Skip to content

FRANKLIN vs MAXI AIR heat pumps

Measured against models of the same size and duct type, MAXI AIR scores higher on 4 of the 6 ratings. FRANKLIN has 74 outdoor models, MAXI AIR has 19 outdoor models. FRANKLIN and MAXI AIR have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
FRANKLIN and MAXI AIR on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, MAXI AIR scores higher on 4 of the 6 ratings.
  • FRANKLIN
  • MAXI AIR
  • Other ranked manufacturers
FRANKLINMAXI AIR

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFRANKLINMAXI AIR
Efficiency index54%median —67%median —
COP at 5°F45% (higher)median 1.9242% (higher)median 1.87
Capacity retention at 5°F45%median 52%71%median 86%
HSPF244%median 7.875%median 10.3
SEER250%median 15.276%median 22.2
EER264% (higher)median 11.763% (higher)median 12.5
Heating capacity at 5°F42%median 17,300 Btu/h69%median 18,000 Btu/h
Outdoor models7419
AHRI certifications3,90845

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFRANKLINMAXI AIR
CEE 2025 Tier 1 (Split ASHP)33.8%25 models68.4%13 models
CEE 2026 Tier 1 (Split ASHP)31.1%23 models68.4%13 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)21.6%16 models73.7%14 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate18.9%14 models52.6%10 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 5 groups where both have models
  • FRANKLIN
  • MAXI AIR
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFRANKLINMAXI AIR
Ducted, up to 1.5 tons10 · index 54%None
Ducted, 2 tons12 · index 52%2 · index —
Ducted, 2.5 to 3 tons21 · index 50%7 · index 67%
Ducted, 3.5 to 4.5 tons24 · index 49%1 · index 53%
Ducted, 5 tons and up3 · index 42%None
Non-ducted, up to 1.5 tons8 · index 63%9 · index 64%
Non-ducted, 2 tons2 · index 72%None
Non-ducted, 2.5 to 3 tons6 · index 65%4 · index 79%
Non-ducted, 3.5 to 4.5 tons1 · index 78%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFRANKLINCold-climate score, best modelMAXI AIRCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class)MSH093E23MCAAwith ducted air handler MST093E21ADAA7 of 10 models qualify · AHRI 206900427No models in this size class
Ducted, 2 tons79.6(50 is the typical model of its size class)MSH243E23MCAAwith ducted air handler MST243E21ADAAAlso listed as MSH243F25MCAA2 of 12 models qualify · AHRI 206900430None on this board (0 of 2 models qualify)
Ducted, 2.5 to 3 tons80.4(50 is the typical model of its size class) (higher)MST273F25MHAA5 of 21 models qualify · AHRI 21438344368.2(50 is the typical model of its size class)MAXS-2430with ducted air handler NE-F52-MAC36HWD6 of 7 models qualify · AHRI 213265613
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class) (higher)MST483F25MHAA1 of 24 models qualify · AHRI 21438344971.7(50 is the typical model of its size class)MAXS-4260with ducted air handler AHMS-60201 of 1 models qualify · AHRI 210426581
Ducted, 5 tons and upNone on this board (0 of 3 models qualify)No models in this size class
Non-ducted, up to 1.5 tons77.3(50 is the typical model of its size class) (higher)MSH093F25MCAAwith ductless indoor unit MSH093F25AXAA8 of 8 models qualify · AHRI 21438343371.5(50 is the typical model of its size class)YS21F-18HRDN1with ductless indoor unit YS21F-18HRDN1Also listed as NE-T52-PLA18INT8 of 9 models qualify · AHRI 203238010
Non-ducted, 2 tons85.5(50 is the typical model of its size class)MSH243F25MCAAwith ductless indoor unit MSH243F25AXAA2 of 2 models qualify · AHRI 214383436No models in this size class
Non-ducted, 2.5 to 3 tons91.3(50 is the typical model of its size class) (higher)MST363F25MHAA3 of 6 models qualify · AHRI 21438344580.2(50 is the typical model of its size class)NE-T53-MULTI36EAlso listed as NE-T53-MULTI36E4 of 4 models qualify · AHRI 213927622
Non-ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class)MST483F25MHAA1 of 1 models qualify · AHRI 214383448No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFRANKLINAll-around score, best modelMAXI AIRAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class)MSH093E23MCAAwith ducted air handler MST093E21ADAA10 of 10 models have all five ratings · AHRI 206900427No models in this size class
Ducted, 2 tons80.2(50 is the typical model of its size class)MSH243E23MCAAwith ducted air handler MST243E21ADAAAlso listed as MSH243F25MCAA10 of 12 models have all five ratings · AHRI 206900430None on this board (0 of 2 models have all five ratings)
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class) (higher)MST363F25MHAA16 of 21 models have all five ratings · AHRI 21438344674.7(50 is the typical model of its size class)NE-T53-MULTI28EAlso listed as NE-T53-MULTI28E6 of 7 models have all five ratings · AHRI 213927620
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)MST483F25MHAA17 of 24 models have all five ratings · AHRI 21438344953.4(50 is the typical model of its size class)MAXS-4260with ducted air handler AHMS-60201 of 1 models have all five ratings · AHRI 210426581
Ducted, 5 tons and up54.3(50 is the typical model of its size class)MSH603E18MCAAwith ducted air handler MST603E18ADAA3 of 3 models have all five ratings · AHRI 206900445No models in this size class
Non-ducted, up to 1.5 tons87.6(50 is the typical model of its size class) (higher)MSH093F25MCAAwith ductless indoor unit MSH093F25AXAA8 of 8 models have all five ratings · AHRI 21438343376.4(50 is the typical model of its size class)YS21F-18HRDN1with ductless indoor unit YS21F-18HRDN1Also listed as NE-T52-PLA18INT9 of 9 models have all five ratings · AHRI 203238010
Non-ducted, 2 tons84.9(50 is the typical model of its size class)MSH243F25MCAAwith ductless indoor unit MSH243F25AXAA2 of 2 models have all five ratings · AHRI 214383436No models in this size class
Non-ducted, 2.5 to 3 tons86.7(50 is the typical model of its size class) (higher)MST363F25MHAA5 of 6 models have all five ratings · AHRI 21438344583.4(50 is the typical model of its size class)NE-T53-MULTI36EAlso listed as NE-T53-MULTI36E4 of 4 models have all five ratings · AHRI 213927622
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class)MST483F25MHAA1 of 1 models have all five ratings · AHRI 214383448No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFRANKLINMAXI AIR
COP at 5°Fbeats 95% · 2.51GPHH56041A*Ducted, 5 tons and upbeats 96% · 2.38YS21F-18HRDN1Also listed as NE-T52-PLA18INTNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 103%MST273F25MHAANon-ducted, 2.5 to 3 tonsbeats 86% · 97%NE-T53-MULTI36EAlso listed as NE-T53-MULTI36ENon-ducted, 2.5 to 3 tons
HSPF2beats 98% · 12.0MSH093E23MCAADucted, up to 1.5 tonsbeats 95% · 10.6NE-T53-MULTI28EAlso listed as NE-T53-MULTI28ENon-ducted, 2.5 to 3 tons
SEER2beats 99% · 20.9MST483F25MHAADucted, 3.5 to 4.5 tonsbeats 92% · 20.0NE-T53-MULTI28EAlso listed as NE-T53-MULTI28EDucted, 2.5 to 3 tons
EER2beats 98% · 16.2MSH093F25MCAANon-ducted, up to 1.5 tonsbeats 96% · 13.6NE-T53-MULTI36EAlso listed as NE-T53-MULTI36ENon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hMST183E23MHAAAlso listed as MST183F25MHAANon-ducted, up to 1.5 tonsbeats 95% · 48,500 Btu/hMAXS-4260Ducted, 3.5 to 4.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
FRANKLIN vs MAXI AIR: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • FRANKLIN (median, middle 50%)
  • MAXI AIR (median, middle 50%)
Heating capacity, % of its 47°F maximum71%73%COP at maximum capacity1.921.88

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
FRANKLIN: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
FRANKLIN, 47°F23100%100%100%100%100%
FRANKLIN, 17°F2370%75%78%80%86%
FRANKLIN, 5°F2356%59%71%80%83%
FRANKLIN: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
FRANKLIN, 47°F232.872.963.183.53.52
FRANKLIN, 17°F231.952.022.232.42.45
FRANKLIN, 5°F231.821.851.9222.15
MAXI AIR: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
MAXI AIR, 47°F15100%100%100%100%100%
MAXI AIR, 17°F1570%73%76%81%83%
MAXI AIR, 5°F1561%68%73%77%80%
MAXI AIR: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
MAXI AIR, 47°F152.792.872.953.153.5
MAXI AIR, 17°F151.922.052.212.392.46
MAXI AIR, 5°F151.81.81.8822.26

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter