Against heat pumps of the same size and type, a typical GOETTL model beats 42% and a typical MRCOOL model 55%. MRCOOL rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

GOETTL

42%

of similar heat pumps beaten by its typical model

Below average

110 models listed

MRCOOL

55%

of similar heat pumps beaten by its typical model

About average

111 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FGOETTL: Beats 39%MRCOOL: Beats 50%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FGOETTL: Beats 19%MRCOOL: Beats 42%
  • Winter-long heating efficiencyHSPF2GOETTL: Beats 26%MRCOOL: Beats 51%
  • Summer-long cooling efficiencySEER2GOETTL: Beats 37%MRCOOL: Beats 50%
  • Hot-day cooling efficiencyEER2GOETTL: Beats 63%MRCOOL: Beats 56%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    GOETTL
    14%
    MRCOOL
    47%
  • Xcel CC

    GOETTL
    3%
    MRCOOL
    25%
  • CEE Advanced

    GOETTL
    0%
    MRCOOL
    0%
  • ENERGY STAR CC

    GOETTL
    0%
    MRCOOL
    23%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

GOETTL

  1. 1ASZV903610A*with ducted air handler AMVE48DP1400AGOETTLAlso listed as GSZV903610A3 tons · 33,600 Btu/h · DuctedCold-climate pick, score 47.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    73% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.2 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    66.7score / 100Heating 47 · Cooling 86
  2. 2ASZC703610A*with ducted air handler CAPTA4230*4A*+MBVC2001**-1AGOETTLAlso listed as GSZC703610A3 tons · 34,800 Btu/h · DuctedNot a cold-climate pick: keeps 50% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    50% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    8.2 (HSPF2)
    Good
    Cooling efficiency
    17.2 (SEER2)
    Good
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    64.3score / 100Heating 45 · Cooling 84
  3. 3ASZH503610A*with ducted air handler CAPTA4230*4A*+MBVC1601**-1AGOETTLAlso listed as GSZH503610A3 tons · 34,200 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    52% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    58.5score / 100Heating 41 · Cooling 76

MRCOOL

  1. 1MULTI3-27HP230BMRCOOL2.5 tons · 28,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    75.4score / 100Heating 65 · Cooling 86
  2. 2MHP17L36P-**Awith indoor coil MCDP0048CNPB+TDR and furnace MGD80SE110C5AMRCOOL3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    53% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.34 (COP at 5°F)
    Great
    Winter efficiency
    8.7 (HSPF2)
    Good
    Cooling efficiency
    16.6 (SEER2)
    Good
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    70.1score / 100Heating 58 · Cooling 83
  3. 3MHP17L30P-**Awith indoor coil MCDP0042BNPB+TDR and furnace MGD80SE090B4AMRCOOL2.5 tons · 29,800 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets CEE 2025
    Heat kept at 5°F
    49% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.34 (COP at 5°F)
    Great
    Winter efficiency
    8.6 (HSPF2)
    Good
    Cooling efficiency
    16.2 (SEER2)
    Good
    Hot-day cooling
    13.5 (EER2)
    Top 10%
    68.0score / 100Heating 55 · Cooling 81

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter