Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Cooper&Hunter vs LPS Legacy heat pumps
Measured against models of the same size and duct type, Cooper&Hunter scores higher on 6 of the 6 ratings. Cooper&Hunter has 57 outdoor models, LPS Legacy has 58 outdoor models. LPS Legacy has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Cooper&Hunter
- LPS Legacy
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Cooper&Hunter | LPS Legacy |
|---|---|---|
| Efficiency index | 57% (higher)median — · 11th ranked | 53% (higher)median — |
| COP at 5°F | 55% (higher)median 2.00 · 13th ranked | 51% (higher)median 1.97 |
| Capacity retention at 5°F | 56% (higher)median 70% · 12th ranked | 49% (higher)median 67% |
| HSPF2 | 64% (higher)median 9.4 · 8th ranked | 62% (higher)median 9.2 |
| SEER2 | 56% (higher)median 19.8 · 10th ranked | 55% (higher)median 18.5 |
| EER2 | 45% (higher)median 10.5 · 22nd ranked | 42% (higher)median 10.6 |
| Heating capacity at 5°F | 53% (higher)median 17,500 Btu/h · 15th ranked | 50% (higher)median 19,000 Btu/h |
| Outdoor models | 57 | 58 |
| AHRI certifications | 408 | 146 |
Share of models meeting each standard
| Standard | Cooper&Hunter | LPS Legacy |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 57.9%33 models | 58.6%34 models |
| CEE 2026 Tier 1 (Split ASHP) | 56.1%32 models | 55.2%32 models |
| CEE Advanced Tier (Split ASHP) | 1.8%1 models | 3.4%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 45.6%26 models | 39.7%23 models |
| DOE Cold Climate Heat Pump Challenge | 1.8%1 models | 3.4%2 models |
| ENERGY STAR Cold Climate | 42.1%24 models | 43.1%25 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Cooper&Hunter
- LPS Legacy
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Cooper&Hunter | LPS Legacy |
|---|---|---|
| Ducted, up to 1.5 tons | 8 · index 67% | 6 · index 61% |
| Ducted, 2 tons | 2 · index 82% | 4 · index 65% |
| Ducted, 2.5–3 tons | 10 · index 56% | 13 · index 53% |
| Ducted, 3.5–4.5 tons | 10 · index 58% | 8 · index 54% |
| Ducted, 5 tons and up | 3 · index 55% | 3 · index 51% |
| Non-ducted, up to 1.5 tons | 24 · index 56% | 20 · index 53% |
| Non-ducted, 2 tons | 5 · index 47% | 4 · index 47% |
| Non-ducted, 2.5–3 tons | 13 · index 59% | 13 · index 47% |
| Non-ducted, 3.5–4.5 tons | 11 · index 49% | 7 · index 46% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | Cooper&HunterCold-climate score, best model | LPS LegacyCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 74.9(50 is the typical model of its size class)CH-HPR09-230VOwith ducted air handler CH-M09DTUI7 of 8 models qualify · AHRI 207742328 | 81.3(50 is the typical model of its size class) (higher)DLCSRBH18AAKwith ducted air handler DLFSDAH18XHK5 of 6 models qualify · AHRI 211756586 |
| Ducted, 2 tons | 80.3(50 is the typical model of its size class) (higher)CH-ES24-230VOwith ducted air handler CH-M24DTUI2 of 2 models qualify · AHRI 207742325 | 79.4(50 is the typical model of its size class)DLCSRBH24AAKwith ducted air handler DLFSDAH24XAK4 of 4 models qualify · AHRI 211756579 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class) (higher)CH-HYP36LCUOwith ducted air handler CH-36LCDTU/IAlso listed as CH-NHPR36LCU-230VO4 of 10 models qualify · AHRI 205901586 | 78.6(50 is the typical model of its size class)DLCURAH36ABKwith ducted air handler DLFULAH36XCX + CI3 of 13 models qualify · AHRI 213372201 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class) (higher)CH-HYP48LCUOwith ducted air handler CH-48LCDTU/IAlso listed as CH-NHPR48LCU-230VO5 of 10 models qualify · AHRI 205263864 | 74.9(50 is the typical model of its size class)DLCURAH48ABKwith ducted air handler DLFUAAH60XAK4 of 8 models qualify · AHRI 217197708 |
| Ducted, 5 tons and up | None on this board (0 of 3 models qualify) | None on this board (0 of 3 models qualify) |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)CH-HPR06F9-230VOwith ductless indoor unit CH-06MASTWM-230VI14 of 24 models qualify · AHRI 207740500 | 95.0(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAK11 of 20 models qualify · AHRI 211756581 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class)CH-HPR24-230VOwith ductless indoor unit CH-N24MSPHCT-230VI3 of 5 models qualify · AHRI 207742335 | 86.1(50 is the typical model of its size class)DLCSRBH24AAKwith ductless indoor unit DLFSCBH24XAK2 of 4 models qualify · AHRI 211756560 |
| Non-ducted, 2.5–3 tons | 79.3(50 is the typical model of its size class) (higher)CH-HPR36M-230VO4 of 13 models qualify · AHRI 207742379 | 73.4(50 is the typical model of its size class)DLCMHBH36DAK2 of 13 models qualify · AHRI 211756577 |
| Non-ducted, 3.5–4.5 tons | 76.8(50 is the typical model of its size class)CH-NHPR60LCU-230VOwith ductless indoor unit CH-60LCFC/I5 of 11 models qualify · AHRI 211246027 | 80.5(50 is the typical model of its size class) (higher)DLCMHBH48EAK3 of 7 models qualify · AHRI 211756575 |
All-around best
| Size and duct type | Cooper&HunterAll-around score, best model | LPS LegacyAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.2(50 is the typical model of its size class)CH-HPR09-230VOwith ducted air handler CH-M09DTUI8 of 8 models have all five ratings · AHRI 207742328 | 85.2(50 is the typical model of its size class)DLCSRBH09AAKwith ducted air handler DLFSDAH09XAK6 of 6 models have all five ratings · AHRI 211756568 |
| Ducted, 2 tons | 83.8(50 is the typical model of its size class) (higher)CH-ES24-230VOwith ducted air handler CH-M24DTUI2 of 2 models have all five ratings · AHRI 207742325 | 80.1(50 is the typical model of its size class)DLCSRBH24AAKwith ducted air handler DLFSDAH24XAK4 of 4 models have all five ratings · AHRI 211756579 |
| Ducted, 2.5–3 tons | 75.4(50 is the typical model of its size class) (higher)CH-28MES-230VO8 of 10 models have all five ratings · AHRI 207742365 | 72.0(50 is the typical model of its size class)DLCMHBH30DAK12 of 13 models have all five ratings · AHRI 211756500 |
| Ducted, 3.5–4.5 tons | 82.0(50 is the typical model of its size class)CH-HPR48M-230VO8 of 10 models have all five ratings · AHRI 207742382 | 82.0(50 is the typical model of its size class)DLCMHBH48EAK7 of 8 models have all five ratings · AHRI 211756576 |
| Ducted, 5 tons and up | 57.1(50 is the typical model of its size class)CH-N60LCU-230VOwith ducted air handler CH-60LCDTU/I3 of 3 models have all five ratings · AHRI 207742344 | 57.1(50 is the typical model of its size class)DLCLRCH58AAKwith ducted air handler DLFLDAH58XHK3 of 3 models have all five ratings · AHRI 211756477 |
| Non-ducted, up to 1.5 tons | 92.0(50 is the typical model of its size class)CH-HPR06F9-230VOwith ductless indoor unit CH-06MASTWM-230VI24 of 24 models have all five ratings · AHRI 207740500 | 93.6(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAK20 of 20 models have all five ratings · AHRI 211756581 |
| Non-ducted, 2 tons | 84.3(50 is the typical model of its size class)CH-HPR24-230VOwith ductless indoor unit CH-24MASTWM-230VI5 of 5 models have all five ratings · AHRI 207740504 | 84.3(50 is the typical model of its size class)DLCSRBH24AAKwith ductless indoor unit DLFSHCH24XAK4 of 4 models have all five ratings · AHRI 211756584 |
| Non-ducted, 2.5–3 tons | 82.8(50 is the typical model of its size class) (higher)CH-HPR36M-230VO9 of 13 models have all five ratings · AHRI 207742379 | 70.8(50 is the typical model of its size class)DLCMHBH36DAK11 of 13 models have all five ratings · AHRI 211756577 |
| Non-ducted, 3.5–4.5 tons | 77.9(50 is the typical model of its size class) (higher)CH-HPR48M-230VO8 of 11 models have all five ratings · AHRI 207742381 | 73.8(50 is the typical model of its size class)DLCMHBH48EAK5 of 7 models have all five ratings · AHRI 211756575 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Cooper&Hunter | LPS Legacy |
|---|---|---|
| COP at 5°F | beats 98% · 2.45CH-ES12-230VONon-ducted, up to 1.5 tons | beats 99% · 2.89DLCPRBH18AAKNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 97% · 97%CH-NHPR48LCU-230VODucted, 3.5–4.5 tons | beats 97% · 120%DLCPRBH18AAKNon-ducted, up to 1.5 tons |
| HSPF2 | beats 99% · 10.3CH-HYP48LCUOAlso listed as CH-NHPR48LCU-230VODucted, 3.5–4.5 tons | beats 100% · 15.0DLCPRBH09AAKNon-ducted, up to 1.5 tons |
| SEER2 | beats 99% · 24.6CH-28MES-230VONon-ducted, 2.5–3 tons | beats 99% · 20.9DLCMHBH48EAKDucted, 3.5–4.5 tons |
| EER2 | beats 98% · 16.2CH-HPR09-230VONon-ducted, up to 1.5 tons | beats 98% · 16.2DLCSRBH09AAKNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 100% · 57,600 Btu/hCH-NHPR60LCU-230VODucted, 3.5–4.5 tons | beats 100% · 24,000 Btu/hDLCPRBH18AAKNon-ducted, up to 1.5 tons |