Carrier vs Ecoer: heat pump ratings compared

Against heat pumps of the same size and type, a typical Carrier model beats 47% and a typical Ecoer model 70%. Ecoer rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

Carrier

47%

of similar heat pumps beaten by its typical model

About average

701 models listed

Ecoer

70%

of similar heat pumps beaten by its typical model

Well above average

13 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 59%Ecoer: Beats 74%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 32%Ecoer: Beats 67%
  • Winter-long heating efficiencyHSPF2Carrier: Beats 38%Ecoer: Beats 72%
  • Summer-long cooling efficiencySEER2Carrier: Beats 45%Ecoer: Beats 74%
  • Hot-day cooling efficiencyEER2Carrier: Beats 59%Ecoer: Beats 66%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Carrier
    29%
    Ecoer
    92%
  • Xcel CC

    Carrier
    17%
    Ecoer
    100%
  • CEE Advanced

    Carrier
    2%
    Ecoer
    0%
  • ENERGY STAR CC

    Carrier
    9%
    Ecoer
    46%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

Carrier

  1. 1MCY-MAP0367HS-ULCarrier (sold as Toshiba Carrier)3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 87.8Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    3.05 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.9 (HSPF2)
    Top 10%
    Cooling efficiency
    20.1 (SEER2)
    Top 10%
    Hot-day cooling
    12.1 (EER2)
    Top 10%
    91.1score / 100Heating 88 · Cooling 94
  2. 2MCY-MAP0367HS-UL*Carrier (sold as Toshiba Carrier)3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 87.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    78% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.70 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.9 (HSPF2)
    Top 10%
    Cooling efficiency
    20.1 (SEER2)
    Top 10%
    Hot-day cooling
    12.1 (EER2)
    Top 10%
    90.7score / 100Heating 87 · Cooling 94
  3. 3RAV-SP302AT2P-ULwith ducted air handler RAV-SM302BTP-ULCarrier (sold as Toshiba Carrier)2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 82.1Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    75% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.19 (COP at 5°F)
    Great
    Winter efficiency
    10.3 (HSPF2)
    Top 10%
    Cooling efficiency
    19.3 (SEER2)
    Great
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    86.5score / 100Heating 82 · Cooling 91

Ecoer

  1. 1EODA18H-4860Bwith ducted air handler EAHATN-36BEcoerAlso listed as EODA18H-4860BAA3 tons · 35,200 Btu/h · DuctedCold-climate pick, score 76.4Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    80.5score / 100Heating 75 · Cooling 86
  2. 2EODA18H-4860with ducted air handler EAHATN-36BEcoer3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 67.7Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    78% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    8.5 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    75.4score / 100Heating 68 · Cooling 83
  3. 3ESCA16H-36with ducted air handler EAHAEC-36Ecoer3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 78.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    86% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.97 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    56.1score / 100Heating 75 · Cooling 37

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter