Friedrich vs Trane heat pumps
Measured against models of the same size and duct type, Trane scores higher on 6 of the 6 ratings. Friedrich has 192 outdoor models, Trane has 370 outdoor models.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Friedrich
- Trane
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Friedrich | Trane |
|---|---|---|
| Efficiency index | 40%median — · 28th ranked | 50%median — · 19th ranked |
| COP at 5°F | 46%median 1.99 · 22nd ranked | 69%median 2.27 · 1st ranked |
| Capacity retention at 5°F | 36%median 51% · 27th ranked | 43%median 65% · 25th ranked |
| HSPF2 | 32%median 7.5 · 28th ranked | 35%median 7.5 · 27th ranked |
| SEER2 | 35%median 15.2 · 28th ranked | 40%median 15.5 · 26th ranked |
| EER2 | 38%median 10.6 · 29th ranked | 67%median 11.7 · 3rd ranked |
| Heating capacity at 5°F | 34%median 17,400 Btu/h · 28th ranked | 44%median 21,400 Btu/h · 25th ranked |
| Outdoor models | 192 | 370 |
| AHRI certifications | 6,800 | 93,740 |
Share of models meeting each standard
| Standard | Friedrich | Trane |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 28.1%54 models | 38.6%143 models |
| CEE 2026 Tier 1 (Split ASHP) | 25%48 models | 36.2%134 models |
| CEE Advanced Tier (Split ASHP) | 0.5%1 models | 2.4%9 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 22.4%43 models | 25.4%94 models |
| DOE Cold Climate Heat Pump Challenge | 0.5%1 models | 2.4%9 models |
| ENERGY STAR Cold Climate | 21.9%42 models | 16.8%62 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Friedrich
- Trane
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Friedrich | Trane |
|---|---|---|
| Ducted, up to 1.5 tons | 20 · index 31% | 19 · index 49% |
| Ducted, 2 tons | 23 · index 32% | 40 · index 42% |
| Ducted, 2.5 to 3 tons | 47 · index 36% | 108 · index 50% |
| Ducted, 3.5 to 4.5 tons | 59 · index 41% | 133 · index 53% |
| Ducted, 5 tons and up | 22 · index 36% | 46 · index 50% |
| Non-ducted, up to 1.5 tons | 20 · index 57% | 15 · index 55% |
| Non-ducted, 2 tons | 5 · index 52% | 4 · index 44% |
| Non-ducted, 2.5 to 3 tons | 4 · index 48% | 7 · index 56% |
| Non-ducted, 3.5 to 4.5 tons | 2 · index 47% | 3 · index 63% |
| Non-ducted, 5 tons and up | None | 2 · index 68% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FriedrichCold-climate score, best model | TraneCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.8(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D6 of 22 models qualify · AHRI 217505657 | 92.7(50 is the typical model of its size class) (higher)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB6 of 21 models qualify · AHRI 216794262 |
| Ducted, 2 tons | 70.9(50 is the typical model of its size class)RD17AY24AJVCwith ducted air handler FRH2VY2417STACN5 of 21 models qualify · AHRI 219125948 | 77.9(50 is the typical model of its size class) (higher)5A6H7024A1with ducted air handler CM24D3J+TDR13 of 38 models qualify · AHRI 217155223 |
| Ducted, 2.5 to 3 tons | 78.4(50 is the typical model of its size class)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN7 of 47 models qualify · AHRI 216891246 | 95.1(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5TAMXD06AV41Also sold as American Standard 5A5V0X36A126 of 108 models qualify · AHRI 218868829 |
| Ducted, 3.5 to 4.5 tons | 83.9(50 is the typical model of its size class)FPHFR48A3Dwith ducted air handler FPHFA48A3D11 of 59 models qualify · AHRI 217508872 | 92.8(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP39 of 133 models qualify · AHRI 216794596 |
| Ducted, 5 tons and up | 78.1(50 is the typical model of its size class)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR801V1255A24UHN1 of 22 models qualify · AHRI 218328110 | 81.8(50 is the typical model of its size class) (higher)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA2 of 46 models qualify · AHRI 218451025 |
| Non-ducted, up to 1.5 tons | 83.4(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 214232408 | 70.1(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models qualify · AHRI 218067082 |
| Non-ducted, 2 tons | 76.9(50 is the typical model of its size class) (higher)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 216626155 | 39.6(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models qualify · AHRI 215385437 |
| Non-ducted, 2.5 to 3 tons | 59.0(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 216699608 | 74.4(50 is the typical model of its size class) (higher)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA5 of 7 models qualify · AHRI 218451026 |
| Non-ducted, 3.5 to 4.5 tons | 49.8(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 216699609 | 67.5(50 is the typical model of its size class) (higher)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models qualify · AHRI 218451027 |
| Non-ducted, 5 tons and up | No models in this size class | 64.2(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models qualify · AHRI 218451028 |
All-around best
| Size and duct type | FriedrichAll-around score, best model | TraneAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 68.5(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D21 of 21 models have all five ratings · AHRI 217505657 | 85.1(50 is the typical model of its size class) (higher)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRP18 of 18 models have all five ratings · AHRI 216794699 |
| Ducted, 2 tons | 75.5(50 is the typical model of its size class)FRP19AY24AJVCwith ducted air handler FRHMVY3621MEACA21 of 21 models have all five ratings · AHRI 215739593 | 81.5(50 is the typical model of its size class) (higher)5A6V0X24A1with indoor coil 5PX*BD06AS3 and furnace S9V2B060D3VSB+VCKIT28 of 28 models have all five ratings · AHRI 218036320 |
| Ducted, 2.5 to 3 tons | 84.9(50 is the typical model of its size class)FRP19AY36AJVCwith ducted air handler FRHMVY3621MEACA34 of 47 models have all five ratings · AHRI 215584440 | 95.7(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5PX*D010AS3+P0V0D000M50SD+LRPAlso sold as American Standard 5A5V0X36A175 of 111 models have all five ratings · AHRI 218868823 |
| Ducted, 3.5 to 4.5 tons | 84.3(50 is the typical model of its size class)FRP19AY48AJVCwith ducted air handler FRHMVY4821SEACA37 of 56 models have all five ratings · AHRI 215584441 | 89.2(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP107 of 143 models have all five ratings · AHRI 216794476 |
| Ducted, 5 tons and up | 70.6(50 is the typical model of its size class)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN16 of 26 models have all five ratings · AHRI 218328406 | 74.8(50 is the typical model of its size class) (higher)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA9 of 46 models have all five ratings · AHRI 218451025 |
| Non-ducted, up to 1.5 tons | 85.1(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 214232408 | 73.9(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models have all five ratings · AHRI 218067082 |
| Non-ducted, 2 tons | 63.6(50 is the typical model of its size class) (higher)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 214091820 | 51.4(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models have all five ratings · AHRI 215385437 |
| Non-ducted, 2.5 to 3 tons | 64.9(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 215792839 | 76.7(50 is the typical model of its size class) (higher)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA7 of 7 models have all five ratings · AHRI 218451026 |
| Non-ducted, 3.5 to 4.5 tons | 49.4(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 216699609 | 73.8(50 is the typical model of its size class) (higher)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models have all five ratings · AHRI 218451027 |
| Non-ducted, 5 tons and up | No models in this size class | 68.0(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models have all five ratings · AHRI 218451028 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Friedrich | Trane |
|---|---|---|
| COP at 5°F | beats 97% · 2.40FSHSR18B3BAlso listed as FSHSR18B3DNon-ducted, up to 1.5 tons | beats 100% · 3.205TWR4036A1Ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 100% · 133%FPHFR09A3DDucted, up to 1.5 tons | beats 100% · 136%5A6H7036A1Ducted, 2.5 to 3 tons |
| HSPF2 | beats 91% · 9.5FRP17AY60AJVCDucted, 5 tons and up | beats 100% · 13.53TXK2224AF00HAAAlso listed as 3TXK2236AF00HAA, 3TVHS036SF000AADucted, 2.5 to 3 tons |
| SEER2 | beats 98% · 21.0FRP19AY36AJVCDucted, 2.5 to 3 tons | beats 99% · 21.65TWV0X36A1Also sold as American Standard 5A6V0X36A1Ducted, 2.5 to 3 tons |
| EER2 | beats 96% · 13.0RD18AY36AJVCDucted, 2.5 to 3 tons | beats 99% · 13.55TCV0X36A1Also sold as American Standard 5A5V0X36A1Ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tons | beats 100% · 27,200 Btu/h5TWV0X24A1Ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Friedrich (median, middle 50%)
- Trane (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Friedrich, 47°F | 44 | 100% | 100% | 100% | 100% | 100% |
| Friedrich, 17°F | 44 | 60% | 65% | 68% | 84% | 92% |
| Friedrich, 5°F | 44 | 57% | 62% | 71% | 74% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Friedrich, 47°F | 44 | 2.8 | 2.9 | 3.08 | 3.21 | 3.46 |
| Friedrich, 17°F | 44 | 2.07 | 2.2 | 2.4 | 2.5 | 2.51 |
| Friedrich, 5°F | 44 | 1.89 | 1.9 | 2 | 2.09 | 2.1 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Trane, 47°F | 52 | 100% | 100% | 100% | 100% | 100% |
| Trane, 17°F | 52 | 71% | 73% | 85% | 90% | 93% |
| Trane, 5°F | 52 | 57% | 64% | 70% | 73% | 76% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Trane, 47°F | 52 | 2.47 | 2.92 | 3.14 | 3.66 | 4 |
| Trane, 17°F | 52 | 2.14 | 2.2 | 2.4 | 2.5 | 2.6 |
| Trane, 5°F | 52 | 1.8 | 1.96 | 2.1 | 2.2 | 2.22 |
Source: NEEP ccASHP list · as of