Skip to content

Friedrich vs Gree heat pumps

Measured against models of the same size and duct type, Gree scores higher on 5 of the 6 ratings. Friedrich has 192 outdoor models, Gree has 729 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Friedrich and Gree on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Gree scores higher on 5 of the 6 ratings.
  • Friedrich
  • Gree
  • Other ranked manufacturers
FriedrichGree

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFriedrichGree
Efficiency index40%median — · 28th ranked54%median — · 14th ranked
COP at 5°F46% (higher)median 1.99 · 22nd ranked44% (higher)median 1.94 · 25th ranked
Capacity retention at 5°F36%median 51% · 27th ranked57%median 77% · 9th ranked
HSPF232%median 7.5 · 28th ranked43%median 9.0 · 23rd ranked
SEER235%median 15.2 · 28th ranked60%median 20.4 · 6th ranked
EER238%median 10.6 · 29th ranked59%median 12.0 · 10th ranked
Heating capacity at 5°F34%median 17,400 Btu/h · 28th ranked56%median 17,000 Btu/h · 13th ranked
Outdoor models192729
AHRI certifications6,8005,398

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFriedrichGree
CEE 2025 Tier 1 (Split ASHP)28.1%54 models81.3%593 models
CEE 2026 Tier 1 (Split ASHP)25%48 models80.1%584 models
CEE Advanced Tier (Split ASHP)0.5%1 models5.5%40 models
Xcel Energy Colorado cold-climate ASHP (2025)22.4%43 models80.1%584 models
DOE Cold Climate Heat Pump Challenge0.5%1 models5.5%40 models
ENERGY STAR Cold Climate21.9%42 models65.4%477 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • Friedrich
  • Gree
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFriedrichGree
Ducted, up to 1.5 tons20 · index 31%102 · index 65%
Ducted, 2 tons23 · index 32%69 · index 56%
Ducted, 2.5 to 3 tons47 · index 36%139 · index 52%
Ducted, 3.5 to 4.5 tons59 · index 41%121 · index 55%
Ducted, 5 tons and up22 · index 36%4 · index 60%
Non-ducted, up to 1.5 tons20 · index 57%316 · index 52%
Non-ducted, 2 tons5 · index 52%83 · index 56%
Non-ducted, 2.5 to 3 tons4 · index 48%81 · index 48%
Non-ducted, 3.5 to 4.5 tons2 · index 47%49 · index 47%
Non-ducted, 5 tons and upNone3 · index 66%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFriedrichCold-climate score, best modelGreeCold-climate score, best model
Ducted, up to 1.5 tons73.8(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D6 of 22 models qualify · AHRI 21750565785.9(50 is the typical model of its size class) (higher)SPHP-Z-V018BBwith ducted air handler AIRH-Z-V018V06C91 of 101 models qualify · AHRI 216497962
Ducted, 2 tons70.9(50 is the typical model of its size class)RD17AY24AJVCwith ducted air handler FRH2VY2417STACN5 of 21 models qualify · AHRI 21912594877.1(50 is the typical model of its size class) (higher)MHPC-H-024BSBwith ducted air handler MDUC-H-024BBB71 of 86 models qualify · AHRI 216497934
Ducted, 2.5 to 3 tons78.4(50 is the typical model of its size class) (higher)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN7 of 47 models qualify · AHRI 21689124677.7(50 is the typical model of its size class)SPHP-Z-V036BBwith ducted air handler AIRH-Z-V036V12C77 of 123 models qualify · AHRI 216497965
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class)FPHFR48A3Dwith ducted air handler FPHFA48A3D11 of 59 models qualify · AHRI 21750887288.7(50 is the typical model of its size class) (higher)GUD60W2/NHE-D(U)with ducted air handler HND60A/NHA-OAlso sold as Tosot TUH60-48D32E2O; also listed as FXU60HP230V1R32AO, HW60/NHE-D68 of 121 models qualify · AHRI 218043371
Ducted, 5 tons and up78.1(50 is the typical model of its size class) (higher)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR801V1255A24UHN1 of 22 models qualify · AHRI 21832811066.7(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)2 of 4 models qualify · AHRI 216772305
Non-ducted, up to 1.5 tons83.4(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 21423240890.4(50 is the typical model of its size class) (higher)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB298 of 316 models qualify · AHRI 216497938
Non-ducted, 2 tons76.9(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 21662615585.7(50 is the typical model of its size class) (higher)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB68 of 83 models qualify · AHRI 216497919
Non-ducted, 2.5 to 3 tons59.0(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 21669960877.8(50 is the typical model of its size class) (higher)GWHD(36)ND6MOAlso sold as Tosot TM36H32MO, Kinghome KM36X6O, Tosot MZ-COSMO36/O, Tosot TM36D6MO and 6 more; also listed as MUL36HP230V1R32AO, GS4M36HP230V1MO, GWHD(36)ND6CO74 of 81 models qualify · AHRI 214931589
Non-ducted, 3.5 to 4.5 tons49.8(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 21669960967.0(50 is the typical model of its size class) (higher)GWHD(42)ND6MOAlso sold as Tosot TM42H32MO, Kinghome KM42X6O, Tosot TM42D6MO, Tosot TMSCI7H4R42 and 5 more; also listed as MUL42HP230V1R32AO, GS5M42HP230V1MO31 of 49 models qualify · AHRI 214931590
Non-ducted, 5 tons and upNo models in this size class53.8(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)2 of 3 models qualify · AHRI 216772249

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFriedrichAll-around score, best modelGreeAll-around score, best model
Ducted, up to 1.5 tons68.5(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D21 of 21 models have all five ratings · AHRI 21750565784.1(50 is the typical model of its size class) (higher)TWH09AUC25R32A1DOwith ducted air handler TM09R32SFDI101 of 101 models have all five ratings · AHRI 218214175
Ducted, 2 tons75.5(50 is the typical model of its size class)FRP19AY24AJVCwith ducted air handler FRHMVY3621MEACA21 of 21 models have all five ratings · AHRI 21573959382.7(50 is the typical model of its size class) (higher)A7CP21V24P-**Awith ducted air handler 7AH2AE24PX-75 of 78 models have all five ratings · AHRI 217465953
Ducted, 2.5 to 3 tons84.9(50 is the typical model of its size class) (higher)FRP19AY36AJVCwith ducted air handler FRHMVY3621MEACA34 of 47 models have all five ratings · AHRI 21558444079.7(50 is the typical model of its size class)A7CP21V36P-**Awith ducted air handler 7AH1AV42PX-130 of 130 models have all five ratings · AHRI 217465906
Ducted, 3.5 to 4.5 tons84.3(50 is the typical model of its size class)FRP19AY48AJVCwith ducted air handler FRHMVY4821SEACA37 of 56 models have all five ratings · AHRI 21558444185.3(50 is the typical model of its size class) (higher)MHPC-H-048BMB117 of 121 models have all five ratings · AHRI 216497951
Ducted, 5 tons and up70.6(50 is the typical model of its size class) (higher)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN16 of 26 models have all five ratings · AHRI 21832840667.2(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 216371303
Non-ducted, up to 1.5 tons85.1(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 21423240893.3(50 is the typical model of its size class) (higher)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB316 of 316 models have all five ratings · AHRI 216497938
Non-ducted, 2 tons63.6(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 21409182087.8(50 is the typical model of its size class) (higher)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB79 of 83 models have all five ratings · AHRI 216497919
Non-ducted, 2.5 to 3 tons64.9(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 21579283975.5(50 is the typical model of its size class) (higher)GMV-V36WL/NHC-T(U)Also sold as Tosot TMV-V36WL/NHC-T(U)81 of 81 models have all five ratings · AHRI 217123443
Non-ducted, 3.5 to 4.5 tons49.4(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 21669960968.7(50 is the typical model of its size class) (higher)MHPC-H-048BMB48 of 49 models have all five ratings · AHRI 216497952
Non-ducted, 5 tons and upNo models in this size class69.5(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)3 of 3 models have all five ratings · AHRI 216772249

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFriedrichGree
COP at 5°Fbeats 97% · 2.40FSHSR18B3BAlso listed as FSHSR18B3DNon-ducted, up to 1.5 tonsbeats 99% · 2.35GFH60DCXL-D6DND4C/ONon-ducted, 3.5 to 4.5 tons
Capacity retention at 5°Fbeats 100% · 133%FPHFR09A3DDucted, up to 1.5 tonsbeats 99% · 103%SPHP-X-I060BDucted, 3.5 to 4.5 tons
HSPF2beats 91% · 9.5FRP17AY60AJVCDucted, 5 tons and upbeats 98% · 13.9MHPC-H-009BSBNon-ducted, up to 1.5 tons
SEER2beats 98% · 21.0FRP19AY36AJVCDucted, 2.5 to 3 tonsbeats 100% · 24.5GWH18AVEXF-D6DNA1A/OAlso sold as Kinghome KW18XQ29SDO, Tosot TW18HAY32A1DO, Tosot TW18HAY32A1DOC, Tosot TWH18AD32AO and 1 more; also listed as GWH18AVEXF-D6DNA1B/ODucted, up to 1.5 tons
EER2beats 96% · 13.0RD18AY36AJVCDucted, 2.5 to 3 tonsbeats 100% · 14.5BH714S18P-**ADucted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tonsbeats 98% · 19,600 Btu/hGS18HP230V1CLODucted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Friedrich vs Gree: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Friedrich (median, middle 50%)
  • Gree (median, middle 50%)
Heating capacity, % of its 47°F maximum71%70%COP at maximum capacity2.001.95

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Friedrich: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F44100%100%100%100%100%
Friedrich, 17°F4460%65%68%84%92%
Friedrich, 5°F4457%62%71%74%85%
Friedrich: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F442.82.93.083.213.46
Friedrich, 17°F442.072.22.42.52.51
Friedrich, 5°F441.891.922.092.1
Gree: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Gree, 47°F550100%100%100%100%100%
Gree, 17°F55068%73%79%87%95%
Gree, 5°F55058%63%70%76%94%
Gree: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Gree, 47°F5502.873.173.283.423.61
Gree, 17°F5501.992.082.252.42.56
Gree, 5°F5501.81.831.952.052.14

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter