CLASSIC vs KERR: heat pump ratings compared

Against heat pumps of the same size and type, a typical CLASSIC model beats 49% and a typical KERR model 67%. KERR rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

CLASSIC

49%

of similar heat pumps beaten by its typical model

About average

32 models listed

KERR

67%

of similar heat pumps beaten by its typical model

Well above average

24 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCLASSIC: Beats 38%KERR: Beats 50%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCLASSIC: Beats 41%KERR: Beats 78%
  • Winter-long heating efficiencyHSPF2CLASSIC: Beats 51%KERR: Beats 76%
  • Summer-long cooling efficiencySEER2CLASSIC: Beats 52%KERR: Beats 68%
  • Hot-day cooling efficiencyEER2CLASSIC: Beats 49%KERR: Beats 58%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    CLASSIC
    66%
    KERR
    83%
  • Xcel CC

    CLASSIC
    44%
    KERR
    79%
  • CEE Advanced

    CLASSIC
    0%
    KERR
    8%
  • ENERGY STAR CC

    CLASSIC
    13%
    KERR
    88%

Top cold-climate picks, ducted 3.5 to 4.5 tons

CLASSIC

None of CLASSIC’s ducted, 3.5 to 4.5 tons models qualifies.

KERR

  1. 1A-KMH48PV-1KERR4 tons · 47,000 Btu/h · DuctedKeeps 87% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    87% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Seasonal efficiency
    9.0 (HSPF2)
    Good
    75.1score / 100
  2. 2A-KCD48SA-1with ducted air handler B-VCD48SA-1KERR4 tons · 47,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets ENERGY STAR CC
    Heat kept at 5°F
    92% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    9.4 (HSPF2)
    Great
    74.0score / 100
  3. 3A-KCD60SA-1with ducted air handler B-KCD60SA-1KERR4.5 tons · 55,000 Btu/h · DuctedKeeps 82% of its heat at 5°FMeets ENERGY STAR CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.91 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    9.4 (HSPF2)
    Great
    71.7score / 100

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.