Skip to content

Friedrich vs Gree heat pumps

Measured against models of the same size and duct type, Gree scores higher on 5 of the 6 ratings. Friedrich has 117 outdoor models, Gree has 403 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Friedrich and Gree on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Gree scores higher on 5 of the 6 ratings.
  • Friedrich
  • Gree
  • Other ranked manufacturers
FriedrichGree

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFriedrichGree
Efficiency index44%median — · 26th ranked48%median — · 21st ranked
COP at 5°F57% (higher)median 2.10 · 9th ranked40% (higher)median 1.82 · 26th ranked
Capacity retention at 5°F44%median 58% · 21st ranked57%median 74% · 12th ranked
HSPF232%median 7.5 · 26th ranked44%median 8.5 · 19th ranked
SEER236%median 15.2 · 26th ranked50%median 18.0 · 14th ranked
EER239%median 10.6 · 26th ranked44%median 11.3 · 23rd ranked
Heating capacity at 5°F39%median 15,600 Btu/h · 25th ranked55%median 19,000 Btu/h · 12th ranked
Outdoor models117403
AHRI certifications3,0916,632

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFriedrichGree
CEE 2025 Tier 1 (Split ASHP)37.6%44 models59.8%241 models
CEE 2026 Tier 1 (Split ASHP)37.6%44 models57.3%231 models
CEE Advanced Tier (Split ASHP)1.7%2 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)32.5%38 models60%242 models
DOE Cold Climate Heat Pump Challenge1.7%2 models0%0 models
ENERGY STAR Cold Climate24.8%29 models42.2%170 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • Friedrich
  • Gree
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsNon-ducted, 5 tons and up2.0137 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFriedrichGree
Ducted, up to 1.5 tons21 · index 27%44 · index 43%
Ducted, 2 tons16 · index 45%55 · index 46%
Ducted, 2.5 to 3 tons22 · index 52%83 · index 45%
Ducted, 3.5 to 4.5 tons28 · index 47%73 · index 45%
Ducted, 5 tons and up7 · index —9 · index 46%
Non-ducted, up to 1.5 tons19 · index 56%139 · index 47%
Non-ducted, 2 tons6 · index 48%37 · index 53%
Non-ducted, 2.5 to 3 tons6 · index 26%54 · index 58%
Non-ducted, 3.5 to 4.5 tons1 · index 44%15 · index 45%
Non-ducted, 5 tons and upNone6 · index 47%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFriedrichCold-climate score, best modelGreeCold-climate score, best model
Ducted, up to 1.5 tons56.7(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A4 of 20 models qualify · AHRI 20504819871.0(50 is the typical model of its size class) (higher)AOX330-09HFN1-MY5Wwith ducted air handler ATIU-09HWFN1-MAlso listed as AOX230-09HFN1-MW5W36 of 44 models qualify · AHRI 207827154
Ducted, 2 tons74.7(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU5 of 17 models qualify · AHRI 21382971082.7(50 is the typical model of its size class) (higher)AOD32-24HFN1-MT0Wwith ducted air handler ATIU-24HWFN1-M43 of 56 models qualify · AHRI 207827157
Ducted, 2.5 to 3 tons80.5(50 is the typical model of its size class) (higher)FRP18AZ36AJVCwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU5 of 22 models qualify · AHRI 21382972278.5(50 is the typical model of its size class)AOE31U-36HFN1-Mwith ducted air handler AVBL-36HWFN1-MK348 of 83 models qualify · AHRI 213386505
Ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class) (higher)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR962V1005A21M47 of 28 models qualify · AHRI 21427902868.4(50 is the typical model of its size class)GUD60W/A-D(U)with ducted air handler C(A,C,D,E)48C44+TDRAlso sold as Tosot TU60-48WADU25 of 72 models qualify · AHRI 212925904
Ducted, 5 tons and upNone on this board (0 of 7 models qualify)64.1(50 is the typical model of its size class)TVRF-V60WL/C3 of 9 models qualify · AHRI 214717101
Non-ducted, up to 1.5 tons79.0(50 is the typical model of its size class)FPHFR09A3Awith ductless indoor unit FPHFC09A3B18 of 19 models qualify · AHRI 20504819786.6(50 is the typical model of its size class) (higher)AOX230-09HFN1-MW5Wwith ductless indoor unit ASEPB-09HRFN1-MY5W(GA)120 of 139 models qualify · AHRI 207827145
Non-ducted, 2 tons73.4(50 is the typical model of its size class)FPHFR24A3Awith ductless indoor unit FPHFC24A3B5 of 6 models qualify · AHRI 20512380577.3(50 is the typical model of its size class) (higher)GWHD(24)ND3MOAlso sold as Ac Pro.Com AWHD(24)ND3MO, Tosot TM24HX4O, Kinghome KM24H5O, Tosot TM24HMO and 1 more; also listed as MULTI24HP230V1EO, WLWHD(24)ND3MO26 of 37 models qualify · AHRI 208786090
Non-ducted, 2.5 to 3 tons78.2(50 is the typical model of its size class) (higher)FPHFR36A3Awith ductless indoor unit FPHSC36A3B2 of 6 models qualify · AHRI 20515042174.7(50 is the typical model of its size class)GWHD(42)ND3MOAlso sold as Ac Pro.Com AWHD(42)ND3MO, Tosot TM42HX4O, Kinghome KM42H5O, Tosot TM42HMO; also listed as MULTI42HP230V1EO, WLWHD(42)ND3MO43 of 54 models qualify · AHRI 208786088
Non-ducted, 3.5 to 4.5 tons41.8(50 is the typical model of its size class)FPHMR42A3A1 of 1 models qualify · AHRI 20514151357.8(50 is the typical model of its size class) (higher)GMV-V48WL/C-T(U)Also sold as Tosot TVRF-V48WL/C, Kinghome KUV-48UHO10 of 15 models qualify · AHRI 211698447
Non-ducted, 5 tons and upNo models in this size class42.1(50 is the typical model of its size class)GMV-V60WL/C-T(U)Also sold as Tosot TVRF-V60WL/C, Kinghome KUV-60UHO3 of 6 models qualify · AHRI 211694660

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFriedrichAll-around score, best modelGreeAll-around score, best model
Ducted, up to 1.5 tons58.1(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A16 of 20 models have all five ratings · AHRI 20504819878.8(50 is the typical model of its size class) (higher)AOX430-18HFN1-MT8Wwith ducted air handler ATIU-18HWFN1-M41 of 44 models have all five ratings · AHRI 217284664
Ducted, 2 tons83.5(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU12 of 17 models have all five ratings · AHRI 21382971085.0(50 is the typical model of its size class) (higher)AOD32-24HFN1-MT0Wwith ducted air handler ATIU-24HWFN1-M54 of 61 models have all five ratings · AHRI 207827157
Ducted, 2.5 to 3 tons86.0(50 is the typical model of its size class) (higher)FRP18AZ36AJVCwith ducted air handler FRHMVZ6021SEACA12 of 22 models have all five ratings · AHRI 21308728775.5(50 is the typical model of its size class)4HP17L36P-**Awith ducted air handler LGM59467 of 78 models have all five ratings · AHRI 211017923
Ducted, 3.5 to 4.5 tons80.4(50 is the typical model of its size class) (higher)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR802V1005A21UH17 of 27 models have all five ratings · AHRI 21461015376.5(50 is the typical model of its size class)4HP17L48P-**Awith ducted air handler LGM59455 of 71 models have all five ratings · AHRI 211017925
Ducted, 5 tons and up69.9(50 is the typical model of its size class) (higher)FWP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace FR97MV1005A21DH1 of 8 models have all five ratings · AHRI 21384173868.8(50 is the typical model of its size class)4HP17L60P-**Awith ducted air handler L(E,G)M60H410 of 10 models have all five ratings · AHRI 212509478
Non-ducted, up to 1.5 tons85.6(50 is the typical model of its size class)MRH09Y3JAwith ductless indoor unit MWH09Y3JA18 of 19 models have all five ratings · AHRI 20176389789.1(50 is the typical model of its size class) (higher)GWH09ACD-D3DNA1A/Owith ductless indoor unit GWH09ACD-D3DN***/IAlso sold as Tosot TW09HQ3D6DO, Ac Pro.Com AWH09ACD-D3DNA1A/O, Kinghome KW09HQ3D6DO139 of 139 models have all five ratings · AHRI 10318077
Non-ducted, 2 tons68.5(50 is the typical model of its size class)FPHMR24A3A6 of 6 models have all five ratings · AHRI 20410124678.6(50 is the typical model of its size class) (higher)AOD32-24HFN1-MT0Wwith ductless indoor unit ASEPD-24HRFN1-MU0W32 of 37 models have all five ratings · AHRI 207827148
Non-ducted, 2.5 to 3 tons70.2(50 is the typical model of its size class)FPHMR36A3A6 of 6 models have all five ratings · AHRI 20410124778.9(50 is the typical model of its size class) (higher)A3OJ-27HFN1-M52 of 54 models have all five ratings · AHRI 217284634
Non-ducted, 3.5 to 4.5 tons44.4(50 is the typical model of its size class)FPHMR42A3A1 of 1 models have all five ratings · AHRI 20514151269.1(50 is the typical model of its size class) (higher)GMV-V48WL/C-T(U)Also sold as Tosot TVRF-V48WL/C, Kinghome KUV-48UHO14 of 15 models have all five ratings · AHRI 211698447
Non-ducted, 5 tons and upNo models in this size class53.7(50 is the typical model of its size class)GMV-V60WL/C-T(U)Also sold as Tosot TVRF-V60WL/C, Kinghome KUV-60UHO6 of 6 models have all five ratings · AHRI 211694660

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFriedrichGree
COP at 5°Fbeats 97% · 2.80WFPU17Z243CDucted, up to 1.5 tonsbeats 99% · 2.30KW48HVRONon-ducted, 3.5 to 4.5 tons
Capacity retention at 5°Fbeats 100% · 105%FRP18AZ48AJVCDucted, 3.5 to 4.5 tonsbeats 99% · 144%GWH09ACD-D3DNA1A/OAlso sold as Tosot TW09HQ3D6DO, Ac Pro.Com AWH09ACD-D3DNA1A/O, Kinghome KW09HQ3D6DONon-ducted, up to 1.5 tons
HSPF2beats 83% · 9.5FPHFR36A3ADucted, 2.5 to 3 tonsbeats 98% · 11.2AOD32-24HFN1-MT0WDucted, 2 tons
SEER2beats 96% · 27.5MRH09Y3JANon-ducted, up to 1.5 tonsbeats 99% · 24.6A3OJ-27HFN1-MNon-ducted, 2.5 to 3 tons
EER2beats 93% · 15.5MRH09Y3JANon-ducted, up to 1.5 tonsbeats 100% · 14.54HP17L24P-**ADucted, 2 tons
Heating capacity at 5°Fbeats 100% · 43,500 Btu/hFRP18AZ36AJVCDucted, 2.5 to 3 tonsbeats 99% · 21,800 Btu/hGWHD(18)ND3JOAlso sold as Tosot TM18H5O, Kinghome KM18UH5O; also listed as MULTIU18HP230V1DONon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Friedrich vs Gree: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Friedrich (median, middle 50%)
  • Gree (median, middle 50%)
Heating capacity, % of its 47°F maximum72%70%COP at maximum capacity2.001.82

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
Friedrich: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F25100%100%100%100%100%
Friedrich, 17°F2565%72%79%83%93%
Friedrich, 5°F2550%59%72%75%77%
Friedrich: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F252.242.72.93.213.51
Friedrich, 17°F251.9222.282.42.72
Friedrich, 5°F251.821.8622.012.25
Gree: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Gree, 47°F283100%100%100%100%100%
Gree, 17°F28368%73%83%88%95%
Gree, 5°F28356%61%70%75%82%
Gree: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Gree, 47°F2832.612.943.173.283.49
Gree, 17°F28322.082.232.382.44
Gree, 5°F2831.761.81.821.912.12

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter