HITACHI vs KADEN heat pumps

Measured against models of the same size and duct type, HITACHI scores higher on 4 of the 6 ratings. HITACHI has 27 outdoor models, KADEN has 24 outdoor models. HITACHI and KADEN have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
HITACHI and KADEN on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, HITACHI scores higher on 4 of the 6 ratings.
  • HITACHI
  • KADEN
  • Other ranked manufacturers
HITACHIKADEN

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHITACHIKADEN
Efficiency index58%median —58%median —
COP at 5°F72% (higher)median 2.2552% (higher)median 2.00
Capacity retention at 5°F57% (higher)median 76%41% (higher)median 65%
HSPF265%median 9.869%median 9.3
SEER250%median 20.074%median 19.3
EER253% (higher)median 12.549% (higher)median 10.9
Heating capacity at 5°F49% (higher)median 14,500 Btu/h44% (higher)median 18,250 Btu/h
Outdoor models2724
AHRI certifications4737

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHITACHIKADEN
CEE 2025 Tier 1 (Split ASHP)74.1%20 models66.7%16 models
CEE 2026 Tier 1 (Split ASHP)74.1%20 models54.2%13 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)66.7%18 models25%6 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate14.8%4 models25%6 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • HITACHI
  • KADEN
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsNon-ducted, 5 tons and up2.1032 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHITACHIKADEN
Ducted, up to 1.5 tons4 · index 50%3 · index 42%
Ducted, 2 tons2 · index 56%2 · index 52%
Ducted, 2.5–3 tons3 · index 71%6 · index 52%
Ducted, 3.5–4.5 tons3 · index 66%4 · index 55%
Ducted, 5 tons and upNone2 · index 42%
Non-ducted, up to 1.5 tons15 · index 57%7 · index 73%
Non-ducted, 2 tons5 · index 57%1 · index 78%
Non-ducted, 2.5–3 tons4 · index 52%2 · index 69%
Non-ducted, 3.5–4.5 tons2 · index 60%2 · index 49%
Non-ducted, 5 tons and up1 · index 69%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHITACHICold-climate score, best modelKADENCold-climate score, best model
Ducted, up to 1.5 tons55.9(50 is the typical model of its size class) (higher)RAS-1.0PNNBDH1with ducted air handler RPIL-1.0PNN1DH2 of 4 models qualify · AHRI 20675085252.0(50 is the typical model of its size class)KO-PS218HP-2AAMA1 of 3 models qualify · AHRI 211793561
Ducted, 2 tons64.8(50 is the typical model of its size class) (higher)RAS-3.0PNNBDH1with ducted air handler RPIM-3.0PNN1DH1 of 2 models qualify · AHRI 20675085862.9(50 is the typical model of its size class)KO-UUS24HP-2AAMAwith ducted air handler KI-UUS24AHP-2AAMAAlso listed as KO-UUX24HP-2AAMA2 of 2 models qualify · AHRI 211793549
Ducted, 2.5–3 tons78.1(50 is the typical model of its size class)RAS-4.0PNNBDH1with ducted air handler RPIM-4.0PNN1DH2 of 3 models qualify · AHRI 206750860None on this board (0 of 6 models qualify)
Ducted, 3.5–4.5 tonsNone on this board (0 of 3 models qualify)None on this board (0 of 4 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons81.1(50 is the typical model of its size class)RAC-SH09WHLAEwith ductless indoor unit RAS-SH09RHLAE13 of 15 models qualify · AHRI 20690717289.3(50 is the typical model of its size class) (higher)KO-PSX06HP-2AAMAwith ductless indoor unit KI-PSX06WM-2AAMA2 of 7 models qualify · AHRI 213265556
Non-ducted, 2 tons76.3(50 is the typical model of its size class) (higher)RAC-PH24WHLAEwith ductless indoor unit RAS-PH24PHLAE3 of 5 models qualify · AHRI 20720048360.4(50 is the typical model of its size class)KO-PSX24HP-2AAMAwith ductless indoor unit KI-PSX24WM-2AAMA1 of 1 models qualify · AHRI 211793559
Non-ducted, 2.5–3 tons77.2(50 is the typical model of its size class)RAS-4.0PNNBDH1with ductless indoor unit RCI-4.0PNN1DH3 of 4 models qualify · AHRI 206750859None on this board (0 of 2 models qualify)
Non-ducted, 3.5–4.5 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 2 models qualify)
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHITACHIAll-around score, best modelKADENAll-around score, best model
Ducted, up to 1.5 tons57.7(50 is the typical model of its size class)RAS-1.0PNNBDH1with ducted air handler RPIL-1.0PNN1DH3 of 4 models have all five ratings · AHRI 20675085259.4(50 is the typical model of its size class) (higher)KO-PS218HP-2AAMA3 of 3 models have all five ratings · AHRI 211793561
Ducted, 2 tons55.8(50 is the typical model of its size class) (higher)RAS-3.0PNNBDH1with ducted air handler RPIM-3.0PNN1DH1 of 2 models have all five ratings · AHRI 20675085852.0(50 is the typical model of its size class)KO-UUS24HP-2AAMAwith ducted air handler KI-UUS24AHP-2AAMAAlso listed as KO-UUX24HP-2AAMA2 of 2 models have all five ratings · AHRI 211793549
Ducted, 2.5–3 tons74.3(50 is the typical model of its size class)HVAHP036B21S*2 of 3 models have all five ratings · AHRI 20399497575.4(50 is the typical model of its size class) (higher)KO-PS327HP-2AAMA6 of 6 models have all five ratings · AHRI 211793564
Ducted, 3.5–4.5 tons77.8(50 is the typical model of its size class) (higher)HVAHP048B21S*2 of 3 models have all five ratings · AHRI 20399497663.5(50 is the typical model of its size class)KO-PS548HP-2AAMA4 of 4 models have all five ratings · AHRI 211793568
Ducted, 5 tons and upNo models in this size class41.7(50 is the typical model of its size class)KO-UUS60HP-2AAMAwith ducted air handler KI-UUS60AHU-2AAMAAlso listed as KO-UUX60HP-2AAMA2 of 2 models have all five ratings · AHRI 211793553
Non-ducted, up to 1.5 tons72.1(50 is the typical model of its size class)RAC-SH09WHLAEwith ductless indoor unit RAS-SH09RHLAE14 of 15 models have all five ratings · AHRI 20690717292.0(50 is the typical model of its size class) (higher)KO-PSX06HP-2AAMAwith ductless indoor unit KI-PSX06WM-2AAMA7 of 7 models have all five ratings · AHRI 213265556
Non-ducted, 2 tons73.1(50 is the typical model of its size class)RAC-PH24WHLAEwith ductless indoor unit RAS-PH24PHLAE4 of 5 models have all five ratings · AHRI 20720048377.5(50 is the typical model of its size class) (higher)KO-PSX24HP-2AAMAwith ductless indoor unit KI-PSX24WM-2AAMA1 of 1 models have all five ratings · AHRI 211793559
Non-ducted, 2.5–3 tons74.6(50 is the typical model of its size class)HVAHP036B21S*3 of 4 models have all five ratings · AHRI 20399496978.2(50 is the typical model of its size class) (higher)KO-PS327HP-2AAMA2 of 2 models have all five ratings · AHRI 211793563
Non-ducted, 3.5–4.5 tons67.0(50 is the typical model of its size class) (higher)HVAHP048B21S*1 of 2 models have all five ratings · AHRI 20399497056.1(50 is the typical model of its size class)KO-PS548HP-2AAMA2 of 2 models have all five ratings · AHRI 211793567
Non-ducted, 5 tons and up68.5(50 is the typical model of its size class)HVAHP060B21S*1 of 1 models have all five ratings · AHRI 203994965No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHITACHIKADEN
COP at 5°Fbeats 99% · 2.30RAC-EH24WHLAENon-ducted, 2 tonsbeats 97% · 2.39KO-PSX12HP-2AAMANon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 133%RAC-PH09WHLAENon-ducted, up to 1.5 tonsbeats 92% · 107%KO-PSX06HP-2AAMANon-ducted, up to 1.5 tons
HSPF2beats 98% · 10.0HVAHP048B21S*Ducted, 3.5–4.5 tonsbeats 98% · 13.6KO-PSX06HP-2AAMANon-ducted, up to 1.5 tons
SEER2beats 93% · 23.1HVAHP048B21S*Non-ducted, 3.5–4.5 tonsbeats 99% · 24.6KO-PS327HP-2AAMANon-ducted, 2.5–3 tons
EER2beats 100% · 16.7HVAHP048B21S*Non-ducted, 3.5–4.5 tonsbeats 97% · 14.0KO-PSX24HP-2AAMANon-ducted, 2 tons
Heating capacity at 5°Fbeats 99% · 23,000 Btu/hRAC-PH18WHLAENon-ducted, up to 1.5 tonsbeats 79% · 13,100 Btu/hKO-PSX18HP-2AAMANon-ducted, up to 1.5 tons

More comparisons