Skip to content

Fujitsu vs Mitsubishi Electric: heat pump ratings compared

Against heat pumps of the same size and type, a typical Fujitsu model beats 58% and a typical Mitsubishi Electric model 65%. Mitsubishi Electric rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

Fujitsu

58%

of similar heat pumps beaten by its typical model

Above average

164 models listed

Mitsubishi Electric

65%

of similar heat pumps beaten by its typical model

Well above average

400 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FFujitsu: Beats 71%Mitsubishi Electric: Beats 68%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FFujitsu: Beats 65%Mitsubishi Electric: Beats 54%
  • Winter-long heating efficiencyHSPF2Fujitsu: Beats 53%Mitsubishi Electric: Beats 71%
  • Summer-long cooling efficiencySEER2Fujitsu: Beats 46%Mitsubishi Electric: Beats 63%
  • Hot-day cooling efficiencyEER2Fujitsu: Beats 49%Mitsubishi Electric: Beats 64%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Fujitsu
    38%
    Mitsubishi Electric
    65%
  • Xcel CC

    Fujitsu
    34%
    Mitsubishi Electric
    52%
  • CEE Advanced

    Fujitsu
    6%
    Mitsubishi Electric
    6%
  • ENERGY STAR CC

    Fujitsu
    28%
    Mitsubishi Electric
    36%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

Fujitsu

  1. 1FOP1836MJAZCAwith indoor coil FCCA6021SZEA and furnace FF75173LT80XFujitsu3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 80.4Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    119% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    8.5 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    87.1score / 100Heating 80 · Cooling 94
  2. 2AOU36RLXFZHFujitsu3 tons · 35,200 Btu/h · DuctedCold-climate pick, score 77.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    101% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.02 (COP at 5°F)
    Good
    Winter efficiency
    8.7 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    80.3score / 100Heating 78 · Cooling 83
  3. 3AOUH30LUAH1with ducted air handler ARUH30LUASFujitsu2.5 tons · 28,600 Btu/h · DuctedCold-climate pick, score 70.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    110% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.76 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    18.3 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    77.5score / 100Heating 71 · Cooling 84

Mitsubishi Electric

  1. 1PUZ-HA36NKA1***with ducted air handler PVA-A36AAMitsubishi ElectricAlso sold as Trane / Mitsubishi Electric PUZ-HA36NKA, Trane / Mitsubishi Electric TRUZH0361KA00, Trane / Mitsubishi Electric TRUZH0361KA00NA, Trane / Mitsubishi Electric TRUZH0361KA103 tons · 33,000 Btu/h · DuctedCold-climate pick, score 84.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    95% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Top 10%
    Cooling efficiency
    18.2 (SEER2)
    Great
    Hot-day cooling
    13.2 (EER2)
    Top 10%
    87.2score / 100Heating 85 · Cooling 90
  2. 2PUZ-HA36NKA*with ducted air handler PEAD-A36AA9Mitsubishi ElectricAlso sold as Trane / Mitsubishi Electric TRUZH0361KA3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 82.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    95% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.01 (COP at 5°F)
    Good
    Winter efficiency
    9.3 (HSPF2)
    Great
    Cooling efficiency
    17.6 (SEER2)
    Great
    Hot-day cooling
    12.7 (EER2)
    Top 10%
    84.3score / 100Heating 82 · Cooling 87
  3. 3PUZ-HA30NKA1***with ducted air handler PVA-A30AAMitsubishi ElectricAlso sold as Trane / Mitsubishi Electric TRUZH0301KA00, Trane / Mitsubishi Electric TRUZH0301KA00NA2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 78.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    94% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.17 (COP at 5°F)
    Great
    Winter efficiency
    8.7 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    83.5score / 100Heating 79 · Cooling 88

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter