Both views use the same certified data. This device remembers your choice.
FRANKLIN vs Nortek Global HVAC heat pumps
Measured against models of the same size and duct type, FRANKLIN scores higher on 4 of the 6 ratings. FRANKLIN has 74 outdoor models, Nortek Global HVAC has 75 outdoor models. FRANKLIN has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- FRANKLIN
- Nortek Global HVAC
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | FRANKLIN | Nortek Global HVAC |
|---|---|---|
| Efficiency index | 54% (higher)median — | 47% (higher)median — · 23rd ranked |
| COP at 5°F | 45% (higher)median 1.92 | 40% (higher)median 1.82 · 25th ranked |
| Capacity retention at 5°F | 45%median 52% | 60%median 77% · 8th ranked |
| HSPF2 | 44% (higher)median 7.8 | 38% (higher)median 8.2 · 21st ranked |
| SEER2 | 50% (higher)median 15.2 | 39% (higher)median 16.5 · 22nd ranked |
| EER2 | 64% (higher)median 11.7 | 46% (higher)median 11.0 · 21st ranked |
| Heating capacity at 5°F | 42%median 17,300 Btu/h | 53%median 13,770 Btu/h · 16th ranked |
| Outdoor models | 74 | 75 |
| AHRI certifications | 3,908 | 280 |
Share of models meeting each standard
| Standard | FRANKLIN | Nortek Global HVAC |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.8%25 models | 41.3%31 models |
| CEE 2026 Tier 1 (Split ASHP) | 31.1%23 models | 40%30 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 21.6%16 models | 41.3%31 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 18.9%14 models | 24%18 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- FRANKLIN
- Nortek Global HVAC
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | FRANKLIN | Nortek Global HVAC |
|---|---|---|
| Ducted, up to 1.5 tons | 10 · index 54% | 10 · index 48% |
| Ducted, 2 tons | 12 · index 52% | 7 · index 52% |
| Ducted, 2.5 to 3 tons | 21 · index 50% | 20 · index 55% |
| Ducted, 3.5 to 4.5 tons | 24 · index 49% | 13 · index 58% |
| Ducted, 5 tons and up | 3 · index 42% | None |
| Non-ducted, up to 1.5 tons | 8 · index 63% | 23 · index 41% |
| Non-ducted, 2 tons | 2 · index 72% | 7 · index 48% |
| Non-ducted, 2.5 to 3 tons | 6 · index 65% | 10 · index 49% |
| Non-ducted, 3.5 to 4.5 tons | 1 · index 78% | 1 · index 44% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FRANKLINCold-climate score, best model | Nortek Global HVACCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 75.2(50 is the typical model of its size class) (higher)MSH093E23MCAAwith ducted air handler MST093E21ADAA7 of 10 models qualify · AHRI 206900427 | 56.7(50 is the typical model of its size class)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models qualify · AHRI 207237540 |
| Ducted, 2 tons | 79.6(50 is the typical model of its size class) (higher)MSH243E23MCAAwith ducted air handler MST243E21ADAAAlso listed as MSH243F25MCAA2 of 12 models qualify · AHRI 206900430 | 68.4(50 is the typical model of its size class)WHM24SZA21Swith ducted air handler D(A,C,E)24D44+TDR4 of 6 models qualify · AHRI 214640590 |
| Ducted, 2.5 to 3 tons | 80.4(50 is the typical model of its size class) (higher)MST273F25MHAA5 of 21 models qualify · AHRI 214383443 | 78.4(50 is the typical model of its size class)WHU36SZA21Swith ducted air handler WHU36DHA21S7 of 21 models qualify · AHRI 207237544 |
| Ducted, 3.5 to 4.5 tons | 75.1(50 is the typical model of its size class) (higher)MST483F25MHAA1 of 24 models qualify · AHRI 214383449 | 73.4(50 is the typical model of its size class)WHM60SZA21Swith ducted air handler D(A,C,E)60B44+TDR4 of 13 models qualify · AHRI 214640596 |
| Ducted, 5 tons and up | None on this board (0 of 3 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | 77.3(50 is the typical model of its size class)MSH093F25MCAAwith ductless indoor unit MSH093F25AXAA8 of 8 models qualify · AHRI 214383433 | 79.0(50 is the typical model of its size class) (higher)WHU09SZA21Swith ductless indoor unit WHU09CTA21S16 of 23 models qualify · AHRI 207237535 |
| Non-ducted, 2 tons | 85.5(50 is the typical model of its size class) (higher)MSH243F25MCAAwith ductless indoor unit MSH243F25AXAA2 of 2 models qualify · AHRI 214383436 | 77.3(50 is the typical model of its size class)GXH24(7.0)FMK4DH-15 of 7 models qualify · AHRI 210276801 |
| Non-ducted, 2.5 to 3 tons | 91.3(50 is the typical model of its size class) (higher)MST363F25MHAA3 of 6 models qualify · AHRI 214383445 | 78.2(50 is the typical model of its size class)WHU36SZA21Swith ductless indoor unit WHU36CTA21S7 of 10 models qualify · AHRI 207237539 |
| Non-ducted, 3.5 to 4.5 tons | 76.5(50 is the typical model of its size class) (higher)MST483F25MHAA1 of 1 models qualify · AHRI 214383448 | 41.8(50 is the typical model of its size class)WHP42M5A21S1 of 1 models qualify · AHRI 208404161 |
All-around best
| Size and duct type | FRANKLINAll-around score, best model | Nortek Global HVACAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class) (higher)MSH093E23MCAAwith ducted air handler MST093E21ADAA10 of 10 models have all five ratings · AHRI 206900427 | 58.1(50 is the typical model of its size class)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models have all five ratings · AHRI 207237540 |
| Ducted, 2 tons | 80.2(50 is the typical model of its size class) (higher)MSH243E23MCAAwith ducted air handler MST243E21ADAAAlso listed as MSH243F25MCAA10 of 12 models have all five ratings · AHRI 206900430 | 71.7(50 is the typical model of its size class)WHP24M3A21S6 of 7 models have all five ratings · AHRI 208404156 |
| Ducted, 2.5 to 3 tons | 83.7(50 is the typical model of its size class) (higher)MST363F25MHAA16 of 21 models have all five ratings · AHRI 214383446 | 78.7(50 is the typical model of its size class)WHP36M4A21S7 of 20 models have all five ratings · AHRI 208404158 |
| Ducted, 3.5 to 4.5 tons | 82.1(50 is the typical model of its size class) (higher)MST483F25MHAA17 of 24 models have all five ratings · AHRI 214383449 | 65.6(50 is the typical model of its size class)WHM48SZA21Swith ducted air handler DC61A44-245R4 of 13 models have all five ratings · AHRI 213886028 |
| Ducted, 5 tons and up | 54.3(50 is the typical model of its size class)MSH603E18MCAAwith ducted air handler MST603E18ADAA3 of 3 models have all five ratings · AHRI 206900445 | No models in this size class |
| Non-ducted, up to 1.5 tons | 87.6(50 is the typical model of its size class) (higher)MSH093F25MCAAwith ductless indoor unit MSH093F25AXAA8 of 8 models have all five ratings · AHRI 214383433 | 85.9(50 is the typical model of its size class)WHZ09SZA21Swith ductless indoor unit WHZ09WMA21S23 of 24 models have all five ratings · AHRI 207337194 |
| Non-ducted, 2 tons | 84.9(50 is the typical model of its size class) (higher)MSH243F25MCAAwith ductless indoor unit MSH243F25AXAA2 of 2 models have all five ratings · AHRI 214383436 | 72.2(50 is the typical model of its size class)GXH24(7.0)FMK4DH-17 of 7 models have all five ratings · AHRI 210276801 |
| Non-ducted, 2.5 to 3 tons | 86.7(50 is the typical model of its size class) (higher)MST363F25MHAA5 of 6 models have all five ratings · AHRI 214383445 | 70.9(50 is the typical model of its size class)GXH42(12.3)FMK4DH-110 of 10 models have all five ratings · AHRI 210276799 |
| Non-ducted, 3.5 to 4.5 tons | 78.0(50 is the typical model of its size class)MST483F25MHAA1 of 1 models have all five ratings · AHRI 214383448 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | FRANKLIN | Nortek Global HVAC |
|---|---|---|
| COP at 5°F | beats 95% · 2.51GPHH56041A*Ducted, 5 tons and up | beats 96% · 2.28WHU36SZA21SNon-ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 98% · 103%MST273F25MHAANon-ducted, 2.5 to 3 tons | beats 99% · 113%WHP36M4A21SNon-ducted, 2.5 to 3 tons |
| HSPF2 | beats 98% · 12.0MSH093E23MCAADucted, up to 1.5 tons | beats 83% · 9.5WHU36SZA21SDucted, 2.5 to 3 tons |
| SEER2 | beats 99% · 20.9MST483F25MHAADucted, 3.5 to 4.5 tons | beats 96% · 27.5WHZ09SZA21SNon-ducted, up to 1.5 tons |
| EER2 | beats 98% · 16.2MSH093F25MCAANon-ducted, up to 1.5 tons | beats 93% · 15.5WHZ09SZA21SNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 96% · 20,000 Btu/hMST183E23MHAAAlso listed as MST183F25MHAANon-ducted, up to 1.5 tons | beats 93% · 36,000 Btu/hWHP36M4A21SDucted, 2.5 to 3 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- FRANKLIN (median, middle 50%)
- Nortek Global HVAC (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 3,710 | 65% | 68% | 76% | 83% | 92% |
| All rated models, 5°F | 3,710 | 55% | 58% | 66% | 75% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 2.64 | 2.87 | 3.1 | 3.32 | 3.53 |
| All rated models, 17°F | 3,710 | 1.98 | 2.05 | 2.2 | 2.34 | 2.49 |
| All rated models, 5°F | 3,710 | 1.8 | 1.83 | 1.92 | 2.03 | 2.21 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| FRANKLIN, 47°F | 23 | 100% | 100% | 100% | 100% | 100% |
| FRANKLIN, 17°F | 23 | 70% | 75% | 78% | 80% | 86% |
| FRANKLIN, 5°F | 23 | 56% | 59% | 71% | 80% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| FRANKLIN, 47°F | 23 | 2.87 | 2.96 | 3.18 | 3.5 | 3.52 |
| FRANKLIN, 17°F | 23 | 1.95 | 2.02 | 2.23 | 2.4 | 2.45 |
| FRANKLIN, 5°F | 23 | 1.82 | 1.85 | 1.92 | 2 | 2.15 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Nortek Global HVAC, 47°F | 29 | 100% | 100% | 100% | 100% | 100% |
| Nortek Global HVAC, 17°F | 29 | 72% | 78% | 85% | 90% | 97% |
| Nortek Global HVAC, 5°F | 29 | 64% | 69% | 75% | 75% | 78% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Nortek Global HVAC, 47°F | 29 | 2.33 | 2.7 | 3 | 3.2 | 3.34 |
| Nortek Global HVAC, 17°F | 29 | 1.9 | 2.02 | 2.2 | 2.3 | 2.42 |
| Nortek Global HVAC, 5°F | 29 | 1.8 | 1.84 | 1.92 | 2.1 | 2.22 |
Source: NEEP ccASHP list · as of