Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Della vs DUOHOME heat pumps
Measured against models of the same size and duct type, DUOHOME scores higher on 6 of the 6 ratings. Della has 22 outdoor models, DUOHOME has 22 outdoor models. DUOHOME has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Della
- DUOHOME
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Della | DUOHOME |
|---|---|---|
| Efficiency index | 39%median — · 27th ranked | 52%median — |
| COP at 5°F | 42%median 1.80 · 25th ranked | 51%median 1.99 |
| Capacity retention at 5°F | 37%median 70% · 26th ranked | 38%median 66% |
| HSPF2 | 23%median 8.5 · 27th ranked | 61%median 9.3 |
| SEER2 | 35%median 19.0 · 27th ranked | 57%median 20.0 |
| EER2 | 28%median 10.0 · 27th ranked | 44%median 10.7 |
| Heating capacity at 5°F | 37%median 11,600 Btu/h · 26th ranked | 43%median 14,800 Btu/h |
| Outdoor models | 22 | 22 |
| AHRI certifications | 22 | 37 |
Share of models meeting each standard
| Standard | Della | DUOHOME |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 54.5%12 models | 59.1%13 models |
| CEE 2026 Tier 1 (Split ASHP) | 45.5%10 models | 50%11 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 36.4%8 models | 27.3%6 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 18.2%4 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Della
- DUOHOME
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Della | DUOHOME |
|---|---|---|
| Ducted, up to 1.5 tons | None | 2 · index 69% |
| Ducted, 2 tons | None | 1 · index 84% |
| Ducted, 2.5–3 tons | None | 4 · index 55% |
| Ducted, 3.5–4.5 tons | None | 4 · index 53% |
| Ducted, 5 tons and up | None | 1 · index 55% |
| Non-ducted, up to 1.5 tons | 16 · index 43% | 9 · index 49% |
| Non-ducted, 2 tons | 3 · index 39% | 2 · index 47% |
| Non-ducted, 2.5–3 tons | 3 · index 27% | 5 · index 49% |
| Non-ducted, 3.5–4.5 tons | None | 3 · index 43% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | DellaCold-climate score, best model | DUOHOMECold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 52.0(50 is the typical model of its size class)D2OA-18HFN1-M1 of 2 models qualify · AHRI 211911389 |
| Ducted, 2 tons | No models in this size class | 80.3(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ducted air handler DTIU-24HWFN1-M1 of 1 models qualify · AHRI 214797741 |
| Ducted, 2.5–3 tons | No models in this size class | 57.8(50 is the typical model of its size class)D3OJ-27HFN1-M1 of 4 models qualify · AHRI 211911392 |
| Ducted, 3.5–4.5 tons | No models in this size class | None on this board (0 of 4 models qualify) |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 68.8(50 is the typical model of its size class) (higher)048-TP-12K2V-23S-OUTwith ductless indoor unit 048-TP-12K2V-23S-IN8 of 16 models qualify · AHRI 213927343 | 63.3(50 is the typical model of its size class)DOX230-09HFN1-MW5Wwith ductless indoor unit DCA3U-09HRFN1-M(C)3 of 9 models qualify · AHRI 214875723 |
| Non-ducted, 2 tons | None on this board (0 of 3 models qualify) | 59.4(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ductless indoor unit DCD1-24HRFN1-MT0W(GA)1 of 2 models qualify · AHRI 214875724 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 3 models qualify) | 50.1(50 is the typical model of its size class)D3OJ-27HFN1-M1 of 5 models qualify · AHRI 211911391 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | None on this board (0 of 3 models qualify) |
All-around best
| Size and duct type | DellaAll-around score, best model | DUOHOMEAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 78.5(50 is the typical model of its size class)DOX430-18HFN1-MU0Wwith ducted air handler DTIU-18HWFN1-M2 of 2 models have all five ratings · AHRI 214797740 |
| Ducted, 2 tons | No models in this size class | 83.8(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ducted air handler DTIU-24HWFN1-M1 of 1 models have all five ratings · AHRI 214797741 |
| Ducted, 2.5–3 tons | No models in this size class | 71.7(50 is the typical model of its size class)D3OJ-27HFN1-M3 of 4 models have all five ratings · AHRI 211911392 |
| Ducted, 3.5–4.5 tons | No models in this size class | 63.5(50 is the typical model of its size class)D5OG-48HFN1-M3 of 4 models have all five ratings · AHRI 211911398 |
| Ducted, 5 tons and up | No models in this size class | 54.5(50 is the typical model of its size class)DOE30U-60HFN1-Mwith ducted air handler DHG-60HWFN1-MW1 of 1 models have all five ratings · AHRI 206314613 |
| Non-ducted, up to 1.5 tons | 70.8(50 is the typical model of its size class)048-TP-12K2V-23S-OUTwith ductless indoor unit 048-TP-12K2V-23S-IN10 of 16 models have all five ratings · AHRI 213927343 | 71.6(50 is the typical model of its size class) (higher)DOX230-12HFN1-MV5Wwith ductless indoor unit DCA3U-12HRFN1-M(C)9 of 9 models have all five ratings · AHRI 214875728 |
| Non-ducted, 2 tons | 53.0(50 is the typical model of its size class)048-TP-24K2V-20S-OUTwith ductless indoor unit 048-TP-24K2V-20S-IN2 of 3 models have all five ratings · AHRI 213927345 | 66.3(50 is the typical model of its size class) (higher)DOD33-24HFN1-MT0Wwith ductless indoor unit DCD1-24HRFN1-MT0W(GA)2 of 2 models have all five ratings · AHRI 214875724 |
| Non-ducted, 2.5–3 tons | 29.5(50 is the typical model of its size class)048-TL-36K-MODU3 of 3 models have all five ratings · AHRI 211042067 | 67.1(50 is the typical model of its size class) (higher)D3OJ-27HFN1-M4 of 5 models have all five ratings · AHRI 211911391 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 48.3(50 is the typical model of its size class)D5OG-48HFN1-M3 of 3 models have all five ratings · AHRI 211911397 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Della | DUOHOME |
|---|---|---|
| COP at 5°F | beats 89% · 2.21048-TP-18K2V-22S-OUTNon-ducted, up to 1.5 tons | beats 92% · 2.28DOX230-12HFN1-MV5WNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 64% · 77%048-TP-9K2V-23S-OUTNon-ducted, up to 1.5 tons | beats 73% · 59%DOE30U-60HFN1-MDucted, 5 tons and up |
| HSPF2 | beats 57% · 9.5048-TP-12K2V-23S-OUTNon-ducted, up to 1.5 tons | beats 98% · 11.2DOD33-24HFN1-MT0WDucted, 2 tons |
| SEER2 | beats 79% · 23.5048-TP-9K2V-23S-OUTNon-ducted, up to 1.5 tons | beats 98% · 21.0D3OJ-27HFN1-MDucted, 2.5–3 tons |
| EER2 | beats 68% · 13.0048-TP-9K2V-23S-OUTNon-ducted, up to 1.5 tons | beats 85% · 12.5DOD33-24HFN1-MT0WDucted, 2 tons |
| Heating capacity at 5°F | beats 78% · 13,000 Btu/h048-TL-18K-MODUNon-ducted, up to 1.5 tons | beats 78% · 35,600 Btu/hDOE30U-60HFN1-MDucted, 5 tons and up |