Skip to content

COMFORTSTAR vs Mitsubishi Electric: heat pump ratings compared

Against heat pumps of the same size and type, a typical COMFORTSTAR model beats 47% and a typical Mitsubishi Electric model 65%. Mitsubishi Electric rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

COMFORTSTAR

47%

of similar heat pumps beaten by its typical model

About average

124 models listed

Mitsubishi Electric

65%

of similar heat pumps beaten by its typical model

Well above average

400 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCOMFORTSTAR: Beats 46%Mitsubishi Electric: Beats 68%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCOMFORTSTAR: Beats 44%Mitsubishi Electric: Beats 54%
  • Winter-long heating efficiencyHSPF2COMFORTSTAR: Beats 48%Mitsubishi Electric: Beats 71%
  • Summer-long cooling efficiencySEER2COMFORTSTAR: Beats 43%Mitsubishi Electric: Beats 63%
  • Hot-day cooling efficiencyEER2COMFORTSTAR: Beats 42%Mitsubishi Electric: Beats 64%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    COMFORTSTAR
    39%
    Mitsubishi Electric
    65%
  • Xcel CC

    COMFORTSTAR
    26%
    Mitsubishi Electric
    52%
  • CEE Advanced

    COMFORTSTAR
    1%
    Mitsubishi Electric
    6%
  • ENERGY STAR CC

    COMFORTSTAR
    21%
    Mitsubishi Electric
    36%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

COMFORTSTAR

  1. 1CMZ-27-3ZCOMFORTSTAR2.5 tons · 28,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    75.4score / 100Heating 65 · Cooling 86
  2. 2CVH-27-3SHCOMFORTSTAR2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 66.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    74.7score / 100Heating 67 · Cooling 83
  3. 3CVH-36-4SHCOMFORTSTAR3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 64.0Meets none of the standards tracked here
    Heat kept at 5°F
    89% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.70 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Good
    71.4score / 100Heating 64 · Cooling 79

Mitsubishi Electric

  1. 1PUZ-HA36NKA1***with ducted air handler PVA-A36AAMitsubishi ElectricAlso sold as Trane / Mitsubishi Electric PUZ-HA36NKA, Trane / Mitsubishi Electric TRUZH0361KA00, Trane / Mitsubishi Electric TRUZH0361KA00NA, Trane / Mitsubishi Electric TRUZH0361KA103 tons · 33,000 Btu/h · DuctedCold-climate pick, score 84.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    95% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    18.2 (SEER2)
    Great
    Hot-day cooling
    13.2 (EER2)
    Top 10%
    87.2score / 100Heating 85 · Cooling 90
  2. 2PUZ-HA36NKA*with ducted air handler PEAD-A36AA9Mitsubishi ElectricAlso sold as Trane / Mitsubishi Electric TRUZH0361KA3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 82.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    95% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.01 (COP at 5°F)
    Good
    Winter efficiency
    9.3 (HSPF2)
    Great
    Cooling efficiency
    17.6 (SEER2)
    Great
    Hot-day cooling
    12.7 (EER2)
    Top 10%
    84.3score / 100Heating 82 · Cooling 87
  3. 3PUZ-HA30NKA1***with ducted air handler PVA-A30AAMitsubishi ElectricAlso sold as Trane / Mitsubishi Electric TRUZH0301KA00, Trane / Mitsubishi Electric TRUZH0301KA00NA2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 78.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    94% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.17 (COP at 5°F)
    Great
    Winter efficiency
    8.7 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    83.5score / 100Heating 79 · Cooling 88

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter