Skip to content

FRANKLIN vs MAXI AIR heat pumps

Measured against models of the same size and duct type, MAXI AIR scores higher on 4 of the 6 ratings. FRANKLIN has 10 outdoor models, MAXI AIR has 10 outdoor models. FRANKLIN and MAXI AIR have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
FRANKLIN and MAXI AIR on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, MAXI AIR scores higher on 4 of the 6 ratings.
  • FRANKLIN
  • MAXI AIR
  • Other ranked manufacturers
FRANKLINMAXI AIR

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFRANKLINMAXI AIR
Efficiency index72%median —75%median —
COP at 5°F62% (higher)median 2.0052% (higher)median 2.00
Capacity retention at 5°F59%median 53%84%median 98%
HSPF272%median 8.283%median 10.5
SEER270%median 16.778%median 23.0
EER291% (higher)median 12.578% (higher)median 12.8
Heating capacity at 5°F58%median 22,500 Btu/h84%median 27,000 Btu/h
Outdoor models1010
AHRI certifications5034

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFRANKLINMAXI AIR
CEE 2025 Tier 1 (Split ASHP)70%7 models100%10 models
CEE 2026 Tier 1 (Split ASHP)70%7 models100%10 models
CEE Advanced Tier (Split ASHP)20%2 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)40%4 models100%10 models
DOE Cold Climate Heat Pump Challenge20%2 models0%0 models
ENERGY STAR Cold Climate40%4 models70%7 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 5 groups where both have models
  • FRANKLIN
  • MAXI AIR
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFRANKLINMAXI AIR
Ducted, up to 1.5 tons1 · index 92%2 · index 78%
Ducted, 2.5 to 3 tons1 · index 92%5 · index 77%
Ducted, 3.5 to 4.5 tons4 · index 56%1 · index 49%
Ducted, 5 tons and up2 · index 63%None
Non-ducted, up to 1.5 tons3 · index 82%4 · index 77%
Non-ducted, 2.5 to 3 tons1 · index 89%4 · index 77%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFRANKLINCold-climate score, best modelMAXI AIRCold-climate score, best model
Ducted, up to 1.5 tons86.5(50 is the typical model of its size class) (higher)MST183F32MHAA1 of 1 models qualify · AHRI 21808336171.1(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4542 of 2 models qualify · AHRI 218381880
Ducted, 2.5 to 3 tons90.3(50 is the typical model of its size class) (higher)MST273F32MHAA1 of 1 models qualify · AHRI 21808336482.7(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4545 of 5 models qualify · AHRI 217752780
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 4 models qualify)60.4(50 is the typical model of its size class)MAXS-4260-454with ducted air handler AHMS-6020-4541 of 1 models qualify · AHRI 217752767
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tons84.6(50 is the typical model of its size class) (higher)MST183F32MHAA3 of 3 models qualify · AHRI 21808336075.2(50 is the typical model of its size class)T55-AES18EXT454with ductless indoor unit T55-AES18INT4544 of 4 models qualify · AHRI 217752773
Non-ducted, 2.5 to 3 tons83.8(50 is the typical model of its size class) (higher)MST273F32MHAA1 of 1 models qualify · AHRI 21808336578.3(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4544 of 4 models qualify · AHRI 217752781

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFRANKLINAll-around score, best modelMAXI AIRAll-around score, best model
Ducted, up to 1.5 tons92.4(50 is the typical model of its size class) (higher)MST183F32MHAA1 of 1 models have all five ratings · AHRI 21808336177.8(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4542 of 2 models have all five ratings · AHRI 218381880
Ducted, 2.5 to 3 tons91.8(50 is the typical model of its size class) (higher)MST273F32MHAA1 of 1 models have all five ratings · AHRI 21808336483.9(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4545 of 5 models have all five ratings · AHRI 217752780
Ducted, 3.5 to 4.5 tons64.0(50 is the typical model of its size class) (higher)GLZT7CA4810A*with ducted air handler AMVT60DP1300A4 of 4 models have all five ratings · AHRI 21636930449.2(50 is the typical model of its size class)MAXS-4260-454with ducted air handler AHMS-6020-4541 of 1 models have all five ratings · AHRI 217752767
Ducted, 5 tons and up63.5(50 is the typical model of its size class)GLZS5BA6010A*with ducted air handler AMST60DU1300A2 of 2 models have all five ratings · AHRI 216369268No models in this size class
Non-ducted, up to 1.5 tons90.5(50 is the typical model of its size class) (higher)MST183F32MHAA3 of 3 models have all five ratings · AHRI 21808336083.1(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4544 of 4 models have all five ratings · AHRI 218381879
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)MST273F32MHAA1 of 1 models have all five ratings · AHRI 21808336378.8(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4544 of 4 models have all five ratings · AHRI 217752779

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFRANKLINMAXI AIR
COP at 5°Fbeats 92% · 2.20MST273F32MHAANon-ducted, 2.5 to 3 tonsbeats 64% · 2.00T55-MULTI18E454Also listed as T55-MULTI18E454Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 94% · 103%MST183F32MHAADucted, up to 1.5 tonsbeats 97% · 107%MAXS-2430-454Ducted, 2.5 to 3 tons
HSPF2beats 96% · 10.5MST273F32MHAADucted, 2.5 to 3 tonsbeats 93% · 10.4T55-MULTI36E454Also listed as T55-MULTI36E454Ducted, 2.5 to 3 tons
SEER2beats 97% · 22.0MST183F32MHAADucted, up to 1.5 tonsbeats 89% · 25.4T55-AES12EXT454Non-ducted, up to 1.5 tons
EER2beats 100% · 14.5MST183F32MHAADucted, up to 1.5 tonsbeats 92% · 15.0T55-MULTI18E454Also listed as T55-MULTI18E454Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 20,600 Btu/hMST183F32MHAADucted, up to 1.5 tonsbeats 97% · 19,000 Btu/hT55-MULTI18E454Also listed as T55-MULTI18E454Non-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter