Fujitsu vs York heat pumps
Measured against models of the same size and duct type, Fujitsu scores higher on 5 of the 6 ratings. Fujitsu has 164 outdoor models, York has 179 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Fujitsu
- York
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Fujitsu | York |
|---|---|---|
| Efficiency index | 58% (higher)median — · 9th ranked | 51% (higher)median — · 21st ranked |
| COP at 5°F | 70% (higher)median 2.10 · 2nd ranked | 69% (higher)median 2.20 · 5th ranked |
| Capacity retention at 5°F | 65% (higher)median 81% · 3rd ranked | 50% (higher)median 69% · 18th ranked |
| HSPF2 | 53% (higher)median 8.5 · 12th ranked | 37% (higher)median 7.7 · 23rd ranked |
| SEER2 | 46% (higher)median 16.6 · 19th ranked | 38% (higher)median 15.2 · 24th ranked |
| EER2 | 49%median 11.5 · 17th ranked | 57%median 11.0 · 9th ranked |
| Heating capacity at 5°F | 62% (higher)median 20,800 Btu/h · 5th ranked | 49% (higher)median 24,200 Btu/h · 17th ranked |
| Outdoor models | 164 | 179 |
| AHRI certifications | 765 | 65,299 |
Share of models meeting each standard
| Standard | Fujitsu | York |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 38.4%63 models | 26.3%47 models |
| CEE 2026 Tier 1 (Split ASHP) | 37.8%62 models | 26.3%47 models |
| CEE Advanced Tier (Split ASHP) | 6.1%10 models | 0.6%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 34.1%56 models | 25.7%46 models |
| DOE Cold Climate Heat Pump Challenge | 6.1%10 models | 0.6%1 models |
| ENERGY STAR Cold Climate | 28%46 models | 2.2%4 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Fujitsu
- York
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Fujitsu | York |
|---|---|---|
| Ducted, up to 1.5 tons | 15 · index 39% | 8 · index 42% |
| Ducted, 2 tons | 14 · index 53% | 17 · index 47% |
| Ducted, 2.5–3 tons | 36 · index 54% | 53 · index 51% |
| Ducted, 3.5–4.5 tons | 42 · index 51% | 71 · index 60% |
| Ducted, 5 tons and up | 12 · index 64% | 19 · index 50% |
| Non-ducted, up to 1.5 tons | 44 · index 74% | 9 · index 25% |
| Non-ducted, 2 tons | 9 · index 65% | 2 · index 41% |
| Non-ducted, 2.5–3 tons | 14 · index 59% | 6 · index 54% |
| Non-ducted, 3.5–4.5 tons | 5 · index 46% | 5 · index 46% |
| Non-ducted, 5 tons and up | 1 · index 18% | 2 · index 46% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FujitsuCold-climate score, best model | YorkCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 83.5(50 is the typical model of its size class) (higher)AOUH12LUAS1with ducted air handler ARUH12LUAS5 of 15 models qualify · AHRI 207334301 | 59.7(50 is the typical model of its size class)THF2B18S21with ducted air handler AE(D,N,U)+CM24D24+TDR7 of 8 models qualify · AHRI 214606310 |
| Ducted, 2 tons | 75.4(50 is the typical model of its size class) (higher)AOU24RLXFZH6 of 14 models qualify · AHRI 8033742 | 60.6(50 is the typical model of its size class)THE2B24T21with ducted air handler AX242BTA10 of 16 models qualify · AHRI 211634285 |
| Ducted, 2.5–3 tons | 86.6(50 is the typical model of its size class) (higher)AOUH30LUAS1with ducted air handler ARUH30LUAS12 of 36 models qualify · AHRI 211078837 | 83.8(50 is the typical model of its size class)HMH72B341with indoor coil CM36B36+TDR and furnace TM9V120D20MP1222 of 53 models qualify · AHRI 211628039 |
| Ducted, 3.5–4.5 tons | 83.5(50 is the typical model of its size class) (higher)AOU42RGLXwith ducted air handler ARU42RGLX7 of 42 models qualify · AHRI 202537550 | 77.7(50 is the typical model of its size class)RHP15048B21with ducted air handler L(E,G)M60A4Also sold as Champion Heating and Cooling THF2B48T2124 of 72 models qualify · AHRI 213612208 |
| Ducted, 5 tons and up | None on this board (0 of 12 models qualify) | 70.2(50 is the typical model of its size class)YMKE60BNJMFMO-X1 of 19 models qualify · AHRI 205739196 |
| Non-ducted, up to 1.5 tons | 96.9(50 is the typical model of its size class) (higher)AOUG12LZAS1with ductless indoor unit ASUG12LZAS28 of 44 models qualify · AHRI 204740068 | 64.2(50 is the typical model of its size class)DHS18CMB22S5 of 9 models qualify · AHRI 207616532 |
| Non-ducted, 2 tons | 89.0(50 is the typical model of its size class) (higher)AOUH24LMAS1with ductless indoor unit ASUH24LMAS6 of 9 models qualify · AHRI 206913028 | 66.1(50 is the typical model of its size class)DHS24CMB22S1 of 2 models qualify · AHRI 207616534 |
| Non-ducted, 2.5–3 tons | 90.6(50 is the typical model of its size class) (higher)AOU30RLXEHwith ductless indoor unit ASU30RLE11 of 14 models qualify · AHRI 8912454 | 60.8(50 is the typical model of its size class)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models qualify · AHRI 203994967 |
| Non-ducted, 3.5–4.5 tons | 75.3(50 is the typical model of its size class) (higher)AOU42RGLXwith ductless indoor unit AUU42RGLX2 of 5 models qualify · AHRI 202195867 | 31.6(50 is the typical model of its size class)DHS42CMB22S1 of 5 models qualify · AHRI 207616540 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | FujitsuAll-around score, best model | YorkAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 82.7(50 is the typical model of its size class) (higher)AOUH12LUAS1with ducted air handler ARUH12LUAS9 of 15 models have all five ratings · AHRI 207334301 | 57.1(50 is the typical model of its size class)YH2F18SB21with ducted air handler AE*S+CM24C24+TDR7 of 7 models have all five ratings · AHRI 216437405 |
| Ducted, 2 tons | 80.6(50 is the typical model of its size class) (higher)FOP1824MJAZCAwith indoor coil FCCA2421HZEA and furnace FF97MV306017DHS*A11 of 14 models have all five ratings · AHRI 209880024 | 77.1(50 is the typical model of its size class)YMSJYH024BAAND-1with ducted air handler YMSJXH024BAAN--517 of 17 models have all five ratings · AHRI 217734524 |
| Ducted, 2.5–3 tons | 87.2(50 is the typical model of its size class) (higher)FOP1836MJAZCAwith indoor coil FCCA6021SZEA and furnace FF75173LT80X22 of 36 models have all five ratings · AHRI 210868911 | 76.1(50 is the typical model of its size class)YMSJYH048BAAND-1with ducted air handler YMSJXH048BAAN--534 of 51 models have all five ratings · AHRI 217734526 |
| Ducted, 3.5–4.5 tons | 81.5(50 is the typical model of its size class)FOP1848MJAZCA1with ducted air handler FHRAVM6021SJZECA23 of 42 models have all five ratings · AHRI 208587413 | 83.7(50 is the typical model of its size class) (higher)YZV48B21with indoor coil XAMC48HE3N1+CC and furnace TM9V100C16MP1248 of 73 models have all five ratings · AHRI 211207031 |
| Ducted, 5 tons and up | 70.2(50 is the typical model of its size class)FOP1560TJAZNAwith indoor coil FCCN6024SZTA and furnace FF97MV510021DHS*A3 of 12 models have all five ratings · AHRI 212507664 | 75.1(50 is the typical model of its size class) (higher)YMKE60BNJMFMO-X12 of 20 models have all five ratings · AHRI 205739196 |
| Non-ducted, up to 1.5 tons | 96.2(50 is the typical model of its size class) (higher)AOUG12LZAS1with ductless indoor unit ASUG12LZAS29 of 44 models have all five ratings · AHRI 204740068 | 50.6(50 is the typical model of its size class)DHS18CMB22S9 of 9 models have all five ratings · AHRI 207616532 |
| Non-ducted, 2 tons | 86.5(50 is the typical model of its size class) (higher)AOUH24LUAS1with ductless indoor unit AUUH24LUAS7 of 9 models have all five ratings · AHRI 211078831 | 55.4(50 is the typical model of its size class)DHS24CMB22S2 of 2 models have all five ratings · AHRI 207616534 |
| Non-ducted, 2.5–3 tons | 79.2(50 is the typical model of its size class) (higher)AOU36RLXFZH12 of 14 models have all five ratings · AHRI 8908615 | 74.6(50 is the typical model of its size class)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models have all five ratings · AHRI 203994967 |
| Non-ducted, 3.5–4.5 tons | 65.1(50 is the typical model of its size class)AOU42RGLXwith ductless indoor unit AUU42RGLX5 of 5 models have all five ratings · AHRI 202195867 | 67.0(50 is the typical model of its size class) (higher)YVAHP048B21S*Also sold as Coleman CVAHP048B21S3 of 5 models have all five ratings · AHRI 203994968 |
| Non-ducted, 5 tons and up | 17.7(50 is the typical model of its size class)AOU60RLAVM41 of 1 models have all five ratings · AHRI 206347299 | 68.5(50 is the typical model of its size class) (higher)YVAHP060B21S*2 of 2 models have all five ratings · AHRI 203994964 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Fujitsu | York |
|---|---|---|
| COP at 5°F | beats 100% · 2.91AOU48RLAVS4Non-ducted, 3.5–4.5 tons | beats 100% · 3.44THE2B42T21Ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 100% · 158%AOU9RLFFNon-ducted, up to 1.5 tons | beats 100% · 149%THE2B18S21Ducted, up to 1.5 tons |
| HSPF2 | beats 98% · 13.4AOUG09LZAS1Non-ducted, up to 1.5 tons | beats 98% · 10.0YVAHP048B21S*Also sold as Coleman CVAHP048B21SDucted, 3.5–4.5 tons |
| SEER2 | beats 100% · 33.1AOUG09LZAS1Non-ducted, up to 1.5 tons | beats 96% · 18.0YMKE60BNJMFMO-XDucted, 5 tons and up |
| EER2 | beats 100% · 18.0AOUG09LZAS1Non-ducted, up to 1.5 tons | beats 100% · 16.7YVAHP048B21S*Also sold as Coleman CVAHP048B21SNon-ducted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 100% · 43,500 Btu/hFOP1836MJAZCADucted, 2.5–3 tons | beats 99% · 21,800 Btu/hDHS18CMB22SNon-ducted, up to 1.5 tons |