Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
HITACHI vs Senville: heat pump ratings compared
Against heat pumps of the same size and type, a typical HITACHI model beats 58% and a typical Senville model 61%. Senville rates slightly higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
HITACHI
58%
of similar heat pumps beaten by its typical model
Above average27 models listed
Senville
61%
of similar heat pumps beaten by its typical model
Well above average27 models listed
- Efficiency on a 5°F dayCOP at 5°FHITACHI: Beats 72%Senville: Beats 44%
- Heating power kept at 5°FCapacity at 5°F vs 47°FHITACHI: Beats 57%Senville: Beats 60%
- Winter-long heating efficiencyHSPF2HITACHI: Beats 65%Senville: Beats 67%
- Summer-long cooling efficiencySEER2HITACHI: Beats 50%Senville: Beats 67%
- Hot-day cooling efficiencyEER2HITACHI: Beats 53%Senville: Beats 56%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- HITACHI
- 74%
- Senville
- 70%
Xcel CC
- HITACHI
- 67%
- Senville
- 44%
CEE Advanced
- HITACHI
- 0%
- Senville
- 4%
ENERGY STAR CC
- HITACHI
- 15%
- Senville
- 52%
Top cold-climate picks, ducted up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
HITACHI
- 1RAS-1.0PNNBDH1with ducted air handler RPIL-1.0PNN1DHHITACHI1 ton · 9,000 Btu/h · DuctedKeeps 79% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 79% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.0 (HSPF2)
- Below the middle
- 2RAS-2.0PNNBDH1with ducted air handler RPIL-2.0PNN1DHHITACHI1.5 tons · 18,000 Btu/h · DuctedKeeps 72% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
Senville
- 1SENA/09HF/OQwith ducted air handler SENA/09HF/IDSenville1 ton · 9,000 Btu/h · DuctedKeeps 108% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 108% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 12.0 (HSPF2)
- Top 10%
- 2SENA/12HF/OQwith ducted air handler SENA/12HF/IDSenville1 ton · 12,000 Btu/h · DuctedKeeps 97% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 97% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.96 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 3SENA/18HF/MOQSenville1.5 tons · 18,000 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.8 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view