Skip to content

CLASSIC vs HAIER: heat pump ratings compared

Against heat pumps of the same size and type, a typical CLASSIC model beats 49% and a typical HAIER model 45%. CLASSIC rates slightly higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

CLASSIC

49%

of similar heat pumps beaten by its typical model

About average

32 models listed

HAIER

45%

of similar heat pumps beaten by its typical model

Below average

53 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCLASSIC: Beats 38%HAIER: Beats 34%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCLASSIC: Beats 41%HAIER: Beats 48%
  • Winter-long heating efficiencyHSPF2CLASSIC: Beats 51%HAIER: Beats 57%
  • Summer-long cooling efficiencySEER2CLASSIC: Beats 52%HAIER: Beats 47%
  • Hot-day cooling efficiencyEER2CLASSIC: Beats 49%HAIER: Beats 40%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    CLASSIC
    66%
    HAIER
    49%
  • Xcel CC

    CLASSIC
    44%
    HAIER
    42%
  • CEE Advanced

    CLASSIC
    0%
    HAIER
    8%
  • ENERGY STAR CC

    CLASSIC
    13%
    HAIER
    30%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

CLASSIC

  1. 1MMRSHC27AS3CLASSIC2.5 tons · 28,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    75.4score / 100Heating 65 · Cooling 86
  2. 2MMRSHC36AS4CLASSIC3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 64% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    65% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.68 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    56.6score / 100Heating 44 · Cooling 69
  3. 3MRSVHC36ASwith ducted air handler MFCHC36SCLASSIC3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 55% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.91 (COP at 5°F)
    Good
    Winter efficiency
    8.8 (HSPF2)
    Good
    Cooling efficiency
    15.8 (SEER2)
    Below the middle
    Hot-day cooling
    8.8 (EER2)
    Below the middle
    37.7score / 100Heating 48 · Cooling 28

HAIER

  1. 14U36EH2HD**HAIER3 tons · 33,000 Btu/h · DuctedCold-climate pick, score 61.9Meets ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    8.7 (HSPF2)
    Good
    Cooling efficiency
    15.7 (SEER2)
    Below the middle
    Hot-day cooling
    8.8 (EER2)
    Below the middle
    44.4score / 100Heating 62 · Cooling 27
  2. 21U3036LP2HD**with ducted air handler USYM30UCDDHAIER2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 54.0Meets ENERGY STAR CC
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    9.0 (EER2)
    Below the middle
    38.0score / 100Heating 54 · Cooling 22
  3. 3MVHP036MV2AAHAIER3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 50% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    50% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.4 (HSPF2)
    Good
    Cooling efficiency
    15.5 (SEER2)
    Below the middle
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    34.9score / 100Heating 33 · Cooling 37

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.