Skip to content

FRANKLIN vs Nortek Global HVAC heat pumps

Measured against models of the same size and duct type, FRANKLIN scores higher on 4 of the 6 ratings. FRANKLIN has 74 outdoor models, Nortek Global HVAC has 75 outdoor models. FRANKLIN has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
FRANKLIN and Nortek Global HVAC on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, FRANKLIN scores higher on 4 of the 6 ratings.
  • FRANKLIN
  • Nortek Global HVAC
  • Other ranked manufacturers
FRANKLINNortek G…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFRANKLINNortek Global HVAC
Efficiency index54% (higher)median —47% (higher)median — · 23rd ranked
COP at 5°F45% (higher)median 1.9240% (higher)median 1.82 · 25th ranked
Capacity retention at 5°F45%median 52%60%median 77% · 8th ranked
HSPF244% (higher)median 7.838% (higher)median 8.2 · 21st ranked
SEER250% (higher)median 15.239% (higher)median 16.5 · 22nd ranked
EER264% (higher)median 11.746% (higher)median 11.0 · 21st ranked
Heating capacity at 5°F42%median 17,300 Btu/h53%median 13,770 Btu/h · 16th ranked
Outdoor models7475
AHRI certifications3,908280

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFRANKLINNortek Global HVAC
CEE 2025 Tier 1 (Split ASHP)33.8%25 models41.3%31 models
CEE 2026 Tier 1 (Split ASHP)31.1%23 models40%30 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)21.6%16 models41.3%31 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate18.9%14 models24%18 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • FRANKLIN
  • Nortek Global HVAC
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFRANKLINNortek Global HVAC
Ducted, up to 1.5 tons10 · index 54%10 · index 48%
Ducted, 2 tons12 · index 52%7 · index 52%
Ducted, 2.5 to 3 tons21 · index 50%20 · index 55%
Ducted, 3.5 to 4.5 tons24 · index 49%13 · index 58%
Ducted, 5 tons and up3 · index 42%None
Non-ducted, up to 1.5 tons8 · index 63%23 · index 41%
Non-ducted, 2 tons2 · index 72%7 · index 48%
Non-ducted, 2.5 to 3 tons6 · index 65%10 · index 49%
Non-ducted, 3.5 to 4.5 tons1 · index 78%1 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFRANKLINCold-climate score, best modelNortek Global HVACCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class) (higher)MSH093E23MCAAwith ducted air handler MST093E21ADAA7 of 10 models qualify · AHRI 20690042756.7(50 is the typical model of its size class)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models qualify · AHRI 207237540
Ducted, 2 tons79.6(50 is the typical model of its size class) (higher)MSH243E23MCAAwith ducted air handler MST243E21ADAAAlso listed as MSH243F25MCAA2 of 12 models qualify · AHRI 20690043068.4(50 is the typical model of its size class)WHM24SZA21Swith ducted air handler D(A,C,E)24D44+TDR4 of 6 models qualify · AHRI 214640590
Ducted, 2.5 to 3 tons80.4(50 is the typical model of its size class) (higher)MST273F25MHAA5 of 21 models qualify · AHRI 21438344378.4(50 is the typical model of its size class)WHU36SZA21Swith ducted air handler WHU36DHA21S7 of 21 models qualify · AHRI 207237544
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class) (higher)MST483F25MHAA1 of 24 models qualify · AHRI 21438344973.4(50 is the typical model of its size class)WHM60SZA21Swith ducted air handler D(A,C,E)60B44+TDR4 of 13 models qualify · AHRI 214640596
Ducted, 5 tons and upNone on this board (0 of 3 models qualify)No models in this size class
Non-ducted, up to 1.5 tons77.3(50 is the typical model of its size class)MSH093F25MCAAwith ductless indoor unit MSH093F25AXAA8 of 8 models qualify · AHRI 21438343379.0(50 is the typical model of its size class) (higher)WHU09SZA21Swith ductless indoor unit WHU09CTA21S16 of 23 models qualify · AHRI 207237535
Non-ducted, 2 tons85.5(50 is the typical model of its size class) (higher)MSH243F25MCAAwith ductless indoor unit MSH243F25AXAA2 of 2 models qualify · AHRI 21438343677.3(50 is the typical model of its size class)GXH24(7.0)FMK4DH-15 of 7 models qualify · AHRI 210276801
Non-ducted, 2.5 to 3 tons91.3(50 is the typical model of its size class) (higher)MST363F25MHAA3 of 6 models qualify · AHRI 21438344578.2(50 is the typical model of its size class)WHU36SZA21Swith ductless indoor unit WHU36CTA21S7 of 10 models qualify · AHRI 207237539
Non-ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class) (higher)MST483F25MHAA1 of 1 models qualify · AHRI 21438344841.8(50 is the typical model of its size class)WHP42M5A21S1 of 1 models qualify · AHRI 208404161

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFRANKLINAll-around score, best modelNortek Global HVACAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class) (higher)MSH093E23MCAAwith ducted air handler MST093E21ADAA10 of 10 models have all five ratings · AHRI 20690042758.1(50 is the typical model of its size class)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models have all five ratings · AHRI 207237540
Ducted, 2 tons80.2(50 is the typical model of its size class) (higher)MSH243E23MCAAwith ducted air handler MST243E21ADAAAlso listed as MSH243F25MCAA10 of 12 models have all five ratings · AHRI 20690043071.7(50 is the typical model of its size class)WHP24M3A21S6 of 7 models have all five ratings · AHRI 208404156
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class) (higher)MST363F25MHAA16 of 21 models have all five ratings · AHRI 21438344678.7(50 is the typical model of its size class)WHP36M4A21S7 of 20 models have all five ratings · AHRI 208404158
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)MST483F25MHAA17 of 24 models have all five ratings · AHRI 21438344965.6(50 is the typical model of its size class)WHM48SZA21Swith ducted air handler DC61A44-245R4 of 13 models have all five ratings · AHRI 213886028
Ducted, 5 tons and up54.3(50 is the typical model of its size class)MSH603E18MCAAwith ducted air handler MST603E18ADAA3 of 3 models have all five ratings · AHRI 206900445No models in this size class
Non-ducted, up to 1.5 tons87.6(50 is the typical model of its size class) (higher)MSH093F25MCAAwith ductless indoor unit MSH093F25AXAA8 of 8 models have all five ratings · AHRI 21438343385.9(50 is the typical model of its size class)WHZ09SZA21Swith ductless indoor unit WHZ09WMA21S23 of 24 models have all five ratings · AHRI 207337194
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)MSH243F25MCAAwith ductless indoor unit MSH243F25AXAA2 of 2 models have all five ratings · AHRI 21438343672.2(50 is the typical model of its size class)GXH24(7.0)FMK4DH-17 of 7 models have all five ratings · AHRI 210276801
Non-ducted, 2.5 to 3 tons86.7(50 is the typical model of its size class) (higher)MST363F25MHAA5 of 6 models have all five ratings · AHRI 21438344570.9(50 is the typical model of its size class)GXH42(12.3)FMK4DH-110 of 10 models have all five ratings · AHRI 210276799
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class)MST483F25MHAA1 of 1 models have all five ratings · AHRI 214383448No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFRANKLINNortek Global HVAC
COP at 5°Fbeats 95% · 2.51GPHH56041A*Ducted, 5 tons and upbeats 96% · 2.28WHU36SZA21SNon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 98% · 103%MST273F25MHAANon-ducted, 2.5 to 3 tonsbeats 99% · 113%WHP36M4A21SNon-ducted, 2.5 to 3 tons
HSPF2beats 98% · 12.0MSH093E23MCAADucted, up to 1.5 tonsbeats 83% · 9.5WHU36SZA21SDucted, 2.5 to 3 tons
SEER2beats 99% · 20.9MST483F25MHAADucted, 3.5 to 4.5 tonsbeats 96% · 27.5WHZ09SZA21SNon-ducted, up to 1.5 tons
EER2beats 98% · 16.2MSH093F25MCAANon-ducted, up to 1.5 tonsbeats 93% · 15.5WHZ09SZA21SNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hMST183E23MHAAAlso listed as MST183F25MHAANon-ducted, up to 1.5 tonsbeats 93% · 36,000 Btu/hWHP36M4A21SDucted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
FRANKLIN vs Nortek Global HVAC: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • FRANKLIN (median, middle 50%)
  • Nortek Global HVAC (median, middle 50%)
Heating capacity, % of its 47°F maximum71%75%COP at maximum capacity1.921.92

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
FRANKLIN: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
FRANKLIN, 47°F23100%100%100%100%100%
FRANKLIN, 17°F2370%75%78%80%86%
FRANKLIN, 5°F2356%59%71%80%83%
FRANKLIN: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
FRANKLIN, 47°F232.872.963.183.53.52
FRANKLIN, 17°F231.952.022.232.42.45
FRANKLIN, 5°F231.821.851.9222.15
Nortek Global HVAC: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Nortek Global HVAC, 47°F29100%100%100%100%100%
Nortek Global HVAC, 17°F2972%78%85%90%97%
Nortek Global HVAC, 5°F2964%69%75%75%78%
Nortek Global HVAC: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Nortek Global HVAC, 47°F292.332.733.23.34
Nortek Global HVAC, 17°F291.92.022.22.32.42
Nortek Global HVAC, 5°F291.81.841.922.12.22

Source: NEEP ccASHP list · as of

More comparisons