Fujitsu vs York heat pumps
Measured against models of the same size and duct type, York scores higher on 4 of the 6 ratings. Fujitsu has 180 outdoor models, York has 239 outdoor models.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Fujitsu
- York
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Fujitsu | York |
|---|---|---|
| Efficiency index | 53%median — · 16th ranked | 54%median — · 12th ranked |
| COP at 5°F | 58%median 2.08 · 12th ranked | 67%median 2.13 · 2nd ranked |
| Capacity retention at 5°F | 48%median 54% · 20th ranked | 53%median 70% · 14th ranked |
| HSPF2 | 45%median 7.5 · 19th ranked | 45%median 8.1 · 20th ranked |
| SEER2 | 44% (higher)median 15.2 · 22nd ranked | 40% (higher)median 16.0 · 25th ranked |
| EER2 | 48%median 11.0 · 18th ranked | 58%median 11.7 · 11th ranked |
| Heating capacity at 5°F | 49%median 18,200 Btu/h · 17th ranked | 55%median 20,000 Btu/h · 14th ranked |
| Outdoor models | 180 | 239 |
| AHRI certifications | 2,088 | 109,938 |
Share of models meeting each standard
| Standard | Fujitsu | York |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.3%60 models | 54.4%130 models |
| CEE 2026 Tier 1 (Split ASHP) | 32.2%58 models | 54.4%130 models |
| CEE Advanced Tier (Split ASHP) | 7.8%14 models | 7.5%18 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 30%54 models | 41.4%99 models |
| DOE Cold Climate Heat Pump Challenge | 7.8%14 models | 7.5%18 models |
| ENERGY STAR Cold Climate | 28.9%52 models | 38.1%91 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Fujitsu
- York
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Fujitsu | York |
|---|---|---|
| Ducted, up to 1.5 tons | 12 · index 58% | 24 · index 56% |
| Ducted, 2 tons | 17 · index 38% | 21 · index 48% |
| Ducted, 2.5 to 3 tons | 44 · index 40% | 58 · index 50% |
| Ducted, 3.5 to 4.5 tons | 57 · index 44% | 70 · index 50% |
| Ducted, 5 tons and up | 22 · index 34% | 13 · index 43% |
| Non-ducted, up to 1.5 tons | 27 · index 76% | 49 · index 61% |
| Non-ducted, 2 tons | 8 · index 76% | 17 · index 63% |
| Non-ducted, 2.5 to 3 tons | 11 · index 69% | 16 · index 52% |
| Non-ducted, 3.5 to 4.5 tons | 9 · index 63% | 6 · index 56% |
| Non-ducted, 5 tons and up | 1 · index 79% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FujitsuCold-climate score, best model | YorkCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.7(50 is the typical model of its size class) (higher)AOUH18KUAH1with ducted air handler ARUH18KUAS7 of 12 models qualify · AHRI 218814795 | 80.8(50 is the typical model of its size class)YPAS18BLFASDQ1with ducted air handler YPPIMB18UFA1DQ11 of 22 models qualify · AHRI 218694255 |
| Ducted, 2 tons | 83.6(50 is the typical model of its size class)AOUH24KUAH1with ducted air handler ARUH24KUAS5 of 17 models qualify · AHRI 218807602 | 90.1(50 is the typical model of its size class) (higher)HH824E2S11with ducted air handler D(A,C,E)36A4K+JMC12B2SN1+TDR12 of 23 models qualify · AHRI 218026253 |
| Ducted, 2.5 to 3 tons | 87.1(50 is the typical model of its size class)AOUH30KUAH1with ducted air handler AMUH30KUAS8 of 44 models qualify · AHRI 217895716 | 92.1(50 is the typical model of its size class) (higher)HH836E2S11with indoor coil D(A,C,E)36A4K+TDR and furnace Z9ET080C16SMPS122 of 60 models qualify · AHRI 218350129 |
| Ducted, 3.5 to 4.5 tons | 80.9(50 is the typical model of its size class)FOP1948MJAYCAwith indoor coil FCCA4821SYEA and furnace FF80TV407517UH10 of 57 models qualify · AHRI 216687202 | 90.1(50 is the typical model of its size class) (higher)HH860E2S11with ducted air handler DM59A4K+JMC20D2SN1+TDR19 of 68 models qualify · AHRI 218026269 |
| Ducted, 5 tons and up | 72.3(50 is the typical model of its size class) (higher)AOUK060MSAN71 of 22 models qualify · AHRI 218467769 | 64.2(50 is the typical model of its size class)PH9E60N00D212 of 13 models qualify · AHRI 218450295 |
| Non-ducted, up to 1.5 tons | 98.5(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS25 of 27 models qualify · AHRI 216018255 | 92.4(50 is the typical model of its size class)YPAS18BLFASDQ1with ductless indoor unit YPCIB18UFA1DQ42 of 49 models qualify · AHRI 218694256 |
| Non-ducted, 2 tons | 86.5(50 is the typical model of its size class)AOUH24KWAH36 of 8 models qualify · AHRI 215447693 | 97.0(50 is the typical model of its size class) (higher)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ14 of 17 models qualify · AHRI 218694257 |
| Non-ducted, 2.5 to 3 tons | 94.5(50 is the typical model of its size class)AOUH30KUAH1with ductless indoor unit AUUH30KUAS9 of 11 models qualify · AHRI 217895708 | 97.3(50 is the typical model of its size class) (higher)YPAS30BLFASDQ1with ductless indoor unit YPCIB30UFA1DQ12 of 16 models qualify · AHRI 218694248 |
| Non-ducted, 3.5 to 4.5 tons | 77.1(50 is the typical model of its size class) (higher)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models qualify · AHRI 217895710 | 59.5(50 is the typical model of its size class)YPAS48BUFASDQ1with ductless indoor unit YPPFCB48UFA1DQ4 of 6 models qualify · AHRI 218696687 |
| Non-ducted, 5 tons and up | 72.0(50 is the typical model of its size class)AOUK060MSAN71 of 1 models qualify · AHRI 218466063 | No models in this size class |
All-around best
| Size and duct type | FujitsuAll-around score, best model | YorkAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 90.1(50 is the typical model of its size class) (higher)AOUH12KUBS1with ducted air handler ADUH12KUBS12 of 12 models have all five ratings · AHRI 218814799 | 80.7(50 is the typical model of its size class)YPAS12BLFASDQ1with ducted air handler YPPIMB12UFA1DQ23 of 23 models have all five ratings · AHRI 218694251 |
| Ducted, 2 tons | 85.9(50 is the typical model of its size class) (higher)AOUH24KWAH317 of 17 models have all five ratings · AHRI 215447694 | 77.5(50 is the typical model of its size class)HH824E2S11with ducted air handler D(A,C,E)36A4K+JME08B2SN1+TDR25 of 25 models have all five ratings · AHRI 218026254 |
| Ducted, 2.5 to 3 tons | 86.3(50 is the typical model of its size class)AOUH30KUAH1with ducted air handler AMUH30KUAS31 of 44 models have all five ratings · AHRI 217895716 | 91.3(50 is the typical model of its size class) (higher)YPAS30BUFASDQ1with ducted air handler YPPIMB30UFA1DQ39 of 55 models have all five ratings · AHRI 218694240 |
| Ducted, 3.5 to 4.5 tons | 85.6(50 is the typical model of its size class)AOUH42KUAH1with ducted air handler ARUH42KUAS32 of 53 models have all five ratings · AHRI 217895714 | 86.0(50 is the typical model of its size class) (higher)HH860E2S11with ducted air handler D(A,C,E)60B3K+JMC20D2SN1+TDR45 of 69 models have all five ratings · AHRI 218014963 |
| Ducted, 5 tons and up | 57.0(50 is the typical model of its size class)WP15AY60AJ2Nwith ducted air handler FHRNTT6024S*YTNAAlso listed as FOP1560TJAYNA16 of 26 models have all five ratings · AHRI 215415496 | 70.5(50 is the typical model of its size class) (higher)PH9E60N00D216 of 14 models have all five ratings · AHRI 218450295 |
| Non-ducted, up to 1.5 tons | 99.1(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS27 of 27 models have all five ratings · AHRI 216018255 | 90.1(50 is the typical model of its size class)YRACXJ12WHAAwith ductless indoor unit YRAKXJ12PHAA49 of 49 models have all five ratings · AHRI 218037193 |
| Non-ducted, 2 tons | 88.5(50 is the typical model of its size class) (higher)AOUH24KWAH37 of 8 models have all five ratings · AHRI 215447693 | 85.7(50 is the typical model of its size class)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ17 of 17 models have all five ratings · AHRI 218694257 |
| Non-ducted, 2.5 to 3 tons | 90.1(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS10 of 11 models have all five ratings · AHRI 217895708 | 85.2(50 is the typical model of its size class)YPAS30BUFASDQ1with ductless indoor unit YPCIB30UFA1DQ16 of 16 models have all five ratings · AHRI 218694244 |
| Non-ducted, 3.5 to 4.5 tons | 80.2(50 is the typical model of its size class) (higher)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models have all five ratings · AHRI 217895710 | 67.8(50 is the typical model of its size class)YRAMX42N5HBA6 of 6 models have all five ratings · AHRI 218080472 |
| Non-ducted, 5 tons and up | 78.9(50 is the typical model of its size class)AOUK060MSAN71 of 1 models have all five ratings · AHRI 218466063 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Fujitsu | York |
|---|---|---|
| COP at 5°F | beats 100% · 2.62AOUH12KTAP1Non-ducted, up to 1.5 tons | beats 100% · 3.55UPC24CN23STG1Ducted, 2 tons |
| Capacity retention at 5°F | beats 100% · 102%AOUH42KUAH1Non-ducted, 3.5 to 4.5 tons | beats 100% · 147%YRACXJ09WHAANon-ducted, up to 1.5 tons |
| HSPF2 | beats 98% · 14.0AOUH09KTAP1Non-ducted, up to 1.5 tons | beats 100% · 12.0YPAS30BUFASDQ1Non-ducted, 2.5 to 3 tons |
| SEER2 | beats 100% · 33.5AOUH09KTAP1Non-ducted, up to 1.5 tons | beats 100% · 22.0YH960E2C11Also sold as Coleman XH960E2C11Ducted, 3.5 to 4.5 tons |
| EER2 | beats 100% · 19.1AOUH09KTAP1Non-ducted, up to 1.5 tons | beats 99% · 14.4YPAS36BLFASDQ1Non-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 100% · 25,400 Btu/hAOUH18KZAH1Non-ducted, up to 1.5 tons | beats 100% · 23,000 Btu/hYRACXJ18WHAAAlso listed as YRACXJ18WHBANon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Fujitsu (median, middle 50%)
- York (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Fujitsu, 47°F | 59 | 100% | 100% | 100% | 100% | 100% |
| Fujitsu, 17°F | 59 | 65% | 71% | 82% | 90% | 95% |
| Fujitsu, 5°F | 59 | 59% | 66% | 73% | 86% | 94% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Fujitsu, 47°F | 59 | 2.5 | 2.75 | 3.21 | 3.56 | 4.12 |
| Fujitsu, 17°F | 59 | 2.28 | 2.32 | 2.4 | 2.6 | 2.72 |
| Fujitsu, 5°F | 59 | 2 | 2.1 | 2.18 | 2.3 | 2.41 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| York, 47°F | 50 | 100% | 100% | 100% | 100% | 100% |
| York, 17°F | 50 | 66% | 73% | 79% | 88% | 97% |
| York, 5°F | 50 | 58% | 62% | 72% | 80% | 84% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| York, 47°F | 50 | 2.7 | 2.96 | 3.23 | 3.4 | 3.62 |
| York, 17°F | 50 | 2.15 | 2.2 | 2.3 | 2.4 | 2.51 |
| York, 5°F | 50 | 1.8 | 1.88 | 2 | 2.1 | 2.2 |
Source: NEEP ccASHP list · as of