORPORATIONKLIMAIRE
Efficiency index19%median —55%median —
COP at 5°F3%median 1.4750%median 2.00
Capacity retention at 5°F3%median 34%48%median 72%
HSPF210%median 6.760%median 10.0
SEER29%median 13.461%median 21.2
EER258% (higher)median 11.552% (higher)median 12.0
Heating capacity at 5°F5%median 14,450 Btu/h55%median 18,900 Btu/h
Outdoor models825
AHRI certifications845

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCARRIER CORPORATIONKLIMAIRE
CEE 2025 Tier 1 (Split ASHP)0%0 models76%19 models
CEE 2026 Tier 1 (Split ASHP)0%0 models76%19 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models72%18 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • CARRIER CORPORATION
  • KLIMAIRE
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCARRIER CORPORATIONKLIMAIRE
Ducted, 2.5–3 tons4 · index 17%3 · index 77%
Ducted, 5 tons and up4 · index 21%1 · index 63%
Ducted, up to 1.5 tonsNone2 · index 76%
Ducted, 2 tonsNone1 · index 65%
Ducted, 3.5–4.5 tonsNone3 · index 84%
Non-ducted, up to 1.5 tonsNone10 · index 47%
Non-ducted, 2 tonsNone3 · index 40%
Non-ducted, 2.5–3 tonsNone7 · index 45%
Non-ducted, 3.5–4.5 tonsNone4 · index 53%
Non-ducted, 5 tons and upNone1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCARRIER CORPORATIONCold-climate score, best modelKLIMAIRECold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class72.6(50 is the typical model of its size class)KMIR319-H221-42 of 2 models qualify · AHRI 217489269
Ducted, 2 tonsNo models in this size class48.6(50 is the typical model of its size class)KMIR427-H225-41 of 1 models qualify · AHRI 217489272
Ducted, 2.5–3 tonsNone on this board (0 of 4 models qualify)82.5(50 is the typical model of its size class)KMHR536-H224-43 of 3 models qualify · AHRI 217489290
Ducted, 3.5–4.5 tonsNo models in this size class82.7(50 is the typical model of its size class)KMHR648-H224-43 of 3 models qualify · AHRI 217489293
Ducted, 5 tons and upNone on this board (0 of 4 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tonsNo models in this size class68.6(50 is the typical model of its size class)KMIP218-H225-47 of 10 models qualify · AHRI 218067072
Non-ducted, 2 tonsNo models in this size class41.1(50 is the typical model of its size class)KMIR427-H225-42 of 3 models qualify · AHRI 217489271
Non-ducted, 2.5–3 tonsNo models in this size class72.6(50 is the typical model of its size class)KMHR536-H224-45 of 7 models qualify · AHRI 217489291
Non-ducted, 3.5–4.5 tonsNo models in this size class69.9(50 is the typical model of its size class)KMHR660-H218-44 of 4 models qualify · AHRI 217489297
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCARRIER CORPORATIONAll-around score, best modelKLIMAIREAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class77.4(50 is the typical model of its size class)KMHR319-H221-42 of 2 models have all five ratings · AHRI 217489284
Ducted, 2 tonsNo models in this size class64.5(50 is the typical model of its size class)KMIR427-H225-41 of 1 models have all five ratings · AHRI 217489272
Ducted, 2.5–3 tons17.3(50 is the typical model of its size class)50FEQ*04***3******1 of 4 models have all five ratings · AHRI 21657494483.6(50 is the typical model of its size class) (higher)KMHR536-H224-43 of 3 models have all five ratings · AHRI 217489290
Ducted, 3.5–4.5 tonsNo models in this size class85.1(50 is the typical model of its size class)KMIR648-H224-43 of 3 models have all five ratings · AHRI 217489278
Ducted, 5 tons and up21.3(50 is the typical model of its size class)50FEQ*06***3******1 of 4 models have all five ratings · AHRI 21657494562.5(50 is the typical model of its size class) (higher)KMIR660-H218-41 of 1 models have all five ratings · AHRI 217489281
Non-ducted, up to 1.5 tonsNo models in this size class72.2(50 is the typical model of its size class)KMIP218-H225-410 of 10 models have all five ratings · AHRI 218067072
Non-ducted, 2 tonsNo models in this size class56.7(50 is the typical model of its size class)KMIR427-H225-43 of 3 models have all five ratings · AHRI 217489271
Non-ducted, 2.5–3 tonsNo models in this size class66.3(50 is the typical model of its size class)KMHR536-H224-47 of 7 models have all five ratings · AHRI 217489289
Non-ducted, 3.5–4.5 tonsNo models in this size class62.6(50 is the typical model of its size class)KMHR660-H218-44 of 4 models have all five ratings · AHRI 217489295
Non-ducted, 5 tons and upNo models in this size class32.5(50 is the typical model of its size class)KMIR660-H218-41 of 1 models have all five ratings · AHRI 217489280

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCARRIER CORPORATIONKLIMAIRE
COP at 5°Fbeats 5% · 1.6050FEQ*04***3******Ducted, 2.5–3 tonsbeats 89% · 2.25KMIR319-H221-4Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 5% · 39%50FEQ*04***3******Ducted, 2.5–3 tonsbeats 95% · 104%KMHR536-H224-4Non-ducted, 2.5–3 tons
HSPF2beats 10% · 6.750FEQ*06***1******Also listed as 50FEQ*06***5, 50FEQ*06***6Ducted, 5 tons and upbeats 99% · 11.0KMHR648-H224-4Ducted, 3.5–4.5 tons
SEER2beats 9% · 13.450FEQ*06***1******Also listed as 50FEQ*06***5, 50FEQ*06***6Ducted, 5 tons and upbeats 96% · 20.4KMIR648-H224-4Ducted, 3.5–4.5 tons
EER2beats 60% · 11.550FEQ*06***1******Also listed as 50FEQ*06***5, 50FEQ*06***6Ducted, 5 tons and upbeats 85% · 13.0KMHR319-H221-4Ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 8% · 13,400 Btu/h50FEQ*04***3******Ducted, 2.5–3 tonsbeats 94% · 37,400 Btu/hKMHR536-H224-4Non-ducted, 2.5–3 tons