Both views use the same certified data. This device remembers your choice.
Cooper&Hunter vs MOOVAIR: heat pump ratings compared
Against heat pumps of the same size and type, a typical Cooper&Hunter model beats 58% and a typical MOOVAIR model 62%. MOOVAIR rates slightly higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
Cooper&Hunter
58%
of similar heat pumps beaten by its typical model
Above average57 models listed
MOOVAIR
62%
of similar heat pumps beaten by its typical model
Well above average55 models listed
- Efficiency on a 5°F dayCOP at 5°FCooper&Hunter: Beats 56%MOOVAIR: Beats 52%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCooper&Hunter: Beats 57%MOOVAIR: Beats 66%
- Winter-long heating efficiencyHSPF2Cooper&Hunter: Beats 64%MOOVAIR: Beats 74%
- Summer-long cooling efficiencySEER2Cooper&Hunter: Beats 56%MOOVAIR: Beats 63%
- Hot-day cooling efficiencyEER2Cooper&Hunter: Beats 45%MOOVAIR: Beats 50%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Cooper&Hunter
- 58%
- MOOVAIR
- 67%
Xcel CC
- Cooper&Hunter
- 46%
- MOOVAIR
- 55%
CEE Advanced
- Cooper&Hunter
- 2%
- MOOVAIR
- 4%
ENERGY STAR CC
- Cooper&Hunter
- 42%
- MOOVAIR
- 62%
Top cold-climate picks, ductless 2.5 to 3 tons
Showing Ductless, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling). What size is my system?
Cooper&Hunter
- 1CH-HPR36M-230VOCooper&Hunter (sold as C&H)3 tons · 36,000 Btu/h · DuctlessKeeps 97% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 97% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.3 (HSPF2)
- Great
- 2CH-NHPR36LCU-230VOwith ductless indoor unit CH-N36LCCT-230VICooper&Hunter (sold as C&H)3 tons · 36,000 Btu/h · DuctlessKeeps 103% of its heat at 5°FMeets Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 103% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.83 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 3CH-HPR35-230VOwith ductless indoor unit CH-35HASTWM-230VICooper&Hunter3 tons · 33,000 Btu/h · DuctlessKeeps 99% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 99% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
MOOVAIR
- 1DMA36HOM25230X3MOOVAIR3 tons · 36,000 Btu/h · DuctlessKeeps 97% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 97% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.3 (HSPF2)
- Great
- 2DMA36HOS28230E8with ductless indoor unit DUA36HICU230X5MOOVAIR3 tons · 36,000 Btu/h · DuctlessKeeps 103% of its heat at 5°FMeets Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 103% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.83 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 3DMA27HOM25230X3MOOVAIR2.5 tons · 28,000 Btu/h · DuctlessKeeps 89% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 89% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.6 (HSPF2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view