Skip to content

Carrier vs GE Appliances heat pumps

Measured against models of the same size and duct type, Carrier and GE Appliances split the 6 ratings 3–3. Carrier has 816 outdoor models, GE Appliances has 88 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and GE Appliances on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Carrier and GE Appliances split the 6 ratings 3–3.
  • Carrier
  • GE Appliances
  • Other ranked manufacturers
CarrierGE Appli…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierGE Appliances
Efficiency index48% (higher)median — · 23rd ranked43% (higher)median — · 27th ranked
COP at 5°F56% (higher)median 2.04 · 16th ranked40% (higher)median 1.80 · 28th ranked
Capacity retention at 5°F34%median 53% · 28th ranked42%median 61% · 25th ranked
HSPF240%median 7.8 · 25th ranked48%median 8.1 · 17th ranked
SEER242% (higher)median 15.2 · 23rd ranked39% (higher)median 15.2 · 27th ranked
EER259% (higher)median 11.5 · 8th ranked46% (higher)median 11.5 · 21st ranked
Heating capacity at 5°F37%median 18,600 Btu/h · 27th ranked44%median 19,000 Btu/h · 24th ranked
Outdoor models81688
AHRI certifications521,4039,036

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierGE Appliances
CEE 2025 Tier 1 (Split ASHP)40.2%328 models46.6%41 models
CEE 2026 Tier 1 (Split ASHP)35.3%288 models44.3%39 models
CEE Advanced Tier (Split ASHP)1%8 models5.7%5 models
Xcel Energy Colorado cold-climate ASHP (2025)27.2%222 models40.9%36 models
DOE Cold Climate Heat Pump Challenge1%8 models5.7%5 models
ENERGY STAR Cold Climate26.7%218 models38.6%34 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 10 groups where both have models
  • Carrier
  • GE Appliances
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierGE Appliances
Ducted, up to 1.5 tons69 · index 56%10 · index 51%
Ducted, 2 tons93 · index 47%11 · index 45%
Ducted, 2.5–3 tons228 · index 45%24 · index 36%
Ducted, 3.5–4.5 tons306 · index 44%28 · index 42%
Ducted, 5 tons and up68 · index 50%8 · index 37%
Non-ducted, up to 1.5 tons54 · index 59%14 · index 47%
Non-ducted, 2 tons16 · index 57%5 · index 49%
Non-ducted, 2.5–3 tons30 · index 55%5 · index 44%
Non-ducted, 3.5–4.5 tons22 · index 47%2 · index 50%
Non-ducted, 5 tons and up4 · index 57%1 · index 68%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelGE AppliancesCold-climate score, best model
Ducted, up to 1.5 tons93.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK30 of 68 models qualify · AHRI 21532379870.7(50 is the typical model of its size class)NS15H18HA5***with ducted air handler D(A,C,E)30B3J+TDR9 of 10 models qualify · AHRI 218358333
Ducted, 2 tons85.7(50 is the typical model of its size class)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK44 of 94 models qualify · AHRI 21532381789.1(50 is the typical model of its size class) (higher)NS21H24MA5-**Awith indoor coil D(A,C,E)24C3Z+TXV+TDR and furnace NF96U070S3B7 of 12 models qualify · AHRI 218792657
Ducted, 2.5–3 tons83.2(50 is the typical model of its size class)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK59 of 229 models qualify · AHRI 21535711988.0(50 is the typical model of its size class) (higher)NS21H36MA5-**Awith indoor coil D(A,C,E)36C3Z+TXV+TDR and furnace NF80U045S3A8 of 22 models qualify · AHRI 218792658
Ducted, 3.5–4.5 tons89.7(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A63 of 293 models qualify · AHRI 21837271487.5(50 is the typical model of its size class)NS21H48MA5-**Awith indoor coil D(A,C,E)48D4Z+TXV+TDR and furnace NF80U110S5C9 of 29 models qualify · AHRI 218792661
Ducted, 5 tons and up94.7(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL19 of 80 models qualify · AHRI 21676324980.9(50 is the typical model of its size class)MWHQ060NC2AA*1 of 8 models qualify · AHRI 218325038
Non-ducted, up to 1.5 tons96.8(50 is the typical model of its size class) (higher)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK35 of 54 models qualify · AHRI 21541321464.1(50 is the typical model of its size class)1G12ED2BE**with ductless indoor unit GS12WP2BE14 of 14 models qualify · AHRI 215876552
Non-ducted, 2 tons89.4(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK15 of 16 models qualify · AHRI 21532381561.9(50 is the typical model of its size class)3G24ED2BE**4 of 5 models qualify · AHRI 217009765
Non-ducted, 2.5–3 tons89.4(50 is the typical model of its size class) (higher)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK21 of 30 models qualify · AHRI 21532384373.8(50 is the typical model of its size class)MWHQ036NC2AA*4 of 5 models qualify · AHRI 218309294
Non-ducted, 3.5–4.5 tons79.4(50 is the typical model of its size class) (higher)RAV-BP421AT2P-ULwith ductless indoor unit RAV-HB421CTP-UL18 of 22 models qualify · AHRI 21641547267.0(50 is the typical model of its size class)MWHQ048NC2AA*2 of 2 models qualify · AHRI 218309297
Non-ducted, 5 tons and up50.6(50 is the typical model of its size class)37VMB060HDS3-11 of 4 models qualify · AHRI 21636971464.1(50 is the typical model of its size class) (higher)MWHQ060NC2AA*1 of 1 models qualify · AHRI 218325037

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelGE AppliancesAll-around score, best model
Ducted, up to 1.5 tons95.6(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK64 of 68 models have all five ratings · AHRI 21532379866.0(50 is the typical model of its size class)1G09ED2BE**with ducted air handler US09MB2BE10 of 10 models have all five ratings · AHRI 217036500
Ducted, 2 tons82.9(50 is the typical model of its size class)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA90 of 90 models have all five ratings · AHRI 21762425284.9(50 is the typical model of its size class) (higher)NS21H24MA5-**Awith indoor coil D(A,C,E)24C3Z+TXV+TDR and furnace NF96U070S3B11 of 11 models have all five ratings · AHRI 218792657
Ducted, 2.5–3 tons88.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL209 of 230 models have all five ratings · AHRI 21641547779.8(50 is the typical model of its size class)NS21H36MA5-**Awith ducted air handler NAM42V1TA5*-23 of 23 models have all five ratings · AHRI 217642528
Ducted, 3.5–4.5 tons90.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA241 of 275 models have all five ratings · AHRI 21558791785.2(50 is the typical model of its size class)NS21H48MA5-**Awith indoor coil D(A,C,E)48D4Z+TXV+TDR and furnace NF80U110S5C28 of 28 models have all five ratings · AHRI 218792661
Ducted, 5 tons and up89.1(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA81 of 101 models have all five ratings · AHRI 21593148474.6(50 is the typical model of its size class)MWHQ060NC2AA*9 of 9 models have all five ratings · AHRI 218325038
Non-ducted, up to 1.5 tons96.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK51 of 54 models have all five ratings · AHRI 21532374270.4(50 is the typical model of its size class)1G09ED2BE**with ductless indoor unit GS09WP2BE14 of 14 models have all five ratings · AHRI 215876551
Non-ducted, 2 tons88.5(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK15 of 16 models have all five ratings · AHRI 21532375267.2(50 is the typical model of its size class)3G24ED2BE**5 of 5 models have all five ratings · AHRI 217009765
Non-ducted, 2.5–3 tons91.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL29 of 30 models have all five ratings · AHRI 21641546576.2(50 is the typical model of its size class)MWHQ036NC2AA*5 of 5 models have all five ratings · AHRI 218309294
Non-ducted, 3.5–4.5 tons84.9(50 is the typical model of its size class) (higher)MCY-MUB0488HS2P-UL20 of 22 models have all five ratings · AHRI 21676028873.8(50 is the typical model of its size class)MWHQ048NC2AA*2 of 2 models have all five ratings · AHRI 218309297
Non-ducted, 5 tons and up69.0(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL4 of 4 models have all five ratings · AHRI 21676325167.9(50 is the typical model of its size class)MWHQ060NC2AA*1 of 1 models have all five ratings · AHRI 218325037

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierGE Appliances
COP at 5°Fbeats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5–4.5 tonsbeats 100% · 4.00NS21H36MA5-**ADucted, 2.5–3 tons
Capacity retention at 5°Fbeats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 98% · 109%NS21H24MA5-**ADucted, 2 tons
HSPF2beats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 13.5MWHQ036NC2AA*Ducted, 2.5–3 tons
SEER2beats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 99% · 20.5NS21H60MA5-**ADucted, 3.5–4.5 tons
EER2beats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5–3 tonsbeats 99% · 13.5NS16H42SA5-**ADucted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5–4.5 tonsbeats 99% · 20,000 Btu/h2G20ED2BE**Ducted, up to 1.5 tons

More comparisons