Skip to content

Carrier vs GE Appliances heat pumps

Measured against models of the same size and duct type, GE Appliances scores higher on 4 of the 6 ratings. Carrier has 701 outdoor models, GE Appliances has 66 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and GE Appliances on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, GE Appliances scores higher on 4 of the 6 ratings.
  • Carrier
  • GE Appliances
  • Other ranked manufacturers
CarrierGE Appli…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierGE Appliances
Efficiency index47%median — · 22nd ranked50%median — · 20th ranked
COP at 5°F59% (higher)median 2.00 · 7th ranked46% (higher)median 1.90 · 21st ranked
Capacity retention at 5°F32%median 53% · 27th ranked46%median 69% · 20th ranked
HSPF238%median 7.7 · 21st ranked51%median 9.0 · 15th ranked
SEER245%median 15.5 · 20th ranked47%median 18.0 · 18th ranked
EER259% (higher)median 11.5 · 6th ranked50% (higher)median 11.7 · 15th ranked
Heating capacity at 5°F35%median 18,300 Btu/h · 27th ranked47%median 17,000 Btu/h · 19th ranked
Outdoor models70166
AHRI certifications367,4546,882

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierGE Appliances
CEE 2025 Tier 1 (Split ASHP)28.5%200 models62.1%41 models
CEE 2026 Tier 1 (Split ASHP)25.5%179 models60.6%40 models
CEE Advanced Tier (Split ASHP)2%14 models3%2 models
Xcel Energy Colorado cold-climate ASHP (2025)17.1%120 models36.4%24 models
DOE Cold Climate Heat Pump Challenge2%14 models3%2 models
ENERGY STAR Cold Climate8.8%62 models27.3%18 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Carrier
  • GE Appliances
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsNon-ducted, 5 tons and up2.0137 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierGE Appliances
Ducted, up to 1.5 tons34 · index 48%9 · index 42%
Ducted, 2 tons100 · index 47%9 · index 53%
Ducted, 2.5 to 3 tons195 · index 47%10 · index 53%
Ducted, 3.5 to 4.5 tons256 · index 43%15 · index 54%
Ducted, 5 tons and up67 · index 61%None
Non-ducted, up to 1.5 tons42 · index 56%24 · index 54%
Non-ducted, 2 tons9 · index 54%8 · index 45%
Non-ducted, 2.5 to 3 tons31 · index 53%4 · index 37%
Non-ducted, 3.5 to 4.5 tons17 · index 48%2 · index 18%
Non-ducted, 5 tons and up1 · index 87%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelGE AppliancesCold-climate score, best model
Ducted, up to 1.5 tons81.6(50 is the typical model of its size class) (higher)38MARBQ18AA3with ducted air handler 40MBDAQ18XH3Also sold as Arcoaire DLCSRBH18AAK21 of 33 models qualify · AHRI 21113291853.8(50 is the typical model of its size class)ASH220NCDD**4 of 9 models qualify · AHRI 210154190
Ducted, 2 tons95.9(50 is the typical model of its size class) (higher)38MURAQ24AB3*with indoor coil H,PG7J936 and furnace 927TA48060V1735 of 99 models qualify · AHRI 21676197367.5(50 is the typical model of its size class)NS22H24MA4-**Awith ducted air handler NAM30V2TA43 of 9 models qualify · AHRI 212396412
Ducted, 2.5 to 3 tons96.4(50 is the typical model of its size class) (higher)38MURAQ36AB3*with indoor coil H,PG48936 and furnace 927TA60080V2143 of 197 models qualify · AHRI 21676198869.5(50 is the typical model of its size class)AUH2436ZGDA*with ducted air handler F,PE*G339363 of 10 models qualify · AHRI 207764670
Ducted, 3.5 to 4.5 tons87.9(50 is the typical model of its size class) (higher)MCY-MAP0487HS-UL*26 of 256 models qualify · AHRI 21335025478.1(50 is the typical model of its size class)NS17H48SA4-**Awith indoor coil D(A,C,E)48D44+TDR and furnace NF97D070M3B-3 of 15 models qualify · AHRI 213884874
Ducted, 5 tons and up91.7(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 67 models qualify · AHRI 213350251No models in this size class
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class)38MARBQ06AA3with ductless indoor unit DHMAHBQ06XA3Also sold as Arcoaire DLCSRBH06AAK22 of 42 models qualify · AHRI 20718893596.0(50 is the typical model of its size class) (higher)ASH112URDE**with ductless indoor unit ASYW12URDE11 of 24 models qualify · AHRI 212409457
Non-ducted, 2 tons87.1(50 is the typical model of its size class) (higher)38MARBQ24AA3with ductless indoor unit 40MBCAQ24XA3Also sold as Arcoaire DLCSRBH24AAK5 of 9 models qualify · AHRI 20768329263.3(50 is the typical model of its size class)ASH324NCDD**5 of 8 models qualify · AHRI 210154192
Non-ducted, 2.5 to 3 tons86.6(50 is the typical model of its size class) (higher)MCY-MAP0367HS-UL*7 of 31 models qualify · AHRI 21335025568.2(50 is the typical model of its size class)ASH436NCDD**3 of 4 models qualify · AHRI 210154196
Non-ducted, 3.5 to 4.5 tons81.9(50 is the typical model of its size class) (higher)MCY-MAP0487HS-UL*11 of 17 models qualify · AHRI 21335025019.1(50 is the typical model of its size class)ASH4248UCDD**with ductless indoor unit USYL42UCDD1 of 2 models qualify · AHRI 211744614
Non-ducted, 5 tons and up92.6(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 1 models qualify · AHRI 213350252No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelGE AppliancesAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class) (higher)38MARBQ09AA3with ducted air handler 40MBDQ09---3Also sold as Arcoaire DLCSRBH09AAK32 of 33 models have all five ratings · AHRI 20635032861.4(50 is the typical model of its size class)NS17H18SA4-**Awith indoor coil D(A,C,E)24D34+TDR and furnace NF97D070M3B-7 of 9 models have all five ratings · AHRI 213884332
Ducted, 2 tons88.9(50 is the typical model of its size class) (higher)25VNA424A*031*with indoor coil CAP**3721AL*+UI and furnace 58TN*A090C17**16Also sold as Bryant Heating and Cooling Systems 284ANV024*0**B90 of 92 models have all five ratings · AHRI 21053300882.7(50 is the typical model of its size class)NS22H24MA4-**Awith ducted air handler NAM30V2TA49 of 10 models have all five ratings · AHRI 212396412
Ducted, 2.5 to 3 tons91.1(50 is the typical model of its size class) (higher)MCY-MAP0367HS-UL162 of 203 models have all five ratings · AHRI 1004987883.2(50 is the typical model of its size class)NS22H36MA4-**Awith indoor coil D(A,C,E)36D44+TDR and furnace NF97D070M3B-7 of 9 models have all five ratings · AHRI 213884682
Ducted, 3.5 to 4.5 tons92.2(50 is the typical model of its size class) (higher)25VNA448A*031*with ducted air handler FE4BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 284ANV048*0**B201 of 253 models have all five ratings · AHRI 21336159178.1(50 is the typical model of its size class)NS17H48SA4-**Awith indoor coil D(A,C,E)48D44+TDR and furnace NF80D110S5C-11 of 14 models have all five ratings · AHRI 213884846
Ducted, 5 tons and up91.2(50 is the typical model of its size class) (higher)25VNA460A*031*with ducted air handler FE4BNBD60L*+UI40 of 71 models have all five ratings · AHRI 21336159367.5(50 is the typical model of its size class)NS17H60SA4-**Awith indoor coil NCUC60CT5D-**+TDR and furnace NF80U110T5C1 of 1 models have all five ratings · AHRI 217490085
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class)38MARBQ06AA3with ductless indoor unit DHMAHBQ06XA3Also sold as Arcoaire DLCSRBH06AAK40 of 42 models have all five ratings · AHRI 20718893594.9(50 is the typical model of its size class) (higher)ASH112URDE**with ductless indoor unit ASYW12URDE21 of 24 models have all five ratings · AHRI 212409457
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)38MARBQ24AA3with ductless indoor unit 40MAHBQ24XA3Also sold as Arcoaire DLCSRBH24AAK9 of 9 models have all five ratings · AHRI 20634813860.7(50 is the typical model of its size class)ASH324JCDD**8 of 8 models have all five ratings · AHRI 207698999
Non-ducted, 2.5 to 3 tons90.5(50 is the typical model of its size class) (higher)RAV-SP302AT2P-ULwith ductless indoor unit RAV-SM302UTP-UL27 of 31 models have all five ratings · AHRI 20844732449.7(50 is the typical model of its size class)ASH436NCDD**4 of 4 models have all five ratings · AHRI 210154196
Non-ducted, 3.5 to 4.5 tons87.4(50 is the typical model of its size class) (higher)MCY-MAP0487HS-UL*17 of 17 models have all five ratings · AHRI 21335025018.2(50 is the typical model of its size class)ASH542JCDD**2 of 2 models have all five ratings · AHRI 210532846
Non-ducted, 5 tons and up87.3(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 1 models have all five ratings · AHRI 213350252No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierGE Appliances
COP at 5°Fbeats 100% · 2.70MCY-MAP0367HS-UL*Non-ducted, 2.5 to 3 tonsbeats 99% · 2.99NS17H48SA4-**ADucted, 3.5 to 4.5 tons
Capacity retention at 5°Fbeats 100% · 160%WDLCURAH18ABKDucted, up to 1.5 tonsbeats 96% · 117%ASH112URDE**Non-ducted, up to 1.5 tons
HSPF2beats 100% · 15.038MPRBQ09AA3Also sold as Arcoaire DLCPRBH09AAKNon-ducted, up to 1.5 tonsbeats 99% · 14.0ASH109URDSE*Non-ducted, up to 1.5 tons
SEER2beats 100% · 23.1MCY-MAP0607HS-UL*Non-ducted, 5 tons and upbeats 100% · 30.0ASH109URDSE*Non-ducted, up to 1.5 tons
EER2beats 100% · 13.025VNA460A*031*Ducted, 5 tons and upbeats 100% · 14.5NS17H18SA4-**ADucted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 96,220 Btu/h38MURAQ60AB3*Also sold as Grandaire WDLCURAH60ABKDucted, 3.5 to 4.5 tonsbeats 96% · 20,000 Btu/hASH118URDE**Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Carrier vs GE Appliances: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Carrier (median, middle 50%)
  • GE Appliances (median, middle 50%)
Heating capacity, % of its 47°F maximum63%72%COP at maximum capacity1.971.80

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
Carrier: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F87100%100%100%100%100%
Carrier, 17°F8763%67%72%79%86%
Carrier, 5°F8755%57%63%71%78%
Carrier: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F872.642.833.063.283.51
Carrier, 17°F871.892.042.172.32.53
Carrier, 5°F871.81.91.972.062.17
GE Appliances: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
GE Appliances, 47°F27100%100%100%100%100%
GE Appliances, 17°F2764%65%67%79%87%
GE Appliances, 5°F2754%63%72%80%87%
GE Appliances: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
GE Appliances, 47°F272.933.183.43.74.2
GE Appliances, 17°F272.192.32.492.642.84
GE Appliances, 5°F271.81.81.822.31

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter