Both views use the same certified data. This device remembers your choice.
Fujitsu vs Hisense: heat pump ratings compared
Against heat pumps of the same size and type, a typical Fujitsu model beats 58% and a typical Hisense model 46%. Fujitsu rates higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
Fujitsu
58%
of similar heat pumps beaten by its typical model
Above average164 models listed
Hisense
46%
of similar heat pumps beaten by its typical model
About average160 models listed
- Efficiency on a 5°F dayCOP at 5°FFujitsu: Beats 71%Hisense: Beats 31%
- Heating power kept at 5°FCapacity at 5°F vs 47°FFujitsu: Beats 65%Hisense: Beats 47%
- Winter-long heating efficiencyHSPF2Fujitsu: Beats 53%Hisense: Beats 42%
- Summer-long cooling efficiencySEER2Fujitsu: Beats 46%Hisense: Beats 50%
- Hot-day cooling efficiencyEER2Fujitsu: Beats 49%Hisense: Beats 56%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Fujitsu
- 38%
- Hisense
- 74%
Xcel CC
- Fujitsu
- 34%
- Hisense
- 63%
CEE Advanced
- Fujitsu
- 6%
- Hisense
- 0%
ENERGY STAR CC
- Fujitsu
- 28%
- Hisense
- 44%
Top cold-climate picks, ducted 3.5 to 4.5 tons
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
Fujitsu
- 1AOU42RGLXwith ducted air handler ARU42RGLXFujitsu3.5 tons · 42,000 Btu/h · DuctedKeeps 75% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.28 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.8 (HSPF2)
- Top 10%
- 2AOUH48LMAH1with ducted air handler AMUG48LMASFujitsu4 tons · 45,500 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.92 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.0 (HSPF2)
- Top 10%
- 3FOP1848MJAZCAwith indoor coil FCCA6021SZEA and furnace FF96TV510021M4S*AFujitsu3.5 tons · 44,500 Btu/h · DuctedKeeps 103% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 103% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 8.5 (HSPF2)
- Good
Hisense
- 1AUWR-60U3SP2with ducted air handler L(E,G)M60I4Hisense4.5 tons · 56,000 Btu/h · DuctedKeeps 71% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.60 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 8.5 (HSPF2)
- Good
- 2AUWR-48U3SPwith ducted air handler HE49960+TDHisense3.5 tons · 41,000 Btu/h · DuctedKeeps 86% of its heat at 5°FMeets Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 86% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.94 (COP at 5°F)
- Good
- Seasonal efficiency
- 8.6 (HSPF2)
- Good
- 3AMW5-42U3STAHisense3.5 tons · 41,000 Btu/h · DuctedKeeps 88% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 88% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.84 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 8.8 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view