Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Hisense vs York heat pumps
Measured against models of the same size and duct type, Hisense and York split the 6 ratings 3–3. Hisense has 159 outdoor models, York has 179 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Hisense
- York
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Hisense | York |
|---|---|---|
| Efficiency index | 57% (higher)median — · 10th ranked | 51% (higher)median — · 21st ranked |
| COP at 5°F | 40%median 1.80 · 26th ranked | 69%median 2.20 · 5th ranked |
| Capacity retention at 5°F | 55% (higher)median 72% · 16th ranked | 50% (higher)median 69% · 18th ranked |
| HSPF2 | 42% (higher)median 9.0 · 20th ranked | 37% (higher)median 7.7 · 23rd ranked |
| SEER2 | 50% (higher)median 20.5 · 15th ranked | 38% (higher)median 15.2 · 24th ranked |
| EER2 | 56%median 12.5 · 13th ranked | 57%median 11.0 · 9th ranked |
| Heating capacity at 5°F | 45%median 9,600 Btu/h · 20th ranked | 49%median 24,200 Btu/h · 17th ranked |
| Outdoor models | 159 | 179 |
| AHRI certifications | 369 | 65,299 |
Share of models meeting each standard
| Standard | Hisense | York |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 64.8%103 models | 26.3%47 models |
| CEE 2026 Tier 1 (Split ASHP) | 64.8%103 models | 26.3%47 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0.6%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 59.1%94 models | 25.7%46 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0.6%1 models |
| ENERGY STAR Cold Climate | 47.2%75 models | 2.2%4 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Hisense
- York
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Hisense | York |
|---|---|---|
| Ducted, up to 1.5 tons | 5 · index 46% | 8 · index 42% |
| Ducted, 2 tons | 3 · index 57% | 17 · index 47% |
| Ducted, 2.5–3 tons | 5 · index 65% | 53 · index 51% |
| Ducted, 3.5–4.5 tons | 6 · index 58% | 71 · index 60% |
| Ducted, 5 tons and up | None | 19 · index 50% |
| Non-ducted, up to 1.5 tons | 114 · index 59% | 9 · index 25% |
| Non-ducted, 2 tons | 24 · index 53% | 2 · index 41% |
| Non-ducted, 2.5–3 tons | 10 · index 63% | 6 · index 54% |
| Non-ducted, 3.5–4.5 tons | 1 · index 45% | 5 · index 46% |
| Non-ducted, 5 tons and up | None | 2 · index 46% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | HisenseCold-climate score, best model | YorkCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.9(50 is the typical model of its size class)AUW-09U3SSwith ducted air handler ADT-09UX3SBL4 of 4 models qualify · AHRI 204835479 | 59.7(50 is the typical model of its size class) (higher)THF2B18S21with ducted air handler AE(D,N,U)+CM24D24+TDR7 of 8 models qualify · AHRI 214606310 |
| Ducted, 2 tons | 65.6(50 is the typical model of its size class) (higher)AUWR-24U3SF2with ducted air handler A(E,F)M304+TDR4 of 4 models qualify · AHRI 214447344 | 60.6(50 is the typical model of its size class)THE2B24T21with ducted air handler AX242BTA10 of 16 models qualify · AHRI 211634285 |
| Ducted, 2.5–3 tons | 78.9(50 is the typical model of its size class)AUWR-36U3SAwith ducted air handler HE35936+TD5 of 5 models qualify · AHRI 215333846 | 83.8(50 is the typical model of its size class) (higher)HMH72B341with indoor coil CM36B36+TDR and furnace TM9V120D20MP1222 of 53 models qualify · AHRI 211628039 |
| Ducted, 3.5–4.5 tons | 74.5(50 is the typical model of its size class)AUWR-60U3SP2with ducted air handler L(E,G)M60I44 of 6 models qualify · AHRI 213896272 | 77.7(50 is the typical model of its size class) (higher)RHP15048B21with ducted air handler L(E,G)M60A4Also sold as Champion Heating and Cooling THF2B48T2124 of 72 models qualify · AHRI 213612208 |
| Ducted, 5 tons and up | No models in this size class | 70.2(50 is the typical model of its size class)YMKE60BNJMFMO-X1 of 19 models qualify · AHRI 205739196 |
| Non-ducted, up to 1.5 tons | 78.4(50 is the typical model of its size class) (higher)AUW-09U3SSwith ductless indoor unit ACT-09UR3SCA72 of 114 models qualify · AHRI 204835478 | 64.2(50 is the typical model of its size class)DHS18CMB22S5 of 9 models qualify · AHRI 207616532 |
| Non-ducted, 2 tons | 72.0(50 is the typical model of its size class) (higher)AUW-24U3SAwith ductless indoor unit ACT-24UR3SGB14 of 24 models qualify · AHRI 203167189 | 66.1(50 is the typical model of its size class)DHS24CMB22S1 of 2 models qualify · AHRI 207616534 |
| Non-ducted, 2.5–3 tons | 77.2(50 is the typical model of its size class) (higher)AUW-36U3ST1with ductless indoor unit AUC-36UR3SHB12 of 10 models qualify · AHRI 205141567 | 60.8(50 is the typical model of its size class)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models qualify · AHRI 203994967 |
| Non-ducted, 3.5–4.5 tons | 41.9(50 is the typical model of its size class) (higher)AMW5-42U3STA1 of 1 models qualify · AHRI 205123813 | 31.6(50 is the typical model of its size class)DHS42CMB22S1 of 5 models qualify · AHRI 207616540 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | HisenseAll-around score, best model | YorkAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 57.7(50 is the typical model of its size class) (higher)AUW-09U3SSwith ducted air handler ADT-09UX3SBL4 of 4 models have all five ratings · AHRI 204835479 | 57.1(50 is the typical model of its size class)YH2F18SB21with ducted air handler AE*S+CM24C24+TDR7 of 7 models have all five ratings · AHRI 216437405 |
| Ducted, 2 tons | 71.6(50 is the typical model of its size class)AMW3-24U3SAA4 of 4 models have all five ratings · AHRI 203446790 | 77.1(50 is the typical model of its size class) (higher)YMSJYH024BAAND-1with ducted air handler YMSJXH024BAAN--517 of 17 models have all five ratings · AHRI 217734524 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class) (higher)AMW4-36U3STA5 of 5 models have all five ratings · AHRI 203459336 | 76.1(50 is the typical model of its size class)YMSJYH048BAAND-1with ducted air handler YMSJXH048BAAN--534 of 51 models have all five ratings · AHRI 217734526 |
| Ducted, 3.5–4.5 tons | 65.5(50 is the typical model of its size class)AUWR-48U3SPwith ducted air handler DC61A44-245R6 of 6 models have all five ratings · AHRI 213411088 | 83.7(50 is the typical model of its size class) (higher)YZV48B21with indoor coil XAMC48HE3N1+CC and furnace TM9V100C16MP1248 of 73 models have all five ratings · AHRI 211207031 |
| Ducted, 5 tons and up | No models in this size class | 75.1(50 is the typical model of its size class)YMKE60BNJMFMO-X12 of 20 models have all five ratings · AHRI 205739196 |
| Non-ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class) (higher)AS-09UW3SXE00with ductless indoor unit AS-09UW3SXE**0082 of 114 models have all five ratings · AHRI 201981253 | 50.6(50 is the typical model of its size class)DHS18CMB22S9 of 9 models have all five ratings · AHRI 207616532 |
| Non-ducted, 2 tons | 67.5(50 is the typical model of its size class) (higher)AMW3-24U3SAAwith ductless indoor unit AST-07UW3SVE**00+AST-09UW3SVE**00+AST-09UW3SVE**0014 of 24 models have all five ratings · AHRI 202864314 | 55.4(50 is the typical model of its size class)DHS24CMB22S2 of 2 models have all five ratings · AHRI 207616534 |
| Non-ducted, 2.5–3 tons | 69.5(50 is the typical model of its size class)AMW4-36U3STAwith ductless indoor unit AST-09UW3SVE**00+AST-09UW3SVE**00+AST-09UW3SVE**00+AST-09UW3SVE**002 of 10 models have all five ratings · AHRI 202911535 | 74.6(50 is the typical model of its size class) (higher)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models have all five ratings · AHRI 203994967 |
| Non-ducted, 3.5–4.5 tons | 44.5(50 is the typical model of its size class)AMW5-42U3STA1 of 1 models have all five ratings · AHRI 205123812 | 67.0(50 is the typical model of its size class) (higher)YVAHP048B21S*Also sold as Coleman CVAHP048B21S3 of 5 models have all five ratings · AHRI 203994968 |
| Non-ducted, 5 tons and up | No models in this size class | 68.5(50 is the typical model of its size class)YVAHP060B21S*2 of 2 models have all five ratings · AHRI 203994964 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Hisense | York |
|---|---|---|
| COP at 5°F | beats 97% · 2.80AUWR-24U3SF2Ducted, up to 1.5 tons | beats 100% · 3.44THE2B42T21Ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 99% · 113%AMW4-36U3STANon-ducted, 2.5–3 tons | beats 100% · 149%THE2B18S21Ducted, up to 1.5 tons |
| HSPF2 | beats 83% · 9.5AUW-36U3ST1Ducted, 2.5–3 tons | beats 98% · 10.0YVAHP048B21S*Also sold as Coleman CVAHP048B21SDucted, 3.5–4.5 tons |
| SEER2 | beats 96% · 27.5AS-09UR3SXE00Also listed as AS-09UW3SXE00B, AS-09UW3SXETG00G, AS-09UW3SXETG00P, AS-09UW3SXETG00Non-ducted, up to 1.5 tons | beats 96% · 18.0YMKE60BNJMFMO-XDucted, 5 tons and up |
| EER2 | beats 93% · 15.5AS-09UR3SXE00Also listed as AS-09UW3SXE00B, AS-09UW3SXETG00G, AS-09UW3SXETG00P, AS-09UW3SXETG00Non-ducted, up to 1.5 tons | beats 100% · 16.7YVAHP048B21S*Also sold as Coleman CVAHP048B21SNon-ducted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 98% · 31,000 Btu/hAUWR-24U3SF2Ducted, 2 tons | beats 99% · 21,800 Btu/hDHS18CMB22SNon-ducted, up to 1.5 tons |