Skip to content

HAIER vs Viessmann heat pumps

Measured against models of the same size and duct type, Viessmann scores higher on 6 of the 6 ratings. HAIER has 38 outdoor models, Viessmann has 43 outdoor models. HAIER and Viessmann have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
HAIER and Viessmann on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Viessmann scores higher on 6 of the 6 ratings.
  • HAIER
  • Viessmann
  • Other ranked manufacturers
HAIERViessmann

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHAIERViessmann
Efficiency index51%median —60%median —
COP at 5°F32%median 1.8053%median 2.00
Capacity retention at 5°F62%median 80%73%median 88%
HSPF268%median 9.574%median 9.5
SEER253%median 20.059%median 17.0
EER242%median 12.050%median 11.0
Heating capacity at 5°F64%median 19,950 Btu/h74%median 25,000 Btu/h
Outdoor models3843
AHRI certifications2,395170

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHAIERViessmann
CEE 2025 Tier 1 (Split ASHP)94.7%36 models83.7%36 models
CEE 2026 Tier 1 (Split ASHP)84.2%32 models83.7%36 models
CEE Advanced Tier (Split ASHP)0%0 models4.7%2 models
Xcel Energy Colorado cold-climate ASHP (2025)81.6%31 models79.1%34 models
DOE Cold Climate Heat Pump Challenge0%0 models4.7%2 models
ENERGY STAR Cold Climate71.1%27 models69.8%30 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • HAIER
  • Viessmann
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,327 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00599 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHAIERViessmann
Ducted, up to 1.5 tons9 · index 52%8 · index 68%
Ducted, 2 tons6 · index 45%7 · index 59%
Ducted, 2.5 to 3 tons8 · index 52%16 · index 55%
Ducted, 3.5 to 4.5 tons7 · index 54%11 · index 57%
Ducted, 5 tons and up1 · index 75%None
Non-ducted, up to 1.5 tons14 · index 49%5 · index 78%
Non-ducted, 2 tons5 · index 51%2 · index 80%
Non-ducted, 2.5 to 3 tons5 · index 45%6 · index 58%
Non-ducted, 3.5 to 4.5 tons2 · index 50%4 · index 52%
Non-ducted, 5 tons and up1 · index 68%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHAIERCold-climate score, best modelViessmannCold-climate score, best model
Ducted, up to 1.5 tons68.2(50 is the typical model of its size class)2Q20RT2BE**9 of 9 models qualify · AHRI 21702196586.9(50 is the typical model of its size class) (higher)D5CUHAH18AAKwith ducted air handler D5MUWAQ18XA37 of 8 models qualify · AHRI 218668521
Ducted, 2 tons74.5(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler PE(S,T)35J5 of 6 models qualify · AHRI 21885729185.8(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK7 of 7 models qualify · AHRI 217178805
Ducted, 2.5 to 3 tons79.1(50 is the typical model of its size class)AU36VFPTYA6 of 8 models qualify · AHRI 21839414183.6(50 is the typical model of its size class) (higher)D5CMHAH36EAK11 of 16 models qualify · AHRI 217178827
Ducted, 3.5 to 4.5 tons80.4(50 is the typical model of its size class)AU48VFPTYA5 of 7 models qualify · AHRI 21839414282.6(50 is the typical model of its size class) (higher)D5CMHAH48FAK10 of 11 models qualify · AHRI 217178830
Ducted, 5 tons and up81.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394143No models in this size class
Non-ducted, up to 1.5 tons67.4(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models qualify · AHRI 21807301897.0(50 is the typical model of its size class) (higher)D5CSHAH06AAKwith ductless indoor unit D5FSHAH06XAK5 of 5 models qualify · AHRI 217178781
Non-ducted, 2 tons62.9(50 is the typical model of its size class)3Q24RT2BE**4 of 5 models qualify · AHRI 21700975790.1(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ductless indoor unit D5FSCAH24XAK2 of 2 models qualify · AHRI 217178803
Non-ducted, 2.5 to 3 tons74.4(50 is the typical model of its size class)AU36VFPTYA4 of 5 models qualify · AHRI 21839413889.4(50 is the typical model of its size class) (higher)D5CLHAH36AAKwith ductless indoor unit D5FCFAH36XAK4 of 6 models qualify · AHRI 217178810
Non-ducted, 3.5 to 4.5 tons67.6(50 is the typical model of its size class)AU48VFPTYA2 of 2 models qualify · AHRI 21839413975.7(50 is the typical model of its size class) (higher)D5CMHAH48FAK4 of 4 models qualify · AHRI 217178831
Non-ducted, 5 tons and up64.2(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394140No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHAIERAll-around score, best modelViessmannAll-around score, best model
Ducted, up to 1.5 tons66.5(50 is the typical model of its size class)1Q09RT2BE**with ducted air handler US09MB2BE9 of 9 models have all five ratings · AHRI 21703649187.6(50 is the typical model of its size class) (higher)D5CSHAH09AAKwith ducted air handler D5FSDAH12XAK8 of 8 models have all five ratings · AHRI 217178787
Ducted, 2 tons67.3(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler NAM30E3TA56 of 6 models have all five ratings · AHRI 21727022280.3(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK7 of 7 models have all five ratings · AHRI 217178805
Ducted, 2.5 to 3 tons75.0(50 is the typical model of its size class)AU36VFPTYA8 of 8 models have all five ratings · AHRI 21839414185.6(50 is the typical model of its size class) (higher)D5CMHAH30EAK16 of 16 models have all five ratings · AHRI 217178824
Ducted, 3.5 to 4.5 tons70.2(50 is the typical model of its size class)AU48VFPTYA7 of 7 models have all five ratings · AHRI 21839414285.0(50 is the typical model of its size class) (higher)D5CMHAH48FAK11 of 11 models have all five ratings · AHRI 217178830
Ducted, 5 tons and up74.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394143No models in this size class
Non-ducted, up to 1.5 tons78.7(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models have all five ratings · AHRI 21807301896.9(50 is the typical model of its size class) (higher)D5CSHAH06AAKwith ductless indoor unit D5FSHAH06XAK5 of 5 models have all five ratings · AHRI 217178781
Non-ducted, 2 tons68.8(50 is the typical model of its size class)3Q24RT2BE**5 of 5 models have all five ratings · AHRI 21700975780.5(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ductless indoor unit D5FSHAH24XAK2 of 2 models have all five ratings · AHRI 217178802
Non-ducted, 2.5 to 3 tons76.7(50 is the typical model of its size class)AU36VFPTYA5 of 5 models have all five ratings · AHRI 21839413885.8(50 is the typical model of its size class) (higher)D5CMHAH30EAK6 of 6 models have all five ratings · AHRI 217178823
Non-ducted, 3.5 to 4.5 tons73.9(50 is the typical model of its size class)AU48VFPTYA2 of 2 models have all five ratings · AHRI 21839413976.6(50 is the typical model of its size class) (higher)D5CMHAH48FAK4 of 4 models have all five ratings · AHRI 217178829
Non-ducted, 5 tons and up68.0(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394140No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHAIERViessmann
COP at 5°Fbeats 93% · 2.491U36T3PC*HEDucted, 2.5 to 3 tonsbeats 97% · 2.40D5CSHAH06AAKNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 82%AU60VFPTYADucted, 5 tons and upbeats 100% · 116%D5CMHAH30EAKNon-ducted, 2.5 to 3 tons
HSPF2beats 100% · 13.5AU36VFPTYADucted, 2.5 to 3 tonsbeats 99% · 14.8D5CSHAH06AAKNon-ducted, up to 1.5 tons
SEER2beats 95% · 27.01Q09RT2BE**Non-ducted, up to 1.5 tonsbeats 99% · 20.5D5CMHAH48FAKDucted, 3.5 to 4.5 tons
EER2beats 99% · 14.4AU36VFPTYANon-ducted, 2.5 to 3 tonsbeats 99% · 18.0D5CSHAH06AAKNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 20,000 Btu/h2Q20RT2BE**Ducted, up to 1.5 tonsbeats 98% · 19,600 Btu/hD5CUHAH18AAKDucted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
HAIER vs Viessmann: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,310 models (46.4% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • HAIER (median, middle 50%)
  • Viessmann (median, middle 50%)
Heating capacity, % of its 47°F maximum73%76%COP at maximum capacity1.802.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,310100%100%100%100%100%
All rated models, 17°F6,31064%69%74%83%91%
All rated models, 5°F6,31057%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3102.833.243.483.66
All rated models, 17°F6,31022.132.292.422.61
All rated models, 5°F6,3101.81.8722.12.24
HAIER: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
HAIER, 47°F35100%100%100%100%100%
HAIER, 17°F3559%60%64%76%80%
HAIER, 5°F3563%70%73%81%91%
HAIER: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
HAIER, 47°F353.083.23.53.653.76
HAIER, 17°F352.212.42.52.62.8
HAIER, 5°F351.81.81.81.832.06
Viessmann: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Viessmann, 47°F39100%100%100%100%100%
Viessmann, 17°F3969%78%79%86%90%
Viessmann, 5°F3959%70%76%82%83%
Viessmann: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Viessmann, 47°F392.983.13.243.453.58
Viessmann, 17°F392.022.162.292.422.61
Viessmann, 5°F391.841.9222.12.15

Source: NEEP ccASHP list · as of