Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
HAXXAIR vs HITACHI: heat pump ratings compared
Against heat pumps of the same size and type, a typical HAXXAIR model beats 57% and a typical HITACHI model 58%. HITACHI rates slightly higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
HAXXAIR
57%
of similar heat pumps beaten by its typical model
Above average26 models listed
HITACHI
58%
of similar heat pumps beaten by its typical model
Above average27 models listed
- Efficiency on a 5°F dayCOP at 5°FHAXXAIR: Beats 58%HITACHI: Beats 72%
- Heating power kept at 5°FCapacity at 5°F vs 47°FHAXXAIR: Beats 68%HITACHI: Beats 57%
- Winter-long heating efficiencyHSPF2HAXXAIR: Beats 46%HITACHI: Beats 65%
- Summer-long cooling efficiencySEER2HAXXAIR: Beats 49%HITACHI: Beats 50%
- Hot-day cooling efficiencyEER2HAXXAIR: Beats 44%HITACHI: Beats 53%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- HAXXAIR
- 65%
- HITACHI
- 74%
Xcel CC
- HAXXAIR
- 65%
- HITACHI
- 67%
CEE Advanced
- HAXXAIR
- 0%
- HITACHI
- 0%
ENERGY STAR CC
- HAXXAIR
- 58%
- HITACHI
- 15%
Top cold-climate picks, ducted up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
HAXXAIR
- 1HVHSC-18T2Dwith ducted air handler HAHS-18T2DHAXXAIR1.5 tons · 18,000 Btu/h · DuctedKeeps 72% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.01 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
- 2HVHSC-12T2Dwith ducted air handler HAHS-12T2DHAXXAIR1 ton · 12,000 Btu/h · DuctedKeeps 74% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.01 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.0 (HSPF2)
- Below the middle
- 3HVHM-18T2DHAXXAIR1.5 tons · 18,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.4 (HSPF2)
- Good
HITACHI
- 1RAS-1.0PNNBDH1with ducted air handler RPIL-1.0PNN1DHHITACHI1 ton · 9,000 Btu/h · DuctedKeeps 79% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 79% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.0 (HSPF2)
- Below the middle
- 2RAS-2.0PNNBDH1with ducted air handler RPIL-2.0PNN1DHHITACHI1.5 tons · 18,000 Btu/h · DuctedKeeps 72% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view