Skip to content

HAIER vs Viessmann heat pumps

Measured against models of the same size and duct type, Viessmann scores higher on 5 of the 6 ratings. HAIER has 53 outdoor models, Viessmann has 53 outdoor models. HAIER and Viessmann have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
HAIER and Viessmann on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Viessmann scores higher on 5 of the 6 ratings.
  • HAIER
  • Viessmann
  • Other ranked manufacturers
HAIERViessmann

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHAIERViessmann
Efficiency index45%median —54%median —
COP at 5°F34%median 1.8053%median 1.95
Capacity retention at 5°F48%median 72%51%median 67%
HSPF257%median 9.563%median 9.2
SEER247%median 20.058%median 18.7
EER240%median 12.046%median 10.7
Heating capacity at 5°F51%median 15,454 Btu/h51%median 18,000 Btu/h
Outdoor models5353
AHRI certifications112123

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHAIERViessmann
CEE 2025 Tier 1 (Split ASHP)49.1%26 models64.2%34 models
CEE 2026 Tier 1 (Split ASHP)49.1%26 models60.4%32 models
CEE Advanced Tier (Split ASHP)7.5%4 models3.8%2 models
Xcel Energy Colorado cold-climate ASHP (2025)41.5%22 models43.4%23 models
DOE Cold Climate Heat Pump Challenge7.5%4 models3.8%2 models
ENERGY STAR Cold Climate30.2%16 models47.2%25 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • HAIER
  • Viessmann
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHAIERViessmann
Ducted, up to 1.5 tons6 · index 36%6 · index 62%
Ducted, 2 tons6 · index 42%4 · index 65%
Ducted, 2.5 to 3 tons7 · index 38%9 · index 54%
Ducted, 3.5 to 4.5 tons6 · index 34%6 · index 59%
Ducted, 5 tons and upNone2 · index 50%
Non-ducted, up to 1.5 tons27 · index 57%20 · index 54%
Non-ducted, 2 tons10 · index 48%4 · index 48%
Non-ducted, 2.5 to 3 tons7 · index 34%11 · index 49%
Non-ducted, 3.5 to 4.5 tons5 · index 15%5 · index 46%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHAIERCold-climate score, best modelViessmannCold-climate score, best model
Ducted, up to 1.5 tons53.8(50 is the typical model of its size class)2U20EH2HD**4 of 6 models qualify · AHRI 21015102681.6(50 is the typical model of its size class) (higher)DLCSRBH18AAKwith ducted air handler DLFSDAH18XHK5 of 6 models qualify · AHRI 215569862
Ducted, 2 tons57.6(50 is the typical model of its size class)3U24EH2HD**2 of 6 models qualify · AHRI 21008219979.6(50 is the typical model of its size class) (higher)DLCSRBH24AAKwith ducted air handler DLFSDAH24XAK4 of 4 models qualify · AHRI 215569794
Ducted, 2.5 to 3 tons61.9(50 is the typical model of its size class)4U36EH2HD**2 of 7 models qualify · AHRI 21015102778.7(50 is the typical model of its size class) (higher)DLCURAH36ABKwith ducted air handler DLFULAH36XCX + CI3 of 9 models qualify · AHRI 215569769
Ducted, 3.5 to 4.5 tons53.6(50 is the typical model of its size class)1U4248LP2HD**with ducted air handler USYM42UCDD1 of 6 models qualify · AHRI 21172910575.1(50 is the typical model of its size class) (higher)DLCMHBH48EAK4 of 6 models qualify · AHRI 215569823
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons96.0(50 is the typical model of its size class) (higher)1U12EH2HE**with ductless indoor unit AW12EH2HE14 of 27 models qualify · AHRI 21240944889.8(50 is the typical model of its size class)DLCSRBH06AAKwith ductless indoor unit DLFSHCH06XAK10 of 20 models qualify · AHRI 215569846
Non-ducted, 2 tons63.3(50 is the typical model of its size class)3U24EH2HD**4 of 10 models qualify · AHRI 21008219887.1(50 is the typical model of its size class) (higher)DLCSRBH24AAKwith ductless indoor unit DLFSCBH24XAK2 of 4 models qualify · AHRI 215569833
Non-ducted, 2.5 to 3 tons68.2(50 is the typical model of its size class)4U36EH2HD**3 of 7 models qualify · AHRI 21008220174.4(50 is the typical model of its size class) (higher)DLCMHBH36DAK2 of 11 models qualify · AHRI 215569824
Non-ducted, 3.5 to 4.5 tons19.1(50 is the typical model of its size class)1U4248LP2HD**with ductless indoor unit USYL42UCDD1 of 5 models qualify · AHRI 21174460580.7(50 is the typical model of its size class) (higher)DLCMHBH48EAK3 of 5 models qualify · AHRI 215569822

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHAIERAll-around score, best modelViessmannAll-around score, best model
Ducted, up to 1.5 tons45.0(50 is the typical model of its size class)1U09EH2HE**with ducted air handler USYM09UCDSA5 of 6 models have all five ratings · AHRI 21240947285.4(50 is the typical model of its size class) (higher)DLCSRBH09AAKwith ducted air handler DLFSDAH09XAK6 of 6 models have all five ratings · AHRI 215569786
Ducted, 2 tons54.0(50 is the typical model of its size class)3U24EH2HD**3 of 6 models have all five ratings · AHRI 21008219980.2(50 is the typical model of its size class) (higher)DLCSRBH24AAKwith ducted air handler DLFSDAH24XAK4 of 4 models have all five ratings · AHRI 215569794
Ducted, 2.5 to 3 tons44.4(50 is the typical model of its size class)4U36EH2HD**4 of 7 models have all five ratings · AHRI 21015102772.1(50 is the typical model of its size class) (higher)DLCMHBH30DAK9 of 9 models have all five ratings · AHRI 215569818
Ducted, 3.5 to 4.5 tons38.5(50 is the typical model of its size class)1U4248LP2HD**with ducted air handler USYM42UCDD4 of 6 models have all five ratings · AHRI 21172910582.1(50 is the typical model of its size class) (higher)DLCMHBH48EAK6 of 6 models have all five ratings · AHRI 215569823
Ducted, 5 tons and upNo models in this size class57.2(50 is the typical model of its size class)DLCLRCH58AAKwith ducted air handler DLFLDAH58XAK2 of 2 models have all five ratings · AHRI 215569836
Non-ducted, up to 1.5 tons95.4(50 is the typical model of its size class) (higher)1U09EH2VHE*with ductless indoor unit AW09EH2VHD21 of 27 models have all five ratings · AHRI 20644581992.3(50 is the typical model of its size class)DLCSRBH06AAKwith ductless indoor unit DLFSHCH06XAK19 of 20 models have all five ratings · AHRI 215569846
Non-ducted, 2 tons60.7(50 is the typical model of its size class)3U24MS2HD**7 of 10 models have all five ratings · AHRI 20769899884.9(50 is the typical model of its size class) (higher)DLCSRBH24AAKwith ductless indoor unit DLFSHCH24XAK4 of 4 models have all five ratings · AHRI 215569840
Non-ducted, 2.5 to 3 tons49.7(50 is the typical model of its size class)4U36EH2HD**5 of 7 models have all five ratings · AHRI 21008220171.5(50 is the typical model of its size class) (higher)DLCMHBH36DAK11 of 11 models have all five ratings · AHRI 215569824
Non-ducted, 3.5 to 4.5 tons18.2(50 is the typical model of its size class)5U42MS2HD**4 of 5 models have all five ratings · AHRI 21040402773.9(50 is the typical model of its size class) (higher)DLCMHBH48EAK5 of 5 models have all five ratings · AHRI 215569822

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHAIERViessmann
COP at 5°Fbeats 94% · 2.341U18EH2HE**Non-ducted, up to 1.5 tonsbeats 92% · 2.21DLCSRBH24AAKNon-ducted, 2 tons
Capacity retention at 5°Fbeats 97% · 120%1U09EH2VHE*Non-ducted, up to 1.5 tonsbeats 96% · 114%DLCPRBH09AAKNon-ducted, up to 1.5 tons
HSPF2beats 99% · 14.01U09EH2VHE*Non-ducted, up to 1.5 tonsbeats 100% · 15.0DLCPRBH09AAKNon-ducted, up to 1.5 tons
SEER2beats 100% · 30.01U09EH2VHE*Non-ducted, up to 1.5 tonsbeats 99% · 20.9DLCMHBH48EAKDucted, 3.5 to 4.5 tons
EER2beats 97% · 16.01U09EH2VHE*Non-ducted, up to 1.5 tonsbeats 98% · 16.2DLCSRBH09AAKNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/h1U18EH2HE**Non-ducted, up to 1.5 tonsbeats 95% · 48,500 Btu/hDLCURAH60ABKDucted, 3.5 to 4.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
HAIER vs Viessmann: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,707 models (37.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • HAIER (median, middle 50%)
  • Viessmann (median, middle 50%)
Heating capacity, % of its 47°F maximum73%63%COP at maximum capacity1.801.99

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,707100%100%100%100%100%
All rated models, 17°F3,70765%68%76%83%92%
All rated models, 5°F3,70755%58%67%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7072.642.873.13.323.53
All rated models, 17°F3,7071.982.052.22.342.49
All rated models, 5°F3,7071.81.831.922.032.21
HAIER: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
HAIER, 47°F18100%100%100%100%100%
HAIER, 17°F1864%65%69%80%83%
HAIER, 5°F1856%66%73%80%85%
HAIER: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
HAIER, 47°F182.893.013.353.64.21
HAIER, 17°F182.142.32.492.52.62
HAIER, 5°F181.81.81.81.942.09
Viessmann: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Viessmann, 47°F36100%100%100%100%100%
Viessmann, 17°F3663%67%73%76%80%
Viessmann, 5°F3655%57%63%70%78%
Viessmann: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Viessmann, 47°F362.682.823.063.313.52
Viessmann, 17°F361.892.032.172.312.51
Viessmann, 5°F361.821.91.992.072.19

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter