Both views use the same certified data. This device remembers your choice.
ForestAir vs KERR heat pumps
Measured against models of the same size and duct type, KERR scores higher on 6 of the 6 ratings. ForestAir has 22 outdoor models, KERR has 24 outdoor models. ForestAir and KERR have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ForestAir
- KERR
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ForestAir | KERR |
|---|---|---|
| Efficiency index | 58%median — | 67%median — |
| COP at 5°F | 46%median 1.80 | 50%median 1.95 |
| Capacity retention at 5°F | 56%median 77% | 78%median 91% |
| HSPF2 | 35%median 9.0 | 76%median 10.0 |
| SEER2 | 58%median 21.8 | 68%median 20.0 |
| EER2 | 47%median 12.0 | 58%median 11.9 |
| Heating capacity at 5°F | 56%median 13,200 Btu/h | 76%median 25,000 Btu/h |
| Outdoor models | 22 | 24 |
| AHRI certifications | 24 | 90 |
Share of models meeting each standard
| Standard | ForestAir | KERR |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 68.2%15 models | 83.3%20 models |
| CEE 2026 Tier 1 (Split ASHP) | 68.2%15 models | 83.3%20 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 8.3%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 54.5%12 models | 79.2%19 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 8.3%2 models |
| ENERGY STAR Cold Climate | 4.5%1 models | 87.5%21 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ForestAir
- KERR
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ForestAir | KERR |
|---|---|---|
| Ducted, 2 tons | 1 · index 61% | 3 · index 71% |
| Ducted, 3.5 to 4.5 tons | 1 · index 63% | 4 · index 63% |
| Ducted, up to 1.5 tons | None | 6 · index 60% |
| Ducted, 2.5 to 3 tons | None | 5 · index 67% |
| Non-ducted, up to 1.5 tons | 14 · index 57% | 7 · index 69% |
| Non-ducted, 2 tons | 4 · index 59% | 3 · index 79% |
| Non-ducted, 2.5 to 3 tons | 2 · index 53% | 6 · index 65% |
| Non-ducted, 3.5 to 4.5 tons | None | 2 · index 65% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ForestAirCold-climate score, best model | KERRCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 75.2(50 is the typical model of its size class)A-KMH09SV-1with ducted air handler B-KMH09DU-16 of 6 models qualify · AHRI 210568255 |
| Ducted, 2 tons | No models in this size class | 79.6(50 is the typical model of its size class)A-KMH24SU-1Awith ducted air handler B-KMH24DU-1Also listed as A-KMH24SV-13 of 3 models qualify · AHRI 206347321 |
| Ducted, 2.5 to 3 tons | 55.4(50 is the typical model of its size class)FAD36W/A-D(U)with ducted air handler FAD36AH2/A-D(U)1 of 1 models qualify · AHRI 208939392 | 79.9(50 is the typical model of its size class) (higher)A-KMH36QV-1A5 of 5 models qualify · AHRI 217169741 |
| Ducted, 3.5 to 4.5 tons | 58.3(50 is the typical model of its size class)FAD60W/A-D(U)with ducted air handler FAD48AH2/A-D(U)1 of 1 models qualify · AHRI 208939393 | 75.1(50 is the typical model of its size class) (higher)A-KMH48PV-14 of 4 models qualify · AHRI 207657607 |
| Non-ducted, up to 1.5 tons | 69.8(50 is the typical model of its size class)FA-H12-D23TL/O-ESwith ductless indoor unit FA-H12-D23TL/I-ES9 of 14 models qualify · AHRI 207797362 | 89.8(50 is the typical model of its size class) (higher)A-KMH06SV-1with ductless indoor unit B-KMH06SV-17 of 7 models qualify · AHRI 207657393 |
| Non-ducted, 2 tons | 52.4(50 is the typical model of its size class)FGH-24ES/E25-Owith ductless indoor unit FGH-24ES/E25-I1 of 4 models qualify · AHRI 211624984 | 87.1(50 is the typical model of its size class) (higher)A-KMH24SV-1with ductless indoor unit C-VMH24CV-13 of 3 models qualify · AHRI 207657400 |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 2 models qualify) | 91.3(50 is the typical model of its size class)A-KMH36QV-1A3 of 6 models qualify · AHRI 217169740 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 76.5(50 is the typical model of its size class)A-KMH48PV-12 of 2 models qualify · AHRI 207657606 |
All-around best
| Size and duct type | ForestAirAll-around score, best model | KERRAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 85.4(50 is the typical model of its size class)A-KMH09SV-1with ducted air handler B-KMH09DU-16 of 6 models have all five ratings · AHRI 210568255 |
| Ducted, 2 tons | 60.8(50 is the typical model of its size class)FAD36W/A-D(U)with ducted air handler FAD24AH2/A-D(U)1 of 1 models have all five ratings · AHRI 208939391 | 80.2(50 is the typical model of its size class) (higher)A-KMH24SU-1Awith ducted air handler B-KMH24DU-1Also listed as A-KMH24SV-13 of 3 models have all five ratings · AHRI 206347321 |
| Ducted, 2.5 to 3 tons | No models in this size class | 83.7(50 is the typical model of its size class)A-KMH36QV-1A5 of 5 models have all five ratings · AHRI 217169741 |
| Ducted, 3.5 to 4.5 tons | 63.3(50 is the typical model of its size class)FAD60W/A-D(U)with ducted air handler FAD48AH2/A-D(U)1 of 1 models have all five ratings · AHRI 208939393 | 82.1(50 is the typical model of its size class) (higher)A-KMH48PV-14 of 4 models have all five ratings · AHRI 207657607 |
| Non-ducted, up to 1.5 tons | 71.5(50 is the typical model of its size class)FA-H12-D23TL/O-ESwith ductless indoor unit FA-H12-D23TL/I-ES10 of 14 models have all five ratings · AHRI 207797362 | 92.3(50 is the typical model of its size class) (higher)A-KMH06SV-1with ductless indoor unit B-KMH06SV-17 of 7 models have all five ratings · AHRI 207657393 |
| Non-ducted, 2 tons | 72.5(50 is the typical model of its size class)FGH-24ES/E25-Owith ductless indoor unit FGH-24ES/E25-I3 of 4 models have all five ratings · AHRI 211624984 | 84.9(50 is the typical model of its size class) (higher)A-KMH24SV-1with ductless indoor unit B-KMH24SV-1Also listed as A-KMH24SU-13 of 3 models have all five ratings · AHRI 207657397 |
| Non-ducted, 2.5 to 3 tons | 52.7(50 is the typical model of its size class)FA-H36-D21TL/O4-ES1 of 2 models have all five ratings · AHRI 207804203 | 86.7(50 is the typical model of its size class) (higher)A-KMH36QV-1A5 of 6 models have all five ratings · AHRI 217169740 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 78.0(50 is the typical model of its size class)A-KMH48PV-12 of 2 models have all five ratings · AHRI 207657606 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ForestAir | KERR |
|---|---|---|
| COP at 5°F | beats 89% · 2.21FA-H18-D23TL/O-ESNon-ducted, up to 1.5 tons | beats 92% · 2.21A-KMH24SV-1Also listed as A-KMH24SU-1Non-ducted, 2 tons |
| Capacity retention at 5°F | beats 73% · 81%FAD60W/A-D(U)Ducted, 3.5 to 4.5 tons | beats 98% · 112%A-KCD36SA-1Ducted, 2.5 to 3 tons |
| HSPF2 | beats 73% · 9.0FAD60W/A-D(U)Ducted, 3.5 to 4.5 tons | beats 99% · 13.6A-KMH06SV-1Non-ducted, up to 1.5 tons |
| SEER2 | beats 97% · 24.0FGH-24ES/E25-ONon-ducted, 2 tons | beats 99% · 20.9A-KMH48PV-1Ducted, 3.5 to 4.5 tons |
| EER2 | beats 90% · 14.7FGH-09ES/E25-ONon-ducted, up to 1.5 tons | beats 98% · 16.2A-KMH09SV-1Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 87% · 14,500 Btu/hFGH-18ES/E25-ONon-ducted, up to 1.5 tons | beats 99% · 42,000 Btu/hA-KCD36SA-1Ducted, 2.5 to 3 tons |