Skip to content

Hisense vs York heat pumps

Measured against models of the same size and duct type, Hisense scores higher on 4 of the 6 ratings. Hisense has 161 outdoor models, York has 229 outdoor models. They share hardware: 12 equipment families appear under both names.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Hisense and York on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Hisense scores higher on 4 of the 6 ratings.
  • Hisense
  • York
  • Other ranked manufacturers
HisenseYork

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHisenseYork
Efficiency index54%median — · 11th ranked54%median — · 14th ranked
COP at 5°F59%median 2.00 · 11th ranked67%median 2.16 · 2nd ranked
Capacity retention at 5°F61% (higher)median 77% · 6th ranked51% (higher)median 70% · 14th ranked
HSPF251% (higher)median 9.0 · 15th ranked44% (higher)median 8.0 · 20th ranked
SEER256% (higher)median 20.0 · 12th ranked40% (higher)median 15.2 · 26th ranked
EER246%median 11.7 · 20th ranked57%median 11.7 · 10th ranked
Heating capacity at 5°F57% (higher)median 18,000 Btu/h · 11th ranked53% (higher)median 20,000 Btu/h · 14th ranked
Outdoor models161229
AHRI certifications1,10994,251

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHisenseYork
CEE 2025 Tier 1 (Split ASHP)80.1%129 models52.8%121 models
CEE 2026 Tier 1 (Split ASHP)75.8%122 models52.8%121 models
CEE Advanced Tier (Split ASHP)7.5%12 models7.9%18 models
Xcel Energy Colorado cold-climate ASHP (2025)68.3%110 models38.9%89 models
DOE Cold Climate Heat Pump Challenge7.5%12 models7.9%18 models
ENERGY STAR Cold Climate55.3%89 models35.4%81 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 9 groups where both have models
  • Hisense
  • York
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHisenseYork
Ducted, up to 1.5 tons11 · index 55%22 · index 54%
Ducted, 2 tons14 · index 46%20 · index 49%
Ducted, 2.5–3 tons23 · index 57%59 · index 50%
Ducted, 3.5–4.5 tons28 · index 54%69 · index 49%
Ducted, 5 tons and up5 · index 70%13 · index 42%
Non-ducted, up to 1.5 tons70 · index 57%43 · index 62%
Non-ducted, 2 tons15 · index 48%16 · index 63%
Non-ducted, 2.5–3 tons15 · index 45%15 · index 53%
Non-ducted, 3.5–4.5 tons5 · index 49%5 · index 54%
Non-ducted, 5 tons and up1 · index 84%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHisenseCold-climate score, best modelYorkCold-climate score, best model
Ducted, up to 1.5 tons73.0(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models qualify · AHRI 21746540480.4(50 is the typical model of its size class) (higher)YPAS18BLFASDQ1with ducted air handler YPPIMB18UFA1DQ9 of 20 models qualify · AHRI 218694255
Ducted, 2 tons82.1(50 is the typical model of its size class)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH38 of 11 models qualify · AHRI 21480209690.2(50 is the typical model of its size class) (higher)HH824E2S11with ducted air handler D(A,C,E)36A4K+JMC12B2SN1+TDR12 of 22 models qualify · AHRI 218026253
Ducted, 2.5–3 tons87.9(50 is the typical model of its size class)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P17 of 23 models qualify · AHRI 21480209792.3(50 is the typical model of its size class) (higher)HH836E2S11with indoor coil D(A,C,E)36A4K+TDR and furnace Z9ET080C16SMPS122 of 61 models qualify · AHRI 218350129
Ducted, 3.5–4.5 tons83.9(50 is the typical model of its size class)AUW-48U3TH1with ducted air handler AUH-48UX3TEH5Also listed as AOU-48U3T25U19 of 27 models qualify · AHRI 21746923590.3(50 is the typical model of its size class) (higher)HH860E2S11with ducted air handler DM59A4K+JMC20D2SN1+TDR18 of 67 models qualify · AHRI 218026269
Ducted, 5 tons and up88.6(50 is the typical model of its size class) (higher)AUWR-60U3TH5with ducted air handler AUH-60UX3TEH36 of 6 models qualify · AHRI 21480209863.4(50 is the typical model of its size class)PH9E60N00D212 of 13 models qualify · AHRI 218450295
Non-ducted, up to 1.5 tons90.9(50 is the typical model of its size class)AO-12U3T25Pwith ductless indoor unit AS-12U3THE25PAlso listed as AO-12U3T26P249 of 70 models qualify · AHRI 21772740491.6(50 is the typical model of its size class) (higher)YPAS18BLFASDQ1with ductless indoor unit YPCIB18UFA1DQ36 of 43 models qualify · AHRI 218694256
Non-ducted, 2 tons76.3(50 is the typical model of its size class)AUW-24U3TK1with ductless indoor unit ACT-24UR3TJA1Also listed as AOU-24U3T25U15 of 15 models qualify · AHRI 21601925396.3(50 is the typical model of its size class) (higher)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ13 of 16 models qualify · AHRI 218694257
Non-ducted, 2.5–3 tons92.7(50 is the typical model of its size class)AVW-36F3DAH212 of 15 models qualify · AHRI 21661824897.5(50 is the typical model of its size class) (higher)YPAS30BLFASDQ1with ductless indoor unit YPCIB30UFA1DQ11 of 15 models qualify · AHRI 218694248
Non-ducted, 3.5–4.5 tons94.6(50 is the typical model of its size class) (higher)AVW-48F3DAH24 of 5 models qualify · AHRI 21661825159.1(50 is the typical model of its size class)YPAS48BUFASDQ1with ductless indoor unit YPPFCB48UFA1DQ3 of 5 models qualify · AHRI 218696687
Non-ducted, 5 tons and up98.2(50 is the typical model of its size class)AVW-60F3DAH21 of 1 models qualify · AHRI 216618254No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHisenseAll-around score, best modelYorkAll-around score, best model
Ducted, up to 1.5 tons67.4(50 is the typical model of its size class)AUW-24U3TK1with ducted air handler AUH-18UX3TFH5Also listed as AOU-24U3T25U14 of 14 models have all five ratings · AHRI 21746540480.3(50 is the typical model of its size class) (higher)YPAS12BLFASDQ1with ducted air handler YPPIMB12UFA1DQ21 of 21 models have all five ratings · AHRI 218694251
Ducted, 2 tons79.5(50 is the typical model of its size class) (higher)AUWR-24U3TK5with ducted air handler AUH-24UX3TDH311 of 11 models have all five ratings · AHRI 21480209677.6(50 is the typical model of its size class)HH824E2S11with ducted air handler D(A,C,E)36A4K+JME08B2SN1+TDR25 of 25 models have all five ratings · AHRI 218026254
Ducted, 2.5–3 tons82.3(50 is the typical model of its size class)AUWR-36U3TW5with ducted air handler AUH-36UX3TDH3Also listed as AUWR-3624P, AOH-36U3T24P23 of 23 models have all five ratings · AHRI 21480209791.1(50 is the typical model of its size class) (higher)YPAS30BUFASDQ1with ducted air handler YPPIMB30UFA1DQ39 of 55 models have all five ratings · AHRI 218694240
Ducted, 3.5–4.5 tons82.6(50 is the typical model of its size class)AOH-48U3T24Pwith ducted air handler AE*L+DM60B4J+TDR28 of 28 models have all five ratings · AHRI 21726919785.7(50 is the typical model of its size class) (higher)HH860E2S11with ducted air handler D(A,C,E)60B3K+JMC20D2SN1+TDR44 of 68 models have all five ratings · AHRI 218014963
Ducted, 5 tons and up80.9(50 is the typical model of its size class) (higher)AUWR-6024Pwith ducted air handler AUH-6024Also listed as AOH-60U3T24P5 of 5 models have all five ratings · AHRI 21485537970.1(50 is the typical model of its size class)PH9E60N00D216 of 14 models have all five ratings · AHRI 218450295
Non-ducted, up to 1.5 tons94.5(50 is the typical model of its size class) (higher)AS-09UW3TBW00with ductless indoor unit AS-09UW3TBW**00Also listed as AO-09U3T25P, AO-09U3T26P270 of 70 models have all five ratings · AHRI 21673975289.2(50 is the typical model of its size class)YRACXJ12WHAAwith ductless indoor unit YRAKXJ12PHAA43 of 43 models have all five ratings · AHRI 218037193
Non-ducted, 2 tons61.6(50 is the typical model of its size class)AST-24UW3TKN00with ductless indoor unit AST-24UW3TKN**0015 of 15 models have all five ratings · AHRI 21408139984.5(50 is the typical model of its size class) (higher)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ16 of 16 models have all five ratings · AHRI 218694257
Non-ducted, 2.5–3 tons86.7(50 is the typical model of its size class) (higher)AVW-36F3DAH215 of 15 models have all five ratings · AHRI 21661824885.0(50 is the typical model of its size class)YPAS30BUFASDQ1with ductless indoor unit YPCIB30UFA1DQ15 of 15 models have all five ratings · AHRI 218694244
Non-ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class) (higher)AVW-48F3DAH25 of 5 models have all five ratings · AHRI 21661825160.5(50 is the typical model of its size class)YPAS48BUFASDQ1with ductless indoor unit YPCIB48UFA1DQ5 of 5 models have all five ratings · AHRI 218694246
Non-ducted, 5 tons and up83.5(50 is the typical model of its size class)AVW-60F3DAH21 of 1 models have all five ratings · AHRI 216618254No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHisenseYork
COP at 5°Fbeats 100% · 2.53AST-18UW3RXW00Also listed as AO-18U3R25ENon-ducted, up to 1.5 tonsbeats 100% · 3.55UPC24CN23STG1Ducted, 2 tons
Capacity retention at 5°Fbeats 100% · 100%AVW-60F3DAH2Ducted, 5 tons and upbeats 100% · 123%YRACXJ24WHBANon-ducted, 2 tons
HSPF2beats 99% · 10.1AVW-60F3DAH2Ducted, 5 tons and upbeats 100% · 12.0YPAS30BUFASDQ1Non-ducted, 2.5–3 tons
SEER2beats 99% · 32.0AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tonsbeats 100% · 22.0YH960E2C11Also sold as Coleman XH960E2C11Ducted, 3.5–4.5 tons
EER2beats 100% · 18.4AS-09UW3TBW00Also listed as AO-09U3T25P, AO-09U3T26P2Non-ducted, up to 1.5 tonsbeats 99% · 14.4YPAS36BLFASDQ1Non-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 100% · 63,000 Btu/hAVW-60F3DAH2Ducted, 5 tons and upbeats 100% · 23,000 Btu/hYRACXJ18WHAAAlso listed as YRACXJ18WHBANon-ducted, up to 1.5 tons

More comparisons