- Insights
- Manufacturers
- MAXI AIR
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
MAXI AIR heat pump efficiency: 10 outdoor models compared
MAXI AIR has 10 heat pump outdoor models certified with this refrigerant group, in 34 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes MAXI AIR makes. MAXI AIR has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 10
- AHRI certifications
- 34
- Efficiency index
- 75%
- Typical model vs same-size, same-type peers (16 models)
- Meet CEE 2025
- 100%
- 10 models
How MAXI AIR compares with comparable models
- MAXI AIR
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index16 models scored | 75% | Not ranked | — |
| COP at 5°F16 models scored | 51% | Not ranked | 2.00 |
| Capacity retention at 5°F16 models scored | 83% | Not ranked | 98% |
| HSPF216 models scored | 83% | Not ranked | 10.5 |
| SEER216 models scored | 77% | Not ranked | 23.0 |
| EER216 models scored | 77% | Not ranked | 12.8 |
| Heating capacity at 5°F16 models scored | 84% | Not ranked | 27,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 10 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 10 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100% | 10 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 70% | 7 |
Sizes and duct types offered
- MAXI AIR (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | 77% | 63% | 79% | 83% |
| Ducted, 2.5–3 tons | 5 | 77% | 53% | 87% | 79% |
| Ducted, 3.5–4.5 tons | 1 | 49% | 21% | 73% | 54% |
| Non-ducted, up to 1.5 tons | 4 | 75% | 48% | 80% | 80% |
| Non-ducted, 2.5–3 tons | 4 | 76% | 53% | 85% | 76% |
Every MAXI AIR model in the market
- MAXI AIR models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top MAXI AIR models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1T55-MULTI36E454MAXI AIR · T55 SeriesAlso listed as T55-MULTI36E454 | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 38,000 | 19.4 | CEE 25CEE 26Xcel | 3 | 217752780 | Ducted, 2.5–3 tons | 82.5 |
| 2T55-MULTI36E454MAXI AIR · T55 SeriesAlso listed as T55-MULTI36E454 | 3 tons36,000 Btu/h · Non-ducted | 103% | 2.00 | 10.6 | 37,000 | 21.2 | CEE 25CEE 26Xcel | 3 | 217752781 | Non-ducted, 2.5–3 tons | 78.0 |
| 3T55-AES18EXT454MAXI AIR · T55 Serieswith ductless indoor unit T55-AES18INT454 | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 1.92 | 11.0 | 18,000 | 21.4 | CEE 25CEE 26XcelES CC | 2 | 217752773 | Non-ducted, up to 1.5 tons | 73.8 |
| 4T55-MULTI18E454MAXI AIR · T55 SeriesAlso listed as T55-MULTI18E454 | 1.5 tons19,000 Btu/h · Non-ducted | 95% | 2.00 | 10.4 | 19,000 | 25.0 | CEE 25CEE 26Xcel | 3 | 218381879 | Non-ducted, up to 1.5 tons | 73.1 |
| 5T55-MULTI28E454MAXI AIR · T55 SeriesAlso listed as T55-MULTI28E454 | 2.5 tons27,000 Btu/h · Non-ducted | 100% | 2.00 | 10.5 | 27,000 | 23.0 | CEE 25CEE 26Xcel | 3 | 217752776 | Non-ducted, 2.5–3 tons | 72.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1T55-MULTI36E454MAXI AIR · T55 SeriesAlso listed as T55-MULTI36E454 | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 19.4 | 12.0 | CEE 25CEE 26Xcel | 3 | 217752780 | Ducted, 2.5–3 tons | 83.6 | 82.5 | 84.8 | 82.5 |
| 2T55-MULTI18E454MAXI AIR · T55 SeriesAlso listed as T55-MULTI18E454 | 1.5 tons19,000 Btu/h · Non-ducted | 95% | 2.00 | 10.4 | 25.0 | 15.0 | CEE 25CEE 26Xcel | 3 | 218381879 | Non-ducted, up to 1.5 tons | 81.9 | 73.1 | 90.8 | 73.1 |
| 3T55-MULTI36E454MAXI AIR · T55 SeriesAlso listed as T55-MULTI36E454 | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.00 | 10.7 | 23.0 | 13.0 | CEE 25CEE 26Xcel | 3 | 217752779 | Non-ducted, 2.5–3 tons | 78.3 | 76.0 | 80.6 | 78.0 |
| 4T55-MULTI18E454MAXI AIR · T55 SeriesAlso listed as T55-MULTI18E454 | 1.5 tons19,000 Btu/h · Ducted | 90% | 2.00 | 10.0 | 20.0 | 13.0 | CEE 25CEE 26Xcel | 3 | 218381880 | Ducted, up to 1.5 tons | 77.4 | 70.8 | 84.0 | 70.8 |
| 5T55-MULTI28E454MAXI AIR · T55 SeriesAlso listed as T55-MULTI28E454 | 2.5 tons28,000 Btu/h · Ducted | 96% | 2.00 | 9.5 | 19.0 | 12.0 | CEE 25CEE 26Xcel | 3 | 217752777 | Ducted, 2.5–3 tons | 77.4 | 72.7 | 82.1 | 72.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | T55-MULTI18E454Also listed as T55-MULTI18E454 | 2.00 | Ducted, up to 1.5 tons | 63% | 218381880 |
| Capacity retention at 5°F | MAXS-2430-454 | 107% | Ducted, 2.5–3 tons | 97% | 218374112 |
| HSPF2 | T55-MULTI36E454Also listed as T55-MULTI36E454 | 10.4 | Ducted, 2.5–3 tons | 94% | 217752780 |
| SEER2 | T55-AES12EXT454 | 25.4 | Non-ducted, up to 1.5 tons | 88% | 217752772 |
| EER2 | T55-MULTI18E454Also listed as T55-MULTI18E454 | 15.0 | Non-ducted, up to 1.5 tons | 91% | 218381879 |
| Heating capacity at 5°F | T55-MULTI18E454Also listed as T55-MULTI18E454 | 19,000 Btu/h | Non-ducted, up to 1.5 tons | 97% | 218381879 |
MAXI AIR size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 70.8(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4542 of 2 models qualify · AHRI 218381880 | 77.4(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4542 of 2 models have all five ratings · AHRI 218381880 |
| Ducted, 2.5–3 tons | 82.5(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4545 of 5 models qualify · AHRI 217752780 | 83.6(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4545 of 5 models have all five ratings · AHRI 217752780 |
| Ducted, 3.5–4.5 tons | 60.5(50 is the typical model of its size class)MAXS-4260-454with ducted air handler AHMS-6020-4541 of 1 models qualify · AHRI 217752767 | 49.1(50 is the typical model of its size class)MAXS-4260-454with ducted air handler AHMS-6020-4541 of 1 models have all five ratings · AHRI 217752767 |
| Non-ducted, up to 1.5 tons | 73.8(50 is the typical model of its size class)T55-AES18EXT454with ductless indoor unit T55-AES18INT4544 of 4 models qualify · AHRI 217752773 | 81.9(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4544 of 4 models have all five ratings · AHRI 218381879 |
| Non-ducted, 2.5–3 tons | 78.0(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4544 of 4 models qualify · AHRI 217752781 | 78.3(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4544 of 4 models have all five ratings · AHRI 217752779 |
Newest MAXI AIR certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| T55-MULTI18E454*MAXI AIR · T55 Series | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 93% | 10.2 | 22.5 | CEE 25CEE 26XcelES CC | 3 | 218386542 |
| MAXS-4260-454MAXI AIR · MAXS Serieswith ducted air handler F32-MVBM60C28 | 4.5 tons52,000 Btu/h · Ducted | 1.80 | 80% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 4 | 218382947 |
| MAXS-2430-454MAXI AIR · MAXS Serieswith ducted air handler F32-MVBM36C24 | 2.5 tons29,000 Btu/h · Ducted | 1.85 | 107% | 9.6 | 16.0 | CEE 25CEE 26XcelES CC | 8 | 218382946 |
| T55-MULTI18E454MAXI AIR · T55 Series | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 93% | 10.2 | 22.5 | CEE 25CEE 26Xcel | 3 | 218381881 |
| T55-MULTI36E454*MAXI AIR · T55 Series | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 103% | 10.6 | 21.2 | CEE 25CEE 26XcelES CC | 3 | 217754316 |
Compare MAXI AIR
MAXI AIR includes these brand names as listed in AHRI: MAXI AIR. Standards are checked against published thresholds; program rules beyond ratings are not checked.