Both views use the same certified data. This device remembers your choice.
Della vs DUOHOME heat pumps
Measured against models of the same size and duct type, DUOHOME scores higher on 6 of the 6 ratings. Della has 97 outdoor models, DUOHOME has 50 outdoor models. DUOHOME has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Della
- DUOHOME
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Della | DUOHOME |
|---|---|---|
| Efficiency index | 49%median — · 22nd ranked | 58%median — |
| COP at 5°F | 43%median 1.90 · 26th ranked | 62%median 2.00 |
| Capacity retention at 5°F | 46%median 73% · 21st ranked | 50%median 72% |
| HSPF2 | 51%median 9.5 · 15th ranked | 62%median 9.4 |
| SEER2 | 57%median 21.0 · 11th ranked | 60%median 18.6 |
| EER2 | 42%median 11.2 · 23rd ranked | 51%median 11.7 |
| Heating capacity at 5°F | 47%median 12,000 Btu/h · 21st ranked | 58%median 24,000 Btu/h |
| Outdoor models | 97 | 50 |
| AHRI certifications | 149 | 85 |
Share of models meeting each standard
| Standard | Della | DUOHOME |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 68%66 models | 76%38 models |
| CEE 2026 Tier 1 (Split ASHP) | 68%66 models | 74%37 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 66%64 models | 66%33 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 42.3%41 models | 8%4 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Della
- DUOHOME
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Della | DUOHOME |
|---|---|---|
| Ducted, up to 1.5 tons | 6 · index 59% | 7 · index 72% |
| Ducted, 2 tons | 3 · index 49% | 7 · index 66% |
| Ducted, 2.5 to 3 tons | 6 · index 62% | 11 · index 58% |
| Ducted, 3.5 to 4.5 tons | 6 · index 54% | 12 · index 59% |
| Ducted, 5 tons and up | None | 3 · index 64% |
| Non-ducted, up to 1.5 tons | 63 · index 48% | 11 · index 55% |
| Non-ducted, 2 tons | 13 · index 48% | 5 · index 58% |
| Non-ducted, 2.5 to 3 tons | 12 · index 43% | 4 · index 48% |
| Non-ducted, 3.5 to 4.5 tons | 5 · index 44% | 3 · index 46% |
| Non-ducted, 5 tons and up | None | 2 · index 27% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | DellaCold-climate score, best model | DUOHOMECold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 59.9(50 is the typical model of its size class)048-TP-9K2V-24S-OUT6 of 6 models qualify · AHRI 218082833 | 81.7(50 is the typical model of its size class) (higher)DOX230-09HFN10-M1with ducted air handler DTJ-09HWFN10-M1-D5 of 7 models qualify · AHRI 218465653 |
| Ducted, 2 tons | 60.1(50 is the typical model of its size class)048-TP-23K2V-23S-OUT3 of 3 models qualify · AHRI 218082836 | 77.1(50 is the typical model of its size class) (higher)DOD30-24HFN10-M1with ducted air handler DTJ-24HWFN10-M1-D6 of 7 models qualify · AHRI 218465656 |
| Ducted, 2.5 to 3 tons | 63.0(50 is the typical model of its size class)048-TPH-MODU-1D46 of 6 models qualify · AHRI 218718740 | 73.1(50 is the typical model of its size class) (higher)DOX630-36HFN10-M3Xwith ducted air handler DVBC-36HWFN10-MC3E-D7 of 11 models qualify · AHRI 218465642 |
| Ducted, 3.5 to 4.5 tons | 63.7(50 is the typical model of its size class)048-TCQ-MODU-1D56 of 6 models qualify · AHRI 218718738 | 78.1(50 is the typical model of its size class) (higher)D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-D9 of 12 models qualify · AHRI 217956870 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 3 models qualify) |
| Non-ducted, up to 1.5 tons | 72.4(50 is the typical model of its size class)048-TPH-MODU-1D344 of 63 models qualify · AHRI 218471007 | 81.4(50 is the typical model of its size class) (higher)DOX230-09HFN10-M1with ductless indoor unit DCA4-09HRFN10-M1-D8 of 11 models qualify · AHRI 218465663 |
| Non-ducted, 2 tons | 78.6(50 is the typical model of its size class) (higher)048-MS-24K2VR-22S-M-OUTwith ductless indoor unit 048-MS-24K2VR-22S-M-INAlso listed as 048-MS-24K2VR-22S-MX-OUT6 of 13 models qualify · AHRI 216760022 | 77.6(50 is the typical model of its size class)DOD30-24HFN10-M1Xwith ductless indoor unit DSAG11D-23HRFN10-M15 of 5 models qualify · AHRI 217956859 |
| Non-ducted, 2.5 to 3 tons | 68.7(50 is the typical model of its size class) (higher)048-TPH-MODU-1D48 of 12 models qualify · AHRI 218471008 | 63.6(50 is the typical model of its size class)DOD30-36HFN10-M2with ductless indoor unit DCD-36HRFN10-M2-D3 of 4 models qualify · AHRI 218465667 |
| Non-ducted, 3.5 to 4.5 tons | 48.5(50 is the typical model of its size class)048-TPH-MODU-1D64 of 5 models qualify · AHRI 218471010 | 60.8(50 is the typical model of its size class) (higher)D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-D3 of 3 models qualify · AHRI 217956871 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | DellaAll-around score, best model | DUOHOMEAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.5(50 is the typical model of its size class)048-TPH-MODU-1D36 of 6 models have all five ratings · AHRI 218718739 | 81.3(50 is the typical model of its size class) (higher)DOX230-09HFN10-M1with ducted air handler DTJ-09HWFN10-M1-D6 of 7 models have all five ratings · AHRI 218465653 |
| Ducted, 2 tons | 55.8(50 is the typical model of its size class)048-TP-23K2V-23S-OUT3 of 3 models have all five ratings · AHRI 218082836 | 79.5(50 is the typical model of its size class) (higher)DOT-D24HNR8-EA01(J0)with ducted air handler DAH-D24HNR8-FMC(J0)6 of 7 models have all five ratings · AHRI 218258583 |
| Ducted, 2.5 to 3 tons | 80.0(50 is the typical model of its size class) (higher)048-TPH-MODU-1D46 of 6 models have all five ratings · AHRI 218718740 | 70.0(50 is the typical model of its size class)D5OD30-36HFN10-M1-DAlso listed as D5OD30-36HFN10-M1D-D9 of 11 models have all five ratings · AHRI 217956867 |
| Ducted, 3.5 to 4.5 tons | 66.2(50 is the typical model of its size class)048-TCQ-MODU-1D56 of 6 models have all five ratings · AHRI 218718738 | 85.3(50 is the typical model of its size class) (higher)D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-D9 of 12 models have all five ratings · AHRI 217956870 |
| Ducted, 5 tons and up | No models in this size class | 65.9(50 is the typical model of its size class)DOE30-60HFN10-M2with ducted air handler DHJ-60HWFN10-M2-D3 of 3 models have all five ratings · AHRI 218465659 |
| Non-ducted, up to 1.5 tons | 83.7(50 is the typical model of its size class) (higher)048-TPH-MODU-1D357 of 63 models have all five ratings · AHRI 218471007 | 77.1(50 is the typical model of its size class)DOX230-09HFN10-M1with ductless indoor unit DCA4-09HRFN10-M1-D11 of 11 models have all five ratings · AHRI 218465663 |
| Non-ducted, 2 tons | 70.2(50 is the typical model of its size class)048-MS-24K2VR-22S-M-OUTwith ductless indoor unit 048-MS-24K2VR-22S-M-INAlso listed as 048-MS-24K2VR-22S-MX-OUT12 of 13 models have all five ratings · AHRI 216760022 | 74.3(50 is the typical model of its size class) (higher)DOD30-24HFN10-M1Xwith ductless indoor unit DSAG11D-23HRFN10-M15 of 5 models have all five ratings · AHRI 217956859 |
| Non-ducted, 2.5 to 3 tons | 83.4(50 is the typical model of its size class) (higher)048-TPH-MODU-1D412 of 12 models have all five ratings · AHRI 218471008 | 59.3(50 is the typical model of its size class)D5OD30-36HFN10-M1-DAlso listed as D5OD30-36HFN10-M1D-D4 of 4 models have all five ratings · AHRI 217956866 |
| Non-ducted, 3.5 to 4.5 tons | 70.2(50 is the typical model of its size class) (higher)048-TPH-MODU-1D65 of 5 models have all five ratings · AHRI 218471010 | 53.1(50 is the typical model of its size class)D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-D3 of 3 models have all five ratings · AHRI 217956871 |
| Non-ducted, 5 tons and up | No models in this size class | 32.9(50 is the typical model of its size class)D6OE30-60HFN10-M1-DAlso listed as D6OE30-60HFN10-M1D-D2 of 2 models have all five ratings · AHRI 217956872 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Della | DUOHOME |
|---|---|---|
| COP at 5°F | beats 88% · 2.27048-MS-24K2VR-21S-OUTNon-ducted, 2 tons | beats 98% · 2.47DOX230-12HFN10-M1Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 96% · 105%048-TPH-MODU-1D3Ducted, up to 1.5 tons | beats 91% · 105%DOX630-36HFN10-M3XDucted, 2.5 to 3 tons |
| HSPF2 | beats 96% · 10.5048-TLP-MODU-1D4Ducted, 2.5 to 3 tons | beats 95% · 13.3DOD30-24HFN10-M1XNon-ducted, 2 tons |
| SEER2 | beats 100% · 22.0048-TPH-MODU-1D4Ducted, 2.5 to 3 tons | beats 96% · 20.4D6OE30-48HFN10-M1-DAlso listed as D6OE30-48HFN10-M1D-DDucted, 3.5 to 4.5 tons |
| EER2 | beats 97% · 14.0048-TPH-MODU-1D4Non-ducted, 2.5 to 3 tons | beats 93% · 13.3DOT-D24HNR8-EA01(J0)Ducted, 2 tons |
| Heating capacity at 5°F | beats 98% · 19,800 Btu/h048-TPH-MODU-1D3Non-ducted, up to 1.5 tons | beats 98% · 39,000 Btu/hDOX630-36HFN10-M3XDucted, 2.5 to 3 tons |