Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Friedrich vs Trane heat pumps
Measured against models of the same size and duct type, Trane scores higher on 4 of the 6 ratings. Friedrich has 117 outdoor models, Trane has 309 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Friedrich
- Trane
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Friedrich | Trane |
|---|---|---|
| Efficiency index | 46%median — · 25th ranked | 52%median — · 18th ranked |
| COP at 5°F | 58%median 2.10 · 9th ranked | 69%median 2.18 · 3rd ranked |
| Capacity retention at 5°F | 45% (higher)median 61% · 20th ranked | 43% (higher)median 63% · 22nd ranked |
| HSPF2 | 31%median 7.5 · 26th ranked | 35%median 7.8 · 25th ranked |
| SEER2 | 36%median 15.2 · 26th ranked | 36%median 15.2 · 25th ranked |
| EER2 | 39%median 10.6 · 26th ranked | 65%median 11.7 · 4th ranked |
| Heating capacity at 5°F | 39%median 15,600 Btu/h · 25th ranked | 41%median 20,000 Btu/h · 23rd ranked |
| Outdoor models | 117 | 309 |
| AHRI certifications | 3,083 | 102,516 |
Share of models meeting each standard
| Standard | Friedrich | Trane |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 37.6%44 models | 31.4%97 models |
| CEE 2026 Tier 1 (Split ASHP) | 37.6%44 models | 26.2%81 models |
| CEE Advanced Tier (Split ASHP) | 1.7%2 models | 0.3%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.6%37 models | 22%68 models |
| DOE Cold Climate Heat Pump Challenge | 1.7%2 models | 0.3%1 models |
| ENERGY STAR Cold Climate | 28.2%33 models | 10%31 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Friedrich
- Trane
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Friedrich | Trane |
|---|---|---|
| Ducted, up to 1.5 tons | 21 · index 27% | 25 · index 35% |
| Ducted, 2 tons | 16 · index 45% | 53 · index 50% |
| Ducted, 2.5–3 tons | 22 · index 52% | 86 · index 54% |
| Ducted, 3.5–4.5 tons | 28 · index 47% | 108 · index 60% |
| Ducted, 5 tons and up | 7 · index — | 7 · index 46% |
| Non-ducted, up to 1.5 tons | 19 · index 55% | 23 · index 38% |
| Non-ducted, 2 tons | 6 · index 47% | 7 · index 54% |
| Non-ducted, 2.5–3 tons | 6 · index 61% | 10 · index 59% |
| Non-ducted, 3.5–4.5 tons | 1 · index 45% | 1 · index 19% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FriedrichCold-climate score, best model | TraneCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.9(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A4 of 20 models qualify · AHRI 205048198 | 62.8(50 is the typical model of its size class) (higher)4A6H4018N1with ducted air handler AE(D,N,U)+CM30B34+TDR12 of 22 models qualify · AHRI 212361095 |
| Ducted, 2 tons | 74.7(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU5 of 17 models qualify · AHRI 213829710 | 75.3(50 is the typical model of its size class) (higher)4TXD2036A10NU**with ducted air handler F,PE*G3493022 of 55 models qualify · AHRI 212396569 |
| Ducted, 2.5–3 tons | 80.6(50 is the typical model of its size class)FRP18AZ36AJVCwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU5 of 22 models qualify · AHRI 213829722 | 82.2(50 is the typical model of its size class) (higher)4TWV0X36A1with indoor coil D(A,C,E)48C34+TDR and furnace S9V2C080U5PSC+RP32 of 87 models qualify · AHRI 215472282 |
| Ducted, 3.5–4.5 tons | 76.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR962V1005A21M47 of 28 models qualify · AHRI 214279028 | 84.1(50 is the typical model of its size class) (higher)4A6C7048A3with ducted air handler 4PX*DU60BS3+P0V0C000M50SCAlso listed as 4A6C7048A417 of 108 models qualify · AHRI 213867310 |
| Ducted, 5 tons and up | None on this board (0 of 7 models qualify) | None on this board (0 of 7 models qualify) |
| Non-ducted, up to 1.5 tons | 78.4(50 is the typical model of its size class)FPHFR09A3Awith ductless indoor unit FPHFC09A3B18 of 19 models qualify · AHRI 205048197 | 80.1(50 is the typical model of its size class) (higher)4TXK3809B10NU**with ductless indoor unit 4MXW3809B10NU16 of 23 models qualify · AHRI 204340354 |
| Non-ducted, 2 tons | 72.0(50 is the typical model of its size class)FPHFR24A3Awith ductless indoor unit FPHFC24A3B5 of 6 models qualify · AHRI 205123805 | 76.1(50 is the typical model of its size class) (higher)4TXM2124A13N0**4 of 7 models qualify · AHRI 210435406 |
| Non-ducted, 2.5–3 tons | 77.2(50 is the typical model of its size class) (higher)FPHFR36A3Awith ductless indoor unit FPHSC36A3B2 of 6 models qualify · AHRI 205150421 | 73.7(50 is the typical model of its size class)4TXM2142A15N0**7 of 10 models qualify · AHRI 210435409 |
| Non-ducted, 3.5–4.5 tons | 41.9(50 is the typical model of its size class) (higher)FPHMR42A3A1 of 1 models qualify · AHRI 205141513 | 31.6(50 is the typical model of its size class)4TXM2336A15NU**1 of 1 models qualify · AHRI 206319651 |
All-around best
| Size and duct type | FriedrichAll-around score, best model | TraneAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 57.7(50 is the typical model of its size class) (higher)FPHFR09A3Awith ducted air handler FPHFD09A3A14 of 20 models have all five ratings · AHRI 205048198 | 52.8(50 is the typical model of its size class)4TWR5018N1with indoor coil D(A,C,E)30A34+TDR and furnace *UD2B060A9V3Also sold as American Standard 4A6H5018N120 of 23 models have all five ratings · AHRI 212367293 |
| Ducted, 2 tons | 83.5(50 is the typical model of its size class) (higher)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU12 of 17 models have all five ratings · AHRI 213829710 | 77.1(50 is the typical model of its size class)4TWV8X24A1with indoor coil D(A,C,E)36C34+TDR and furnace S9V2B060U4PSB+RP42 of 52 models have all five ratings · AHRI 215472297 |
| Ducted, 2.5–3 tons | 86.1(50 is the typical model of its size class) (higher)FRP18AZ36AJVCwith ducted air handler FRHMVZ6021SEACA12 of 22 models have all five ratings · AHRI 213087287 | 85.1(50 is the typical model of its size class)4TWV0X36A1with indoor coil D(A,C,E)48C34+TDR and furnace S9V2C080U5PSC+RP69 of 83 models have all five ratings · AHRI 215472282 |
| Ducted, 3.5–4.5 tons | 80.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR802V1005A21UH17 of 27 models have all five ratings · AHRI 214610153 | 86.2(50 is the typical model of its size class) (higher)4A6C7048A3with ducted air handler 4PX*DU60BS3+P0V0C000M50SCAlso listed as 4A6C7048A490 of 114 models have all five ratings · AHRI 213867310 |
| Ducted, 5 tons and up | 70.1(50 is the typical model of its size class)FWP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace FR97MV1005A21DH1 of 8 models have all five ratings · AHRI 213841738 | 81.0(50 is the typical model of its size class) (higher)4TWL9060A1with indoor coil TEM8B0C60V51+TDR and furnace N/AAlso sold as American Standard 4A6L9060A16 of 7 models have all five ratings · AHRI 207820927 |
| Non-ducted, up to 1.5 tons | 85.1(50 is the typical model of its size class)MRH09Y3JAwith ductless indoor unit MWH09Y3JA19 of 19 models have all five ratings · AHRI 201763897 | 88.7(50 is the typical model of its size class) (higher)4TXK3809B10NU**with ductless indoor unit 4MXW3809B10NU21 of 23 models have all five ratings · AHRI 204340354 |
| Non-ducted, 2 tons | 67.5(50 is the typical model of its size class)FPHMR24A3A6 of 6 models have all five ratings · AHRI 204101246 | 71.5(50 is the typical model of its size class) (higher)4TXM2124A13N0**5 of 7 models have all five ratings · AHRI 210435406 |
| Non-ducted, 2.5–3 tons | 69.4(50 is the typical model of its size class)FPHMR36A3A2 of 6 models have all five ratings · AHRI 204101247 | 70.2(50 is the typical model of its size class) (higher)4TXM2142A15N0**7 of 10 models have all five ratings · AHRI 210435409 |
| Non-ducted, 3.5–4.5 tons | 44.5(50 is the typical model of its size class) (higher)FPHMR42A3A1 of 1 models have all five ratings · AHRI 205141512 | 18.7(50 is the typical model of its size class)4TXM2336A15NU**1 of 1 models have all five ratings · AHRI 206319651 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Friedrich | Trane |
|---|---|---|
| COP at 5°F | beats 97% · 2.80WFPU17Z243CDucted, up to 1.5 tons | beats 100% · 3.604A6C7048A3Also listed as 4A6C7048A4Ducted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 100% · 105%FRP18AZ48AJVCDucted, 3.5–4.5 tons | beats 100% · 120%4A6H4042N1Ducted, 3.5–4.5 tons |
| HSPF2 | beats 83% · 9.5FPHFR36A3ADucted, 2.5–3 tons | beats 88% · 11.04TXK3809B10NU**Non-ducted, up to 1.5 tons |
| SEER2 | beats 96% · 27.5MRH09Y3JANon-ducted, up to 1.5 tons | beats 99% · 19.04TWL9060A1Also sold as American Standard 4A6L9060A1Ducted, 5 tons and up |
| EER2 | beats 93% · 15.5MRH09Y3JANon-ducted, up to 1.5 tons | beats 99% · 16.64TXK3809B10NU**Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 100% · 43,500 Btu/hFRP18AZ36AJVCDucted, 2.5–3 tons | beats 100% · 34,000 Btu/hE4HL5018A1000ADucted, up to 1.5 tons |