Both views use the same certified data. This device remembers your choice.
ECO-AIR vs Pioneer: heat pump ratings compared
Against heat pumps of the same size and type, a typical ECO-AIR model beats 57% and a typical Pioneer model 53%. ECO-AIR rates slightly higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
ECO-AIR
57%
of similar heat pumps beaten by its typical model
Above average61 models listed
Pioneer
53%
of similar heat pumps beaten by its typical model
About average61 models listed
- Efficiency on a 5°F dayCOP at 5°FECO-AIR: Beats 52%Pioneer: Beats 48%
- Heating power kept at 5°FCapacity at 5°F vs 47°FECO-AIR: Beats 54%Pioneer: Beats 43%
- Winter-long heating efficiencyHSPF2ECO-AIR: Beats 68%Pioneer: Beats 52%
- Summer-long cooling efficiencySEER2ECO-AIR: Beats 61%Pioneer: Beats 56%
- Hot-day cooling efficiencyEER2ECO-AIR: Beats 46%Pioneer: Beats 44%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- ECO-AIR
- 59%
- Pioneer
- 67%
Xcel CC
- ECO-AIR
- 43%
- Pioneer
- 46%
CEE Advanced
- ECO-AIR
- 2%
- Pioneer
- 0%
ENERGY STAR CC
- ECO-AIR
- 48%
- Pioneer
- 28%
All-around best, ducted 2.5 to 3 tons
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
ECO-AIR
- 1M4OX630-36HFN1-M1XECO-AIR3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 79.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.4 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 2M3OJ-27HFN1-MECO-AIR2.5 tons · 28,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 67% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 9.2 (HSPF2)
- Good
- Cooling efficiency
- 21.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
- 3M3OI-28HFN1-MECO-AIR (sold as Eco Air)2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 66.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 89% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
Pioneer
- 1YD036GMFI20MR2with ducted air handler DC036GMFI20HT2Pioneer3 tons · 34,200 Btu/h · DuctedNot a cold-climate pick: keeps 61% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 62% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.02 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 2YN030GMFI22M3EPioneer2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 57.7Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.83 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.2 (HSPF2)
- Good
- Cooling efficiency
- 21.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
- 3YH3036GHFD18R2with ducted air handler DR036GHFD18HT2Pioneer3 tons · 34,000 Btu/h · DuctedCold-climate pick, score 75.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.05 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 18.0 (SEER2)
- Great
- Hot-day cooling
- 10.1 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view